User Manual
Page 48
... GND DSR (DCE side ready) RTS (Ready to send) CTS (Clear to send) No connection External Control Codes (Reference) FUNCTION Power ON OFF CODE DATA 9FH 80H 60H 4EH 00H CDH 9FH 80H 60H 4FH 00H CEH Input Switch Video1 (BNC) Video2 (RCA...the plasma monitor by external equipment. Use a crossed (reverse) cable. External Control Application These specifications cover the communications control of the External Control Codes if needed. 12345 678 9 Communication Parameters (1) Communication system Asynchronous (2) Interface RS-232C (3) Baud rate 9600 bps (4) Data length 8 bits ...
... GND DSR (DCE side ready) RTS (Ready to send) CTS (Clear to send) No connection External Control Codes (Reference) FUNCTION Power ON OFF CODE DATA 9FH 80H 60H 4EH 00H CDH 9FH 80H 60H 4FH 00H CEH Input Switch Video1 (BNC) Video2 (RCA...the plasma monitor by external equipment. Use a crossed (reverse) cable. External Control Application These specifications cover the communications control of the External Control Codes if needed. 12345 678 9 Communication Parameters (1) Communication system Asynchronous (2) Interface RS-232C (3) Baud rate 9600 bps (4) Data length 8 bits ...
User Manual
Page 56
2) Connector on the external equipment side: Serial port (RS-232C) connector. Communication Parameters (1) Communication system (2) Interface (3) Baud rate (4) Data length (5) Parity (6) Stop bit (7) Communication code Asynchronous RS-232C 9600 bps 8 bits Odd 1 bit Hex 3 See the specifications of the equipment that each pair of connector and the pin assignment. 3) Wiring ...
2) Connector on the external equipment side: Serial port (RS-232C) connector. Communication Parameters (1) Communication system (2) Interface (3) Baud rate (4) Data length (5) Parity (6) Stop bit (7) Communication code Asynchronous RS-232C 9600 bps 8 bits Odd 1 bit Hex 3 See the specifications of the equipment that each pair of connector and the pin assignment. 3) Wiring ...
User Manual
Page 96
MODEL NAME Request Function The external control equipment inquires the product code of the product code Received data 00 -09 80H 96H 10 -29 : : - (Hyphen) : (Blank) : A-Z Corresponding A B C DE F GHI J character Received data (H) 10 11 12 13 14 15 16 17 18 ... 25 26 27 28 29 If there are fewer than 12 characters in the product code, product code would be padded right with blanks. Example: If the product code of your plasma monitor is "PX-42VP4G", the returned codes would be as follows. DATA00:1FH, DATA01:27H, DATA02:80H, DATA03:04H, DATA04:02H, DATA05...
MODEL NAME Request Function The external control equipment inquires the product code of the product code Received data 00 -09 80H 96H 10 -29 : : - (Hyphen) : (Blank) : A-Z Corresponding A B C DE F GHI J character Received data (H) 10 11 12 13 14 15 16 17 18 ... 25 26 27 28 29 If there are fewer than 12 characters in the product code, product code would be padded right with blanks. Example: If the product code of your plasma monitor is "PX-42VP4G", the returned codes would be as follows. DATA00:1FH, DATA01:27H, DATA02:80H, DATA03:04H, DATA04:02H, DATA05...
Installation Guide
Page 1
...-by 25.4. Visual Systems v2.5 Product Description Type: Plasma Display Resolution: 853x480 Aspect Ratio: 16:9 Color Correction: NEC CCF (Capsulated Color Filter, in panel) Screen Surface: 42VP4: Anti-Reflective 42VP4D: Anti-Glare Dimensions: 40"(W) x 24"(H) x 3.5"(D) Weight: 61.8 lbs Notes This document is not intended to... 30° Portrait 10° Max Tilt www.necvisualsystems.com 42VP4/42VP4D Page 1 of 11 Maximum Tilt Angles Below are in either normal aspect ratio with any local building codes. Any ceilings or walls must be in accordance with bars on the left or ...
...-by 25.4. Visual Systems v2.5 Product Description Type: Plasma Display Resolution: 853x480 Aspect Ratio: 16:9 Color Correction: NEC CCF (Capsulated Color Filter, in panel) Screen Surface: 42VP4: Anti-Reflective 42VP4D: Anti-Glare Dimensions: 40"(W) x 24"(H) x 3.5"(D) Weight: 61.8 lbs Notes This document is not intended to... 30° Portrait 10° Max Tilt www.necvisualsystems.com 42VP4/42VP4D Page 1 of 11 Maximum Tilt Angles Below are in either normal aspect ratio with any local building codes. Any ceilings or walls must be in accordance with bars on the left or ...
Installation Guide
Page 11
www.necvisualsystems.com 42VP4/42VP4D Page 11 of the cable to simplify cable connection. Control Codes Function Code Data POWER ON 9FH 80H 60H 4EH 00H CDH ...DFH 80H 60H C1H 01H 01H 82H OFF DFH 80H 60H C1H 01H 02H 83H NOTE: Contact your NEC rep for codes not listed. NOTE: Use a cross/reverse/null modem cable. Cable Connection Communication Protocol: Interface: RS...-232C Communication: Asynchronous Baud Rate: 9600 bps Data Length: 8 bits Parity: Odd Stop Bit: 1 bit Communication Code: Hex PC Control Connector (D-Sub 9P) To TxD of PC To RxD of PC To GND of PC 12 3 ...
www.necvisualsystems.com 42VP4/42VP4D Page 11 of the cable to simplify cable connection. Control Codes Function Code Data POWER ON 9FH 80H 60H 4EH 00H CDH ...DFH 80H 60H C1H 01H 01H 82H OFF DFH 80H 60H C1H 01H 02H 83H NOTE: Contact your NEC rep for codes not listed. NOTE: Use a cross/reverse/null modem cable. Cable Connection Communication Protocol: Interface: RS...-232C Communication: Asynchronous Baud Rate: 9600 bps Data Length: 8 bits Parity: Odd Stop Bit: 1 bit Communication Code: Hex PC Control Connector (D-Sub 9P) To TxD of PC To RxD of PC To GND of PC 12 3 ...