TAC1 Manual
Page 2
... With a Telco Line Wiring the Unit Without a Telco Line Wiring a Gate Operator (Normally Open) Wiring an Auto-Call Sensor Wiring a Gate Operator (Normally Open) and a Door Strike Lock (Normally Open) Wiring a Gate Operator (Normally Open) and a Maglock (Normally Closed) Wiring a Door ...6 7 7 8 8 9 9 10 10 11 11 11 TESTING Test the Gate/Door Relays Test the Telephone Connections PROGRAMMING From the TAC1 Keypad Code Setup Code Operation From the Telephone Telephone Commands Program a Pre-Installed Liftmaster Receiver Quick Reference TAC1 MASTER CODE LIMITED WARRANTY 12 12 12 13-19 13 14 14 15...
... With a Telco Line Wiring the Unit Without a Telco Line Wiring a Gate Operator (Normally Open) Wiring an Auto-Call Sensor Wiring a Gate Operator (Normally Open) and a Door Strike Lock (Normally Open) Wiring a Gate Operator (Normally Open) and a Maglock (Normally Closed) Wiring a Door ...6 7 7 8 8 9 9 10 10 11 11 11 TESTING Test the Gate/Door Relays Test the Telephone Connections PROGRAMMING From the TAC1 Keypad Code Setup Code Operation From the Telephone Telephone Commands Program a Pre-Installed Liftmaster Receiver Quick Reference TAC1 MASTER CODE LIMITED WARRANTY 12 12 12 13-19 13 14 14 15...
TAC1 Manual
Page 3
See Power Wire Table Below From the door strike, maglock or gate operator From the strike power supply (if needed) From the Earth ground to processor board Residence and Telco phone lines From the processor board Between ...
See Power Wire Table Below From the door strike, maglock or gate operator From the strike power supply (if needed) From the Earth ground to processor board Residence and Telco phone lines From the processor board Between ...
TAC1 Manual
Page 7
...to contact the resident when a driveway sensor (or any device that provides a contact closure) is activated. 12 AUTO CALL NO (Normally Open) 7 Primary Gate Operator (Strike Open Input) Loop Detector Loop Sensor Notes about configuring Relays 1 and 2. EXIT 1 EXIT 2 AUTOCALL COM RELAY 2 RELAY 1 COM (Common)... wiring. • DO NOT overload wire connectors. Use ONLY one HOUSE TELCO wire per hole. INSTALLATION >> WIRING A GATE OPERATOR (NORMALLY OPEN) AND WIRING AN AUTO-CALL SENSOR WIRING A GATE OPERATOR (NORMALLY OPEN) The gate operator can be connected to Relay 1 or Relay 2.
...to contact the resident when a driveway sensor (or any device that provides a contact closure) is activated. 12 AUTO CALL NO (Normally Open) 7 Primary Gate Operator (Strike Open Input) Loop Detector Loop Sensor Notes about configuring Relays 1 and 2. EXIT 1 EXIT 2 AUTOCALL COM RELAY 2 RELAY 1 COM (Common)... wiring. • DO NOT overload wire connectors. Use ONLY one HOUSE TELCO wire per hole. INSTALLATION >> WIRING A GATE OPERATOR (NORMALLY OPEN) AND WIRING AN AUTO-CALL SENSOR WIRING A GATE OPERATOR (NORMALLY OPEN) The gate operator can be connected to Relay 1 or Relay 2.
TAC1 Manual
Page 8
...or Relay 2. RELAY 2 RELAY 1 NOTE: For DC power install a 1N4001 diode or equivalent. COM (Common) NO (Normally Open) COM (Common) WIRING A GATE OPERATOR (NORMALLY OPEN) & A MAGLOCK (NORMALLY CLOSED) The maglock can be connected to Relay 1 or Relay 2. See the Programming section for the maglock. EXIT ...) The door strike can be connected to simplify wiring. • DO NOT overload wire connectors. NO (Normally Open) DC Power Primary Gate Operator (Strike Open Input) Maglock NOTE: Install a 1N4001 diode or equivalent. NOTE: Do not use the unit's power supply for information...
...or Relay 2. RELAY 2 RELAY 1 NOTE: For DC power install a 1N4001 diode or equivalent. COM (Common) NO (Normally Open) COM (Common) WIRING A GATE OPERATOR (NORMALLY OPEN) & A MAGLOCK (NORMALLY CLOSED) The maglock can be connected to Relay 1 or Relay 2. See the Programming section for the maglock. EXIT ...) The door strike can be connected to simplify wiring. • DO NOT overload wire connectors. NO (Normally Open) DC Power Primary Gate Operator (Strike Open Input) Maglock NOTE: Install a 1N4001 diode or equivalent. NOTE: Do not use the unit's power supply for information...
TAC1 Manual
Page 12
...RELAY 2 Enter 4 digit Master Code + 2 (Key). Press the "Call" key on the processor board will blink during transmission. 3. The TAC1 will illuminate (Blue) to show activity when triggered. NOTE: Relay 2 status indicator LED will disconnect the call as soon as the relay is ...is pressed, the "Status" LED on the unit's keypad. The "1" Key indicates the Relay to be triggered. TEST THE TELEPHONE CONNECTIONS 1. The TAC1 will illuminate (Blue) to show activity when triggered. To test Relay 2 have someone answer the telephone and enter "*5" (Star + 5). TESTING >> TEST THE...
...RELAY 2 Enter 4 digit Master Code + 2 (Key). Press the "Call" key on the processor board will blink during transmission. 3. The TAC1 will illuminate (Blue) to show activity when triggered. NOTE: Relay 2 status indicator LED will disconnect the call as soon as the relay is ...is pressed, the "Status" LED on the unit's keypad. The "1" Key indicates the Relay to be triggered. TEST THE TELEPHONE CONNECTIONS 1. The TAC1 will illuminate (Blue) to show activity when triggered. To test Relay 2 have someone answer the telephone and enter "*5" (Star + 5). TESTING >> TEST THE...
TAC1 Manual
Page 16
Locate the receiver. NOTE: An error tone will be heard for each LiftMaster door or gate operator that the receiver memory is not pressed. Indicator Light Learn Button Repeat steps 2-4 for 3 consecutive activations only. If 9 (relay 1) or 5 (relay 2) is pressed, the TAC1 will blink 3 times indicating programming is in Learn Mode. 3. Within 30 seconds...
Locate the receiver. NOTE: An error tone will be heard for each LiftMaster door or gate operator that the receiver memory is not pressed. Indicator Light Learn Button Repeat steps 2-4 for 3 consecutive activations only. If 9 (relay 1) or 5 (relay 2) is pressed, the TAC1 will blink 3 times indicating programming is in Learn Mode. 3. Within 30 seconds...