Installation Instructions
Page 3
... Massachusetts, the following installation instructions apply: I A flexible gas connector, when used, must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by a qualified installer, service agency, or the gas supplier. WARNING: FIRE OR EXPLOSION HAZARD Failure to light any appliance. • Do not touch any electrical switch; I Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use any other appliance...
... Massachusetts, the following installation instructions apply: I A flexible gas connector, when used, must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by a qualified installer, service agency, or the gas supplier. WARNING: FIRE OR EXPLOSION HAZARD Failure to light any appliance. • Do not touch any electrical switch; I Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use any other appliance...
Installation Instructions
Page 4
... vent installations) Leveling legs (4) Parts needed (not supplied with a pedestal or a stack kit. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. NOTE: Do not use leveling legs supplied with dryer if installing with dryer): ■■ Vent clamps ■■ Vent elbows and vent work Check that opens to 1" (25 mm) or hex-head socket wrench Wire stripper (direct wire installations) 4 Rubber washer 5' (1.52 m) inlet hose Parts package is located in dryer drum. Tools needed for all installations: Tools needed for gas...
... vent installations) Leveling legs (4) Parts needed (not supplied with a pedestal or a stack kit. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. NOTE: Do not use leveling legs supplied with dryer if installing with dryer): ■■ Vent clamps ■■ Vent elbows and vent work Check that opens to 1" (25 mm) or hex-head socket wrench Wire stripper (direct wire installations) 4 Rubber washer 5' (1.52 m) inlet hose Parts package is located in dryer drum. Tools needed for all installations: Tools needed for gas...
Installation Instructions
Page 5
... "Venting Requirements" before purchasing parts. The kit should be type SRD or SRDT and be at temperatures below 40°F (4°C). LOCATION REQUIREMENTS Check code requirements. DRYER DIMENSIONS Front view: Side view: Whirlpool® Models You will need : ■■ A location allowing for proper exhaust installation. See "Electrical Requirements." ■■ Floor must support dryer weight of dryer. ■■ The dryer must end in ring terminals or spade terminals with clothes dryers. If using a pedestal, you will need 18" (460 mm) to water...
... "Venting Requirements" before purchasing parts. The kit should be type SRD or SRDT and be at temperatures below 40°F (4°C). LOCATION REQUIREMENTS Check code requirements. DRYER DIMENSIONS Front view: Side view: Whirlpool® Models You will need : ■■ A location allowing for proper exhaust installation. See "Electrical Requirements." ■■ Floor must support dryer weight of dryer. ■■ The dryer must end in ring terminals or spade terminals with clothes dryers. If using a pedestal, you will need 18" (460 mm) to water...
Installation Instructions
Page 6
..., installation of gas dryers: ■■ Mobile Home Installation Hold-down Kit Part Number 346764 is installed, top and bottom air openings in your local building inspector. Openings (such as a nearby window) should also be at least twice as large as a dryer. Check code requirements. For further information, see "Assistance or Service" in your dealer. Custom under-counter installation: Mobile home - Additional installation requirements: This dryer is allowed for exhaust vent with a door...
..., installation of gas dryers: ■■ Mobile Home Installation Hold-down Kit Part Number 346764 is installed, top and bottom air openings in your local building inspector. Openings (such as a nearby window) should also be at least twice as large as a dryer. Check code requirements. For further information, see "Assistance or Service" in your dealer. Custom under-counter installation: Mobile home - Additional installation requirements: This dryer is allowed for exhaust vent with a door...
Installation Instructions
Page 7
... National Electrical Code requires a 4-wire power supply connection for 3-Wire Connection" in conformance with ring or spade terminals and UL listed strain relief. The neutral ground conductor is prohibited. The neutral conductor must be using a power supply cord: Use a UL Listed power supply cord kit marked for it is recommended that a qualified electrician determine that connect to the neutral conductor (white wire) within the dryer. If using and follow the instructions provided for use...
... National Electrical Code requires a 4-wire power supply connection for 3-Wire Connection" in conformance with ring or spade terminals and UL listed strain relief. The neutral ground conductor is prohibited. The neutral conductor must be using a power supply cord: Use a UL Listed power supply cord kit marked for it is recommended that a qualified electrician determine that connect to the neutral conductor (white wire) within the dryer. If using and follow the instructions provided for use...
Installation Instructions
Page 8
... a path of electric shock. Connect to be plugged into a standard 14-30R wall receptacle. Do not modify the plug provided with oper outlet ■■ 120 V, 60 Hz, AC-only, 15 or 20 A fused electrical supply is equipped with all local codes. The cord is recommended. A time-delay fuse or circuit breaker is 5 ft. (1.52 m) long. CANADA ONLY ELECTRICAL REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS It is properly grounded. If using a replacement power supply cord, it...
... a path of electric shock. Connect to be plugged into a standard 14-30R wall receptacle. Do not modify the plug provided with oper outlet ■■ 120 V, 60 Hz, AC-only, 15 or 20 A fused electrical supply is equipped with all local codes. The cord is recommended. A time-delay fuse or circuit breaker is 5 ft. (1.52 m) long. CANADA ONLY ELECTRICAL REQUIREMENTS GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS It is properly grounded. If using a replacement power supply cord, it...
Installation Instructions
Page 9
... gas supply line E. A. 3/8" flexible gas connector B. 3/8" pipe to reach for the type of your dryer has been converted to the dryer. The location should use with the B149.1, Natural Gas and Propane Installation Code. Option 2 (Alternate Method) Approved aluminum or copper tubing: ■■ Must include 1/8" NPT minimum plugged tapping accessible for use propane gas, 3/8" propane compatible copper tubing can result in the "Assistance or Service" section of gas in accordance with appropriate conversion...
... gas supply line E. A. 3/8" flexible gas connector B. 3/8" pipe to reach for the type of your dryer has been converted to the dryer. The location should use with the B149.1, Natural Gas and Propane Installation Code. Option 2 (Alternate Method) Approved aluminum or copper tubing: ■■ Must include 1/8" NPT minimum plugged tapping accessible for use propane gas, 3/8" propane compatible copper tubing can result in the "Assistance or Service" section of gas in accordance with appropriate conversion...
Installation Instructions
Page 10
... visible. DRYER GAS PIPE ■■ The gas pipe that complies with a listed flexible gas connector that comes out through the rear of the two dryer back corners. Place a carton corner post from dryer packaging under entire back edge of the burner Btu rating shown on the model/serial number plate is mounted on cardboard. 2. Stand the dryer up. Do not use a wrench to its final location. place...
... visible. DRYER GAS PIPE ■■ The gas pipe that complies with a listed flexible gas connector that comes out through the rear of the two dryer back corners. Place a carton corner post from dryer packaging under entire back edge of the burner Btu rating shown on the model/serial number plate is mounted on cardboard. 2. Stand the dryer up. Do not use a wrench to its final location. place...
Installation Instructions
Page 11
Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R). NOTE: If local codes do not permit connection of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down screw and terminal block cover. Remove terminal block cover Remove hold-down (D), and hold the two clamp sections (C) together. 11 Attach power supply cord strain relief...
Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R). NOTE: If local codes do not permit connection of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down screw and terminal block cover. Remove terminal block cover Remove hold-down (D), and hold the two clamp sections (C) together. 11 Attach power supply cord strain relief...
Installation Instructions
Page 12
... sure that the wire insulation on the power supply cord is required for mobile homes and where local codes do not permit the use of 3-wire connections. Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Connect ground wire 4-wire receptacle (NEMA type 14-30R) 4 prong plug Spade terminals with the dryer cabinet and be in a horizontal position. Prepare to "3-Wire Power Supply Cord Connection" on this...
... sure that the wire insulation on the power supply cord is required for mobile homes and where local codes do not permit the use of 3-wire connections. Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Connect ground wire 4-wire receptacle (NEMA type 14-30R) 4 prong plug Spade terminals with the dryer cabinet and be in a horizontal position. Prepare to "3-Wire Power Supply Cord Connection" on this...
Installation Instructions
Page 15
... dryer rear panel. Squeeze hooked ends together and tighten screws. Now go to "Venting Requirements." 3-Wire Direct Wire Connection Use where local codes permit connecting cabinet-ground conductor to connect neutral ground wire and neutral wire 5. Prepare your 3-wire cable for direct connection Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of remaining direct wire cable wires under green external ground conductor screw (A). Connect remaining wires Remove...
... dryer rear panel. Squeeze hooked ends together and tighten screws. Now go to "Venting Requirements." 3-Wire Direct Wire Connection Use where local codes permit connecting cabinet-ground conductor to connect neutral ground wire and neutral wire 5. Prepare your 3-wire cable for direct connection Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire (white or center wire) (C) of direct wire cable under center screw of remaining direct wire cable wires under green external ground conductor screw (A). Connect remaining wires Remove...
Installation Instructions
Page 16
... terminal block screw (B). Now go to "Venting Requirements." Connect remaining wires Place hooked ends of direct wire cable under outer terminal block screws (hooks facing right). Tighten screws. Prepare to an adequate ground. Remove center terminal block screw (B). 3. Connect neutral ground wire and neutral wire Place hooked end of neutral wire (white or center) (C) of remaining direct wire cable wires under center terminal block screw (B), hook facing right. Tighten screw. 4. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover...
... terminal block screw (B). Now go to "Venting Requirements." Connect remaining wires Place hooked ends of direct wire cable under outer terminal block screws (hooks facing right). Tighten screws. Prepare to an adequate ground. Remove center terminal block screw (B). 3. Connect neutral ground wire and neutral wire Place hooked end of neutral wire (white or center) (C) of remaining direct wire cable wires under center terminal block screw (B), hook facing right. Tighten screw. 4. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover...
Installation Instructions
Page 17
Install a shut-off valve 1. A recommended connection is used to connect dryer to supply line type, size, and location. 3. Connect gas supply to propane, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column. If flexible metal tubing is shown. Do not use pipe-joint compound resistant to dryer. Bubbles will show a leak. MAKE GAS CONNECTION (Gas models only) WARNING 2. Open shut-off valve. Open valve Open shut-off valve in death, explosion, or fire. Examples of...
Install a shut-off valve 1. A recommended connection is used to connect dryer to supply line type, size, and location. 3. Connect gas supply to propane, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column. If flexible metal tubing is shown. Do not use pipe-joint compound resistant to dryer. Bubbles will show a leak. MAKE GAS CONNECTION (Gas models only) WARNING 2. Open shut-off valve. Open valve Open shut-off valve in death, explosion, or fire. Examples of...
Installation Instructions
Page 18
... not install in final dryer location. ■■ Remove excess to avoid sagging and kinking that may be used. ■■ Do not use an exhaust hood with a magnetic latch. Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in enclosed walls, ceilings, or floors. ■■ The total length should cap the vent to...
... not install in final dryer location. ■■ Remove excess to avoid sagging and kinking that may be used. ■■ Do not use an exhaust hood with a magnetic latch. Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in enclosed walls, ceilings, or floors. ■■ The total length should cap the vent to...
Installation Instructions
Page 19
... drying times and increased energy usage. Exhaust hood E. A. Wall D. If you prefer, you may contact your local dealer. Left- Exhaust outlet WARNING Fire Hazard Cover unused exhaust holes with a manufacturer's exhaust cover kit. Terminate exhaust vent outside. Dryer B. Failure to follow these instructions can be securely fastened to connect elbows H. Standard rear offset exhaust installation B. Determine vent length and elbows needed for mobile homes: Exhaust vent must be converted to exhaust out the right side, left side (all models...
... drying times and increased energy usage. Exhaust hood E. A. Wall D. If you prefer, you may contact your local dealer. Left- Exhaust outlet WARNING Fire Hazard Cover unused exhaust holes with a manufacturer's exhaust cover kit. Terminate exhaust vent outside. Dryer B. Failure to follow these instructions can be securely fastened to connect elbows H. Standard rear offset exhaust installation B. Determine vent length and elbows needed for mobile homes: Exhaust vent must be converted to exhaust out the right side, left side (all models...
Installation Instructions
Page 20
.... (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Install Vent System 1. Avoid 90° turns. Use clamps to dryer location using straightest path possible. XXXXXXXXXX. Long Vent System Chart Number of 90° elbows Type of vent to secure vent, because they can catch...
.... (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Install Vent System 1. Avoid 90° turns. Use clamps to dryer location using straightest path possible. XXXXXXXXXX. Long Vent System Chart Number of 90° elbows Type of vent to secure vent, because they can catch...
Installation Instructions
Page 21
... hose and replace with additional 2/3 turn . Attach washer cold inlet hose to male end of "Y" connector. Turn cold water off and remove washer inlet hose. Then attach "Y" connector to other side of the 2 ft. (0.6 m) inlet hose. Attach long hose to the coupling can result. Do not use to the "Y" connector. Screw on coupling by hand until it is seated on the hoses for future reference. Damage to "Connect Vent." CONNECT INLET HOSE (STEAM MODEL...
... hose and replace with additional 2/3 turn . Attach washer cold inlet hose to male end of "Y" connector. Turn cold water off and remove washer inlet hose. Then attach "Y" connector to other side of the 2 ft. (0.6 m) inlet hose. Attach long hose to the coupling can result. Do not use to the "Y" connector. Screw on coupling by hand until it is seated on the hoses for future reference. Damage to "Connect Vent." CONNECT INLET HOSE (STEAM MODEL...
Installation Instructions
Page 23
..., use wrench to the need for levelness. If there is recommended to side. Do not select Air Only Temperature setting. This odor is common when heating element is first heated. Repeat from side to control the buildup of its first cycle. Electric Models: Plug into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit breaker has not tripped. • Dryer door...
..., use wrench to the need for levelness. If there is recommended to side. Do not select Air Only Temperature setting. This odor is common when heating element is first heated. Repeat from side to control the buildup of its first cycle. Electric Models: Plug into an outlet and/or electrical supply is connected. • Household fuse is intact and tight, or circuit breaker has not tripped. • Dryer door...
Installation Instructions
Page 24
... of Acument Intellectual Properties, LLC. 24 Using a Phillips screwdriver, remove middle screw in death or electrical shock. 3. Disconnect wiring. Tools needed: ALL DOORS: 2. Replace all parts and panels before servicing. Move the door strike 1. Disconnect wiring from the dryer door before proceeding. DOOR REVERSAL (OPTIONAL) The following instructions are registered trademarks of the dryer. Electrical Shock Hazard Disconnect power before operating. Remove door from dryer Min. 8" (203 mm) long TORX®, T20®, and T25...
... of Acument Intellectual Properties, LLC. 24 Using a Phillips screwdriver, remove middle screw in death or electrical shock. 3. Disconnect wiring. Tools needed: ALL DOORS: 2. Replace all parts and panels before servicing. Move the door strike 1. Disconnect wiring from the dryer door before proceeding. DOOR REVERSAL (OPTIONAL) The following instructions are registered trademarks of the dryer. Electrical Shock Hazard Disconnect power before operating. Remove door from dryer Min. 8" (203 mm) long TORX®, T20®, and T25...
Specification Sheet
Page 1
..., pockets and seams drier the first time.* Advanced Moisture Sensing Advanced Moisture Sensing monitors inside moisture and air temperatures to help evenly dry loads. For complete details, see Installation Instructions packed with Door Open 90° Maximum Vent Length Venting Direction Ventless Reference Material Install Guide Use & Care Guide Warranty Powder Coat Electric Side Swing Yes 10 Bulky Items Delicates Heavy Duty Normal Quick Dry Regular Timed Dry Towels Whites Wrinkle Control Control Lock Cycle Signal Wrinkle Prevent 38-1/8" x 27...
..., pockets and seams drier the first time.* Advanced Moisture Sensing Advanced Moisture Sensing monitors inside moisture and air temperatures to help evenly dry loads. For complete details, see Installation Instructions packed with Door Open 90° Maximum Vent Length Venting Direction Ventless Reference Material Install Guide Use & Care Guide Warranty Powder Coat Electric Side Swing Yes 10 Bulky Items Delicates Heavy Duty Normal Quick Dry Regular Timed Dry Towels Whites Wrinkle Control Control Lock Cycle Signal Wrinkle Prevent 38-1/8" x 27...