Module Installation Manual
Page 5
Item No. Description 1 StructureScan HD Black box module 1 4 pin power cable 1 Fuse, 3A Automotive Type 1 Fuse holder 2 Yellow Ethernet caps 1 Close end crimp connector 4 Phillips stainless steal screws (#8) 1 Warranty 1 This manual 1 Manual translations DVD Introduction | StructureScan HD Installation | 5 1 Introduction This document describes how to install the StructureScan™ HD black box module and connect the unit to transducers and...
Item No. Description 1 StructureScan HD Black box module 1 4 pin power cable 1 Fuse, 3A Automotive Type 1 Fuse holder 2 Yellow Ethernet caps 1 Close end crimp connector 4 Phillips stainless steal screws (#8) 1 Warranty 1 This manual 1 Manual translations DVD Introduction | StructureScan HD Installation | 5 1 Introduction This document describes how to install the StructureScan™ HD black box module and connect the unit to transducers and...
Module Installation Manual
Page 6
... broken On - Required tools and supplies 2 mm (5/64") Phillips screw Drill Drill Bit driver Pencil StructureScan HD Indicator lights LINK/ACT 1 2 3 SONAR POWER Ind. 1, 2 and 3 Sonar Power Status Description No Ethernet communication Off (cable unplugged, bad cable or remote unit not powered) Flashing yellow Ethernet communication is working Fast flashing Red/green Product in factory mode; Product...
... broken On - Required tools and supplies 2 mm (5/64") Phillips screw Drill Drill Bit driver Pencil StructureScan HD Indicator lights LINK/ACT 1 2 3 SONAR POWER Ind. 1, 2 and 3 Sonar Power Status Description No Ethernet communication Off (cable unplugged, bad cable or remote unit not powered) Flashing yellow Ethernet communication is working Fast flashing Red/green Product in factory mode; Product...
Module Installation Manual
Page 7
... to get the best use and performance from this product. For transducer cable length see diagram). 2 Installation and Wiring The StructureScan HD black box module connects between different electrical equipment, (see Spare parts and...cable runs necessary to connect the module to the appropriate Electromagnetic Compatibility (EMC) standards; Selecting mounting location When installing the module certain factors that could affect its operation should be considered. Installation and Wiring | StructureScan HD Installation | 7 The module conforms to the display unit and power...
... to get the best use and performance from this product. For transducer cable length see diagram). 2 Installation and Wiring The StructureScan HD black box module connects between different electrical equipment, (see Spare parts and...cable runs necessary to connect the module to the appropriate Electromagnetic Compatibility (EMC) standards; Selecting mounting location When installing the module certain factors that could affect its operation should be considered. Installation and Wiring | StructureScan HD Installation | 7 The module conforms to the display unit and power...
Module Installation Manual
Page 8
.... Wiring Refer to prevent moisture entering the connectors. Warning: Removing the transducer cable from its power source. If that cables exit sideways. HD Mounting the StructureScan HD module Preferably mount the StructureScan HD black box module on a vertical surface so that is powered on page 10. Secure cables and ensure to your display over an Ethernet network, either directly or...
.... Wiring Refer to prevent moisture entering the connectors. Warning: Removing the transducer cable from its power source. If that cables exit sideways. HD Mounting the StructureScan HD module Preferably mount the StructureScan HD black box module on a vertical surface so that is powered on page 10. Secure cables and ensure to your display over an Ethernet network, either directly or...
Module Installation Manual
Page 9
... the optional Y cable. On boats with the transducer. Alternatively the unit can be powered directly from the vessel's battery (B). +_ _ Power Control bus Fuse (1) A (3) (4) (2) (no connect) 12 V DC B (1) (3) (4) Switch (2) (no connect) + 12 V DC Pin/Item Color Signal 1 Black 12 V battery - 41 2 32 3 Blue NC Red 12V battery + 4 Yellow Ignition sense Installation and Wiring | StructureScan HD Installation | 9
... the optional Y cable. On boats with the transducer. Alternatively the unit can be powered directly from the vessel's battery (B). +_ _ Power Control bus Fuse (1) A (3) (4) (2) (no connect) 12 V DC B (1) (3) (4) Switch (2) (no connect) + 12 V DC Pin/Item Color Signal 1 Black 12 V battery - 41 2 32 3 Blue NC Red 12V battery + 4 Yellow Ignition sense Installation and Wiring | StructureScan HD Installation | 9
Module Installation Manual
Page 10
... it is recommended that the yellow power cable wire be powered off switch, allowing the module to be fitted with an optional on page 12. 10 | Installation and Wiring | StructureScan HD Installation To display unit A To display unit A LTW LTW B B LTW LTW LTW LTW PWR C or B Reference A B C Description Ethernet cable StructureScan Transducer cable StructureScan Y-cable (option) For part numbers, see...
... it is recommended that the yellow power cable wire be powered off switch, allowing the module to be fitted with an optional on page 12. 10 | Installation and Wiring | StructureScan HD Installation To display unit A To display unit A LTW LTW B B LTW LTW LTW LTW PWR C or B Reference A B C Description Ethernet cable StructureScan Transducer cable StructureScan Y-cable (option) For part numbers, see...
Module Installation Manual
Page 12
Description 000-10801-001 StructureScan HD module 032-0055-08 4 pin power cable Assessories Item Part no . 4 Spare parts and accessories Spare parts Item Part no . 000-10802-001 ...-0127-37 000-0124-70 Description StructureScan Skimmer mount transducer, including 6 m (20 ft) cable Transducer Extension cable, 3 m (10 ft) StructureScan Y-cable, 0.3 m (11.8") Ethernet cable, 1.8 m (6 ft) Ethernet cable, 4.6 m (15 ft) Ethernet cable, 7.6 m (25 ft) Ethernet cable, 15.2 m (50 ft) Kit of 4 replacement caps for connectors 12 | Spare Parts and Accessories | StructureScan HD Installation
Description 000-10801-001 StructureScan HD module 032-0055-08 4 pin power cable Assessories Item Part no . 4 Spare parts and accessories Spare parts Item Part no . 000-10802-001 ...-0127-37 000-0124-70 Description StructureScan Skimmer mount transducer, including 6 m (20 ft) cable Transducer Extension cable, 3 m (10 ft) StructureScan Y-cable, 0.3 m (11.8") Ethernet cable, 1.8 m (6 ft) Ethernet cable, 4.6 m (15 ft) Ethernet cable, 7.6 m (25 ft) Ethernet cable, 15.2 m (50 ft) Kit of 4 replacement caps for connectors 12 | Spare Parts and Accessories | StructureScan HD Installation
Transom Installation Manual
Page 3
..., you received this manual with the StructureScan HD module, a Power cable, fuse and fuse holder, StructureScan transducer, mounting bracket, 15 foot (4.5m) ethernet cable and a hardware kit. 1 Installation preparation Accessories If you will notice that some information in the document does not apply to the accessory. Hardware Mounting Kit (...
..., you received this manual with the StructureScan HD module, a Power cable, fuse and fuse holder, StructureScan transducer, mounting bracket, 15 foot (4.5m) ethernet cable and a hardware kit. 1 Installation preparation Accessories If you will notice that some information in the document does not apply to the accessory. Hardware Mounting Kit (...
Transom Installation Manual
Page 13
... Volts Voltage Input 10V - 17V Transmit Power WRMS: 500W WPK: 4000W Current Drain Max: .75A Inrush: 4.7A pk Typical: .60A Fuse Type External: 3A Fast Acting Automotive Blade Transducer Cable 20 feet (6m) Target Separation 1.5" (38.1mm) Transducer Frequency 455kHz Communication Ethernet Shared devices supported 3 Weight StructureScan module (1.8lbs) Transducer (1.9lbs) Transducer with...
... Volts Voltage Input 10V - 17V Transmit Power WRMS: 500W WPK: 4000W Current Drain Max: .75A Inrush: 4.7A pk Typical: .60A Fuse Type External: 3A Fast Acting Automotive Blade Transducer Cable 20 feet (6m) Target Separation 1.5" (38.1mm) Transducer Frequency 455kHz Communication Ethernet Shared devices supported 3 Weight StructureScan module (1.8lbs) Transducer (1.9lbs) Transducer with...
Transom Installation Manual
Page 14
... Power LED Power LED Power LED Power LED Power LED Ethernet LED Ethernet LED StructureScan LED Guide LED Status Definition Off Transducer not connected or cable/transducer is Flashing working Red/Green fast flashing Product in factory mode; ethernet slow flashing communication working (link/active light) 14 | no ethernet communication (cable unplugged or bad cable) No ethernet communication Off (cable...
... Power LED Power LED Power LED Power LED Power LED Ethernet LED Ethernet LED StructureScan LED Guide LED Status Definition Off Transducer not connected or cable/transducer is Flashing working Red/Green fast flashing Product in factory mode; ethernet slow flashing communication working (link/active light) 14 | no ethernet communication (cable unplugged or bad cable) No ethernet communication Off (cable...