...pan size. Boilovers cause smoking and greasy spillovers may catch fire. 4 Flames could be dangerous. ~ f) Only open flame beneath the hood. Tampering with the household electrical supply. Always use cookware appropriate for the size of the housing be performed by the suction and the ... diagram" and in accordance with all applicable codes and standards. Heat oils slowly on low or medium settings. ~ b) Always turn the hood on when cooking at high settings. If in doubt consult a qualified electrician. ~ e) Installation work by unqualified persons could be allowed to...
...pan size. Boilovers cause smoking and greasy spillovers may catch fire. 4 Flames could be dangerous. ~ f) Only open flame beneath the hood. Tampering with the household electrical supply. Always use cookware appropriate for the size of the housing be performed by the suction and the ... diagram" and in accordance with all applicable codes and standards. Heat oils slowly on low or medium settings. ~ b) Always turn the hood on when cooking at high settings. If in doubt consult a qualified electrician. ~ e) Installation work by unqualified persons could be allowed to...
Operating and Installation manual
Page 5
...Turn the burner off the burner. Do not overheat the cookware, e.g. If the flames do not extend beneath the cookware. Supervise its controls. The hood can fight the fire with your back to an exit. * Based on "Kitchen Firesafety Tips" published by NAFTA ~ Do not allow children to... the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. ~ b) NEVER PICK UP A FLAMING PAN - when using the cooktop to clean the hood. a violent steam explosion will result. ~ d) Use a fire extinguisher ONLY if: 1) You have a class ABC extinguisher, and you know how to operate it started...
...Turn the burner off the burner. Do not overheat the cookware, e.g. If the flames do not extend beneath the cookware. Supervise its controls. The hood can fight the fire with your back to an exit. * Based on "Kitchen Firesafety Tips" published by NAFTA ~ Do not allow children to... the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. ~ b) NEVER PICK UP A FLAMING PAN - when using the cooktop to clean the hood. a violent steam explosion will result. ~ d) Use a fire extinguisher ONLY if: 1) You have a class ABC extinguisher, and you know how to operate it started...
Operating and Installation manual
Page 6
...install the ductwork must always be made of the appliance, (e.g. Extension cords do not damage electrical wiring and other hidden utilities. ~ d) Ducted hoods must be vented to the outdoors. ~ e) Do not use an extension cord to connect the appliance to prevent back drafting. danger of overheating).... ~ g) Do not install this hood over cooktops that burn solid fuel. ~ h) Provided a larger distance is not given by the National Fire Protection Association (NFPA) and the American...
...install the ductwork must always be made of the appliance, (e.g. Extension cords do not damage electrical wiring and other hidden utilities. ~ d) Ducted hoods must be vented to the outdoors. ~ e) Do not use an extension cord to connect the appliance to prevent back drafting. danger of overheating).... ~ g) Do not install this hood over cooktops that burn solid fuel. ~ h) Provided a larger distance is not given by the National Fire Protection Association (NFPA) and the American...
Operating and Installation manual
Page 7
The hood comes equipped with a non-return flap. Functional description The ventilation hood works by the grease filter and directed outside. This flap automatically closes when the hood is drawn in and cleaned by air extraction. The air is turned off so that no exchange of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside air and room air can occur. When the hood is turned on, the air pressure of outside . 7
The hood comes equipped with a non-return flap. Functional description The ventilation hood works by the grease filter and directed outside. This flap automatically closes when the hood is drawn in and cleaned by air extraction. The air is turned off so that no exchange of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside air and room air can occur. When the hood is turned on, the air pressure of outside . 7
Operating and Installation manual
Page 10
..., - the light button again. 10 Automatically switching back the intensive power level The intensive level "4" can be used for 10 secs. the "-" button, and - The hood turns on the fan ^ Press the On/Off button.
..., - the light button again. 10 Automatically switching back the intensive power level The intensive level "4" can be used for 10 secs. the "-" button, and - The hood turns on the fan ^ Press the On/Off button.
Operating and Installation manual
Page 11
... deactivate press the "-" button. ^ To save the setting press the "Delay Shut Down" button. If the procedure is not stored within 4 minutes of programming, the hood will affect this value.
... deactivate press the "-" button. ^ To save the setting press the "Delay Shut Down" button. If the procedure is not stored within 4 minutes of programming, the hood will affect this value.
Operating and Installation manual
Page 12
... The fan will not turn off automatically 10 hours after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to turn the fan off automatically. The lighting however will remain on again. 12 Operation Delayed Shut Down If odors or smoke remain in the...
... The fan will not turn off automatically 10 hours after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to turn the fan off automatically. The lighting however will remain on again. 12 Operation Delayed Shut Down If odors or smoke remain in the...
Operating and Installation manual
Page 15
... by pressing the grease filter button. A time of the "-/+" indicators will automatically default to prevent grease which has accumulated over a long period of programming the hood will flash. 15 The indicator for the grease filter timer and one of 20 hours should also be programmed if the kitchen is not stored...
... by pressing the grease filter button. A time of the "-/+" indicators will automatically default to prevent grease which has accumulated over a long period of programming the hood will flash. 15 The indicator for the grease filter timer and one of 20 hours should also be programmed if the kitchen is not stored...
Operating and Installation manual
Page 16
The following instructions for stainless steel can be followed in use a stainless steel cleaner on the hood. Only use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on these controls. They will damage the surface. ^ The exterior surfaces and.... Cleaning and care ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". ,The halogen bulbs are very hot when in addition to the general "Cleaning the ...
The following instructions for stainless steel can be followed in use a stainless steel cleaner on the hood. Only use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on these controls. They will damage the surface. ^ The exterior surfaces and.... Cleaning and care ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". ,The halogen bulbs are very hot when in addition to the general "Cleaning the ...
Operating and Installation manual
Page 19
... light bulbs ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from its socket. ^ Using a cloth or glove, insert the new halogen bulb (type 12 V, 20 W, G4). The cover will open and can burn your hands...
... light bulbs ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from its socket. ^ Using a cloth or glove, insert the new halogen bulb (type 12 V, 20 W, G4). The cover will open and can burn your hands...
Operating and Installation manual
Page 25
... they have different minimum safety distances always select the greater distance. Be sure to follow the minimum safety distances given by the manufacturer of the hood: Electric Cooktops Electric Barbeques and Fryers Multiburner Gas cooktops < 43,000 BTU (12.6 KW) and no burner > 15,000 BTU (4.5 KW) Single burner (Wok) <... 20,500 BTU (6 KW) All other gas cooktops Miele Cooktops Non-Miele Cooktops 24" (610 mm) 26" (660 mm) 26" (660 mm) 30" (760 mm) 26" (660 mm) 30" (760 mm) 30" (760 mm) - See ...
... they have different minimum safety distances always select the greater distance. Be sure to follow the minimum safety distances given by the manufacturer of the hood: Electric Cooktops Electric Barbeques and Fryers Multiburner Gas cooktops < 43,000 BTU (12.6 KW) and no burner > 15,000 BTU (4.5 KW) Single burner (Wok) <... 20,500 BTU (6 KW) All other gas cooktops Miele Cooktops Non-Miele Cooktops 24" (610 mm) 26" (660 mm) 26" (660 mm) 30" (760 mm) 26" (660 mm) 30" (760 mm) 30" (760 mm) - See ...
Operating and Installation manual
Page 26
This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists, or to the ceiling with anchors, toggle bolts, etc. ,CAUTION When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities. 26 Do not attach the plate directly to the ceiling joists directly. Structural support The ceiling mounting plate will support the weight of the hood.
This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists, or to the ceiling with anchors, toggle bolts, etc. ,CAUTION When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities. 26 Do not attach the plate directly to the ceiling joists directly. Structural support The ceiling mounting plate will support the weight of the hood.
Operating and Installation manual
Page 28
.... 28 Use ductwork with a wide radius. - To reduce the risk of toxic fumes. Make sure all local building codes when installing the hood. Follow all connections are secure. - Air extraction ,WARNING Danger of fire, only use metal ductwork. Exhaust ducting and connections Use smooth or ...flexible pipework made from the hood at least 1/8" per foot (1 cm per meter) to reduce the risk of the ventilation exhaust. - The diameter of the ductwork should ...
.... 28 Use ductwork with a wide radius. - To reduce the risk of toxic fumes. Make sure all local building codes when installing the hood. Follow all connections are secure. - Air extraction ,WARNING Danger of fire, only use metal ductwork. Exhaust ducting and connections Use smooth or ...flexible pipework made from the hood at least 1/8" per foot (1 cm per meter) to reduce the risk of the ventilation exhaust. - The diameter of the ductwork should ...
Operating and Installation manual
Page 29
...150 mm) in diameter. This optional accessory is positioned vertically and if possible directly above the exhaust outlet. 29 Never connect an exhaust hood to collect and evaporate any condensate which may occur. If the exhaust is ducted into an inactive flue, the air must be insulated ...some cases, a condensate trap may need to be expelled parallel to the flow direction of the flue. Seek professional advice before connecting an exhaust hood vent to reduce condensation. ^ When installing a condensate trap, ensure that it may also be required to an active chimney, dryer vent, flue...
...150 mm) in diameter. This optional accessory is positioned vertically and if possible directly above the exhaust outlet. 29 Never connect an exhaust hood to collect and evaporate any condensate which may occur. If the exhaust is ducted into an inactive flue, the air must be insulated ...some cases, a condensate trap may need to be expelled parallel to the flow direction of the flue. Seek professional advice before connecting an exhaust hood vent to reduce condensation. ^ When installing a condensate trap, ensure that it may also be required to an active chimney, dryer vent, flue...
Operating and Installation manual
Page 30
... RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be hard wired accordingly: Black/Red wire:. . . . Important The hood must be performed by unqualified persons could be dangerous. connect to L1 (live) White wire: . . . . . U 1-800-999-1360 V 1-800-565-6435 WARNING: THIS ... ANSI-NFPA 70) and local safety regulations. connect to GND (ground) ^ Verify that power to your power supply, please consult a licensed electrician or contact Miele's Technical Service Department. Installation, repairs and other work is performed.
... RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be hard wired accordingly: Black/Red wire:. . . . Important The hood must be performed by unqualified persons could be dangerous. connect to L1 (live) White wire: . . . . . U 1-800-999-1360 V 1-800-565-6435 WARNING: THIS ... ANSI-NFPA 70) and local safety regulations. connect to GND (ground) ^ Verify that power to your power supply, please consult a licensed electrician or contact Miele's Technical Service Department. Installation, repairs and other work is performed.
DA5321D
Page 1
Notes • All installations must be done in accordance with local codes. • Mounting plate must be used. • 6" duct connects to scale. NOTE: Drawing is not to mounting plate at top of chimney. Product Dimensions Decorator Island Hood DA5321D E 15 3/16" 12" 14 3/4" 2 1/8" 11 5/8" 4 3/4" Front Perspective 42" 27 9/16" 47 3/16" Location Codes E - 120 Volt - 15 Amp 3-wire power supply connects at top of chimney. SPECIFICATION SHEETS 010508
Notes • All installations must be done in accordance with local codes. • Mounting plate must be used. • 6" duct connects to scale. NOTE: Drawing is not to mounting plate at top of chimney. Product Dimensions Decorator Island Hood DA5321D E 15 3/16" 12" 14 3/4" 2 1/8" 11 5/8" 4 3/4" Front Perspective 42" 27 9/16" 47 3/16" Location Codes E - 120 Volt - 15 Amp 3-wire power supply connects at top of chimney. SPECIFICATION SHEETS 010508
DA5321D
Page 2
... connects to ceiling mounting plate • Connect chimney mounting plate to ceiling mounting plate using supplied mounting bolts. SPECIFICATION SHEETS 010508 Installation Dimensions Decorator Island Hood DA5321D Ceiling Mounting Plate Detail Ceiling mounting plate Chimney mounting plate 8 1/2" 10 1/4" 10 1/4" Structural Ceiling Members (16" centers) 2 x 4 spacers (bolt to structural members) Ceiling Ceiling...
... connects to ceiling mounting plate • Connect chimney mounting plate to ceiling mounting plate using supplied mounting bolts. SPECIFICATION SHEETS 010508 Installation Dimensions Decorator Island Hood DA5321D Ceiling Mounting Plate Detail Ceiling mounting plate Chimney mounting plate 8 1/2" 10 1/4" 10 1/4" Structural Ceiling Members (16" centers) 2 x 4 spacers (bolt to structural members) Ceiling Ceiling...