TAC1 Manual
Page 3
... codes. The information is not responsible for suggested use only. DIMENSIONS 8-3/4" 3-3/4" 6" 3" 3/4" 3" 4-1/4" 2-3/4" 1/4" Power Supply: 12 Vac 20 VA or 16 Vdc 2.5A CARTON INVENTORY Unit (unlocked) (1) Key (1) 12 Volt AC 20 VA Plug-In UL Listed Power Transformer (1) Manual (1) 3 Check local building codes before installation. PROCESSOR BOARD WIRE TYPE RECOMMENDATIONS From the...
... codes. The information is not responsible for suggested use only. DIMENSIONS 8-3/4" 3-3/4" 6" 3" 3/4" 3" 4-1/4" 2-3/4" 1/4" Power Supply: 12 Vac 20 VA or 16 Vdc 2.5A CARTON INVENTORY Unit (unlocked) (1) Key (1) 12 Volt AC 20 VA Plug-In UL Listed Power Transformer (1) Manual (1) 3 Check local building codes before installation. PROCESSOR BOARD WIRE TYPE RECOMMENDATIONS From the...
TAC1 Manual
Page 11
... Code and store in place. MOUNT THE UNIT 1. Example: 1234. Slide the bottom of the unit onto the back panel. 3. Lock the unit with the key. Enter 4 digit Master Code. The Master Code should not be programmed for the unit's Master Code. NOTE: The star (*) button acts as a User Code. ... the board. SET THE UNIT MASTER CODE NOTE: DO NOT push the top of the unit onto the back panel before the bottom of the TAC1. INSTALLATION >> PLUG THE TRANSFORMER INTO THE OUTLET, MOUNT THE UNIT AND SET THE UNIT MASTER CODE PLUG THE TRANSFORMER INTO THE OUTLET Plug the transformer...
... Code and store in place. MOUNT THE UNIT 1. Example: 1234. Slide the bottom of the unit onto the back panel. 3. Lock the unit with the key. Enter 4 digit Master Code. The Master Code should not be programmed for the unit's Master Code. NOTE: The star (*) button acts as a User Code. ... the board. SET THE UNIT MASTER CODE NOTE: DO NOT push the top of the unit onto the back panel before the bottom of the TAC1. INSTALLATION >> PLUG THE TRANSFORMER INTO THE OUTLET, MOUNT THE UNIT AND SET THE UNIT MASTER CODE PLUG THE TRANSFORMER INTO THE OUTLET Plug the transformer...
TAC1 Manual
Page 12
...>> TEST THE GATE/DOOR RELAYS AND TEST THE TELEPHONE CONNECTIONS TEST GATE/DOOR RELAYS TEST RELAY 1 Enter 4 digit Master Code + 1 (Key). Press the "Call" key on the processor board will disconnect the call as soon as the relay is operating properly, then hang up the phone. 2. TEST THE ...NOTE: After the "Call" Button is activated. The "1" Key indicates the Relay to verify it is activated. 12 3 456 789 0 Call Button 12 The TAC1 will blink during transmission. 3. TEST RELAY 2 Enter 4 digit Master Code + 2 (Key). The TAC1 will disconnect the call as soon as the relay is ...
...>> TEST THE GATE/DOOR RELAYS AND TEST THE TELEPHONE CONNECTIONS TEST GATE/DOOR RELAYS TEST RELAY 1 Enter 4 digit Master Code + 1 (Key). Press the "Call" key on the processor board will disconnect the call as soon as the relay is operating properly, then hang up the phone. 2. TEST THE ...NOTE: After the "Call" Button is activated. The "1" Key indicates the Relay to verify it is activated. 12 3 456 789 0 Call Button 12 The TAC1 will blink during transmission. 3. TEST RELAY 2 Enter 4 digit Master Code + 2 (Key). The TAC1 will disconnect the call as soon as the relay is ...
TAC1 Manual
Page 13
... unit, 1 = Low, 2 = Medium and 3 = High. Default level is 0.5 seconds. 1. Enter the Master Code: ? ? ? ? 2. Enter the Master Code: ? ? ? ? 2. PROGRAMMING >> FROM THE TAC1 KEYPAD 12 3 GENERAL INSTRUCTION 456 789 0 NOTE: Use the STAR Key "*" to the house or complex. 1. CHANGE THE MASTER CODE 1. The unit will beep. 3. Default level is a stand alone system that...
... unit, 1 = Low, 2 = Medium and 3 = High. Default level is 0.5 seconds. 1. Enter the Master Code: ? ? ? ? 2. Enter the Master Code: ? ? ? ? 2. PROGRAMMING >> FROM THE TAC1 KEYPAD 12 3 GENERAL INSTRUCTION 456 789 0 NOTE: Use the STAR Key "*" to the house or complex. 1. CHANGE THE MASTER CODE 1. The unit will beep. 3. Default level is a stand alone system that...
TAC1 Manual
Page 16
... local telephone. Refer to the gate or door operator manual for each LiftMaster door or gate operator that receiver is successful. If 9 (relay 1) or 5 (relay 2) is pressed, the TAC1 will blink 3 times indicating programming is in Learn Mode. 3. Press "1" key on the receiver until the indicator light turns off indicating that the unit...
... local telephone. Refer to the gate or door operator manual for each LiftMaster door or gate operator that receiver is successful. If 9 (relay 1) or 5 (relay 2) is pressed, the TAC1 will blink 3 times indicating programming is in Learn Mode. 3. Press "1" key on the receiver until the indicator light turns off indicating that the unit...
TAC1 Manual
Page 17
...) + 024 + Relay Output Time (0000-8000 seconds) NOTE: Relay output time is ALWAYS 4 digits. DIRECT COMMANDS FROM THE TAC1 KEYPAD KEYSTROKES ACTION User Code + 1 Triggers Relay 1 User Code + 2 Triggers Relay 2 AUDIO FEEDBACK FROM THE TAC1: 1 Low Tone Beep = Failure 2 Two High Tone Beeps = Valid sequence 3 Low Tone Beep = Error or invalid sequence...
...) + 024 + Relay Output Time (0000-8000 seconds) NOTE: Relay output time is ALWAYS 4 digits. DIRECT COMMANDS FROM THE TAC1 KEYPAD KEYSTROKES ACTION User Code + 1 Triggers Relay 1 User Code + 2 Triggers Relay 2 AUDIO FEEDBACK FROM THE TAC1: 1 Low Tone Beep = Failure 2 Two High Tone Beeps = Valid sequence 3 Low Tone Beep = Error or invalid sequence...
TAC1 Manual
Page 18
... DESCRIPTION OF TASK NUMBER FACTORY PROGRAMMING PROCEDURE SETTING 0 Accepts Call From The Unit 0 (Also Extends Talk Time) *5 Triggers Relay 2 *5 *9 Triggers Relay 1 *9 NOTE: Use the STAR Key "*" to result in success (indicated by double high success tone). Stop and go keystrokes will result in a single string to cancel any input. NOTE: Keypad...
... DESCRIPTION OF TASK NUMBER FACTORY PROGRAMMING PROCEDURE SETTING 0 Accepts Call From The Unit 0 (Also Extends Talk Time) *5 Triggers Relay 2 *5 *9 Triggers Relay 1 *9 NOTE: Use the STAR Key "*" to result in success (indicated by double high success tone). Stop and go keystrokes will result in a single string to cancel any input. NOTE: Keypad...