... DRIVEN. *Cellular data or Wi-Fi® connection required. range: 90 ft. MANUAL DISCONNECT WHEN UNLOCKED ALLOWS GATE TO BE OPERAT E D M A NUA L LY. LMRRUL S505AL LMTBUL LMWEKITU AC SL585UL HEAVY-DUTY INDUSTRIAL SLIDE GATE OPERATOR PRODUCT H Reliable gear-driven slide gate operator for... SERVICING OPERATOR AND SAFEGUARDS WORKERS FROM HIGH-VOLTAGE POWER. max. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; PLUG-IN LOOP DETECTOR Prevents the gate from closing on Battery Backup. **Wireless kit...
... DRIVEN. *Cellular data or Wi-Fi® connection required. range: 90 ft. MANUAL DISCONNECT WHEN UNLOCKED ALLOWS GATE TO BE OPERAT E D M A NUA L LY. LMRRUL S505AL LMTBUL LMWEKITU AC SL585UL HEAVY-DUTY INDUSTRIAL SLIDE GATE OPERATOR PRODUCT H Reliable gear-driven slide gate operator for... SERVICING OPERATOR AND SAFEGUARDS WORKERS FROM HIGH-VOLTAGE POWER. max. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; PLUG-IN LOOP DETECTOR Prevents the gate from closing on Battery Backup. **Wireless kit...
SL585UL Product Guide - English
Page 2
... and Tr o u b l e s h o o t i n g PROGRAMMABLE AUXILIARY RELAYS - Supplied) SL585UL AC HEAVY-DUTY INDUSTRIAL SLIDE GATE OPERATOR POWER - 115/208/230VAC Single-Phase; 208/230/460/575VAC 3-Phase (575V... - c o m / S o l u t i o n - All Rights Reserved. LiftMaster, the LiftMaster logo, myQ and the myQ logo are registered trademarks of The Chamberlain Group, Inc. 300 Windsor Drive, Oak Brook,... per Hour - Maintains Accurate Gate Position Throughout Gate Travel, Even After Using Manual Disconnect MONITORED SAFETY INPUTS -3 Main Board, 3 Expansion Board SECURITY+ 2.0® ON-BOARD...
... and Tr o u b l e s h o o t i n g PROGRAMMABLE AUXILIARY RELAYS - Supplied) SL585UL AC HEAVY-DUTY INDUSTRIAL SLIDE GATE OPERATOR POWER - 115/208/230VAC Single-Phase; 208/230/460/575VAC 3-Phase (575V... - c o m / S o l u t i o n - All Rights Reserved. LiftMaster, the LiftMaster logo, myQ and the myQ logo are registered trademarks of The Chamberlain Group, Inc. 300 Windsor Drive, Oak Brook,... per Hour - Maintains Accurate Gate Position Throughout Gate Travel, Even After Using Manual Disconnect MONITORED SAFETY INPUTS -3 Main Board, 3 Expansion Board SECURITY+ 2.0® ON-BOARD...
Installation Manual
Page 1
... to 71403. Take a photo of the camera icon including the points ( ). 2. SL585ULTECH LiftMaster 300 Windsor Drive Oak Brook, IL 60523 Access installation and technical support guides or register this product 1. Model SL585UL ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR INSTALLATION MANUAL SL585101UL 1 HP, 120/208-240 Vac Single Phase SL585103UL 1 HP, 208-240...
... to 71403. Take a photo of the camera icon including the points ( ). 2. SL585ULTECH LiftMaster 300 Windsor Drive Oak Brook, IL 60523 Access installation and technical support guides or register this product 1. Model SL585UL ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR INSTALLATION MANUAL SL585101UL 1 HP, 120/208-240 Vac Single Phase SL585103UL 1 HP, 208-240...
Installation Manual
Page 2
...32 Loops 33 ADDITIONAL WIRING 33 SAMS wiring with relays not energized 33 Field Wiring 34 PROGRAMMING 35 Remote Controls (Not Provided 35 LiftMaster Internet Gateway (Not Provided 36 Erase All Codes 36 To Remove and Erase Monitored Entrapment Protection Devices 36 Constant Pressure Override (CPO 36... Alarm 43 Troubleshooting Chart 44 ACCESSORIES 46 REPAIR PARTS 47 WARRANTY 48 SAFETY Safety Symbol and Signal Word Review When you see this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate and/or the gate operator if you...
...32 Loops 33 ADDITIONAL WIRING 33 SAMS wiring with relays not energized 33 Field Wiring 34 PROGRAMMING 35 Remote Controls (Not Provided 35 LiftMaster Internet Gateway (Not Provided 36 Erase All Codes 36 To Remove and Erase Monitored Entrapment Protection Devices 36 Constant Pressure Override (CPO 36... Alarm 43 Troubleshooting Chart 44 ACCESSORIES 46 REPAIR PARTS 47 WARRANTY 48 SAFETY Safety Symbol and Signal Word Review When you see this manual and follow all safety instructions. • DO NOT attempt repair or service of your gate and/or the gate operator if you...
Installation Manual
Page 3
It is not moving. IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of INJURY or DEATH. Read the owner's manual. Pedestrians MUST use in a commercial location or building such as a factory or loading dock area or other restricted access locations not servicing the general public, ...
It is not moving. IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of INJURY or DEATH. Read the owner's manual. Pedestrians MUST use in a commercial location or building such as a factory or loading dock area or other restricted access locations not servicing the general public, ...
Installation Manual
Page 4
... an edge sensor: a. Pedestrians must be located and its function as the perimeter reachable l Screen Mesh by authorized personnel (e.g. A minimum of a gate system. Reference owner's manual regarding placement of non-contact sensor for entrapment protection functions shall be supplied with the vehicular gate during the entire path of travel of the...
... an edge sensor: a. Pedestrians must be located and its function as the perimeter reachable l Screen Mesh by authorized personnel (e.g. A minimum of a gate system. Reference owner's manual regarding placement of non-contact sensor for entrapment protection functions shall be supplied with the vehicular gate during the entire path of travel of the...
Installation Manual
Page 5
... 0.50 inches (12.7 mm) when other fixed stationary objects greater than the exceptions listed in ASTM F2200. An existing gate latch shall be disabled when a manually operated gate is less, to comply with this specification. All openings shall be designed, guarded, or screened from the gate frame shall not be required...
... 0.50 inches (12.7 mm) when other fixed stationary objects greater than the exceptions listed in ASTM F2200. An existing gate latch shall be disabled when a manually operated gate is less, to comply with this specification. All openings shall be designed, guarded, or screened from the gate frame shall not be required...
Installation Manual
Page 13
... of the gate. 2. Mount gate brackets to leave a maximum of 1" (2.5 cm) of chain slack for every 10' (3.1 m) of thumb is tightened. Locate and engage the manual release handle and lock it in line with the operator. 7.
... of the gate. 2. Mount gate brackets to leave a maximum of 1" (2.5 cm) of chain slack for every 10' (3.1 m) of thumb is tightened. Locate and engage the manual release handle and lock it in line with the operator. 7.
Installation Manual
Page 14
...for each entrapment zone. It is unique. Illustrations provided by DASMA Gate Systems Safety Guide l LiftMaster monitored external entrapment protection devices MUST be used with LiftMaster operators to protect in a position that ALL entrapment zones are protected with your entrapment protection device...protect anyone who may come near a moving gate. Step 3 Install Entrapment Protection Entrapment protection MUST be installed to the manual provided with an external monitored entrapment protection device, protecting both the open direction and one in a location up to function;...
...for each entrapment zone. It is unique. Illustrations provided by DASMA Gate Systems Safety Guide l LiftMaster monitored external entrapment protection devices MUST be used with LiftMaster operators to protect in a position that ALL entrapment zones are protected with your entrapment protection device...protect anyone who may come near a moving gate. Step 3 Install Entrapment Protection Entrapment protection MUST be installed to the manual provided with an external monitored entrapment protection device, protecting both the open direction and one in a location up to function;...
Installation Manual
Page 15
... monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors. This input will be wired to the specific entrapment protection device manual for more information.
... monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors. This input will be wired to the specific entrapment protection device manual for more information.
Installation Manual
Page 31
... 3 seconds before gate motion and remains energized during gate motion. The onboard alarm will turn on AUX RELAY 1 to ON 31 Cycle count displayed is manually tampered with barrier gate).
... 3 seconds before gate motion and remains energized during gate motion. The onboard alarm will turn on AUX RELAY 1 to ON 31 Cycle count displayed is manually tampered with barrier gate).
Installation Manual
Page 36
...the operator: 1. All remote control codes are present. Connect power to add devices. Use an internet enabled computer or smartphone to the LiftMaster Internet Gateway. 3. Within 30 seconds, when the gate is intended to temporarily override a fault in the entrapment protection system, in ...only in learn mode). Use an internet enabled computer or smartphone to travel are now erased. The LiftMaster Internet Gateway will pair to ONE gate operator (see the KPW5/KPW250 manual for three minutes. 6. Remove the entrapment protection device wires from the terminal block. 2. Enter a ...
...the operator: 1. All remote control codes are present. Connect power to add devices. Use an internet enabled computer or smartphone to the LiftMaster Internet Gateway. 3. Within 30 seconds, when the gate is intended to temporarily override a fault in the entrapment protection system, in ...only in learn mode). Use an internet enabled computer or smartphone to travel are now erased. The LiftMaster Internet Gateway will pair to ONE gate operator (see the KPW5/KPW250 manual for three minutes. 6. Remove the entrapment protection device wires from the terminal block. 2. Enter a ...
Installation Manual
Page 37
... servicing only to determine operator cycles. The heater keeps the gearbox and batteries at a suitable temperature when the outside temperature is manually tampered with by being pushed off of close limit. The thermostat MUST be different. RESIDENTIAL: One to OFF. close (timer ...vehicle access trumps security concerns COMMERCIAL: Business site where security (gate closed) is important INDUSTRIAL: Large business site where security is manually tampered with by being pushed off of close limit. In attempt to ON for the gate operator. Use with SAMS (Sequence ...
... servicing only to determine operator cycles. The heater keeps the gearbox and batteries at a suitable temperature when the outside temperature is manually tampered with by being pushed off of close limit. The thermostat MUST be different. RESIDENTIAL: One to OFF. close (timer ...vehicle access trumps security concerns COMMERCIAL: Business site where security (gate closed) is important INDUSTRIAL: Large business site where security is manually tampered with by being pushed off of close limit. In attempt to ON for the gate operator. Use with SAMS (Sequence ...
Installation Manual
Page 39
...l SAVE THESE INSTRUCTIONS. Pedestrians MUST use only lithium spray. DESCRIPTION TASK CHECK AT LEAST ONCE EVERY Entrapment Protection Devices Warning Signs Manual Disconnect Drive Chain and Sprockets Clutch System Brake System Gate Accessories Electrical Chassis Mounting Bolts Operator Check and test inherent (built into ...and replace if worn or broken, see page 5 Check all for proper operation Inspect all power to be performed by a LiftMaster professional. After adjusting the force or the limit of travel . Failure to the operator is NOT l Disconnect power at the operator. ...
...l SAVE THESE INSTRUCTIONS. Pedestrians MUST use only lithium spray. DESCRIPTION TASK CHECK AT LEAST ONCE EVERY Entrapment Protection Devices Warning Signs Manual Disconnect Drive Chain and Sprockets Clutch System Brake System Gate Accessories Electrical Chassis Mounting Bolts Operator Check and test inherent (built into ...and replace if worn or broken, see page 5 Check all for proper operation Inspect all power to be performed by a LiftMaster professional. After adjusting the force or the limit of travel . Failure to the operator is NOT l Disconnect power at the operator. ...
Installation Manual
Page 44
...active b. Close Entrapment Protection Device active a. Vehicle detector setup incorrectly b. Check all vehicle detector inputs for a "stuck on . Use manual disconnect, manually move to -Close. Gate must move a. a. a. b. POSSIBLE CAUSES a. Vehicle loop detector active c. b. Replace defective Exit loop ...not run . Gate closes, but motor does not run and diagnostic display not on " sensor e. c. Use manual disconnect, manually move to limit. Check all Entrapment Protection Device inputs for a "stuck on . Gate is active c. Stop button...
...active b. Close Entrapment Protection Device active a. Vehicle detector setup incorrectly b. Check all vehicle detector inputs for a "stuck on . Use manual disconnect, manually move to -Close. Gate must move a. a. a. b. POSSIBLE CAUSES a. Vehicle loop detector active c. b. Replace defective Exit loop ...not run . Gate closes, but motor does not run and diagnostic display not on " sensor e. c. Use manual disconnect, manually move to limit. Check all Entrapment Protection Device inputs for a "stuck on . Gate is active c. Stop button...
SL585UL SL595UL Three Phase Wiring Diagram
Page 1
...and preventing close and one in the electrical box for discharge of manual). • See manual prior to manual for OPEN cycle or EDGE SENSOR MAGLOCK (Optional) ACCESSORY POWER LOCKS...OPTIONAL ACCESSORY WIRING EXIT ACCESSORY POWER 24VAC 2.2 AMPS MAX Yellow Blue Black Red PRODUCT ID SL585UL - Purple 2 HP - CODE SEQUENCE NUMBER The first number shown is the most recent...Replace RPM assembly. 95 AC motor no action required. CODE COLOR KEY: LiftMaster System External Entrapment Protection Installed System Inherent Entrapment Protection Informational MEANING SOLUTION Main control...
...and preventing close and one in the electrical box for discharge of manual). • See manual prior to manual for OPEN cycle or EDGE SENSOR MAGLOCK (Optional) ACCESSORY POWER LOCKS...OPTIONAL ACCESSORY WIRING EXIT ACCESSORY POWER 24VAC 2.2 AMPS MAX Yellow Blue Black Red PRODUCT ID SL585UL - Purple 2 HP - CODE SEQUENCE NUMBER The first number shown is the most recent...Replace RPM assembly. 95 AC motor no action required. CODE COLOR KEY: LiftMaster System External Entrapment Protection Installed System Inherent Entrapment Protection Informational MEANING SOLUTION Main control...
SL585UL SL595UL 575V Three Phase Wiring Diagram
Page 1
...NOTE:The switch is connected to the chassis ground of each entrapment zone. Use ONLY LiftMaster approved entrapment protection devices (refer to the accessory page of manual). • See manual prior to DC control board accessory power only. FIRE DEPARTMENT OR EXIT LOOP SHADOW ...CONTROLS Jumper 3-BUTTON CONTROL STATION N.C. Wireless Second Operator Communication Check the second operator for shorts. 575V THREE PHASE WIRING DIAGRAM Models SL585UL and SL595UL To reduce the risk of INJURY or DEATH: • DISCONNECT power BEFORE installing or servicing operator. • Replace ...
...NOTE:The switch is connected to the chassis ground of each entrapment zone. Use ONLY LiftMaster approved entrapment protection devices (refer to the accessory page of manual). • See manual prior to DC control board accessory power only. FIRE DEPARTMENT OR EXIT LOOP SHADOW ...CONTROLS Jumper 3-BUTTON CONTROL STATION N.C. Wireless Second Operator Communication Check the second operator for shorts. 575V THREE PHASE WIRING DIAGRAM Models SL585UL and SL595UL To reduce the risk of INJURY or DEATH: • DISCONNECT power BEFORE installing or servicing operator. • Replace ...
SL585UL SL595UL Single Phase Wiring Diagram
Page 1
... Limit and Force Adjustment, and Obstruction Test. SINGLE PHASE WIRING DIAGRAM Models SL585UL and SL595UL To reduce the risk of INJURY or DEATH: • DISCONNECT...OPEN 8 RIGHT HANDING LOOPS CONTROLS 3-BUTTON CONTROL STATION Jumper N.C. CODE COLOR KEY: LiftMaster System External Entrapment Protection Installed System Inherent Entrapment Protection Informational MEANING SOLUTION 31 Main control ...connections. 60 entrapment protection devices Slide gate operators require a minimum of manual). • See manual prior to metal chassis CONTROL BOARD RPM & LIMITS ALA SET Limit...
... Limit and Force Adjustment, and Obstruction Test. SINGLE PHASE WIRING DIAGRAM Models SL585UL and SL595UL To reduce the risk of INJURY or DEATH: • DISCONNECT...OPEN 8 RIGHT HANDING LOOPS CONTROLS 3-BUTTON CONTROL STATION Jumper N.C. CODE COLOR KEY: LiftMaster System External Entrapment Protection Installed System Inherent Entrapment Protection Informational MEANING SOLUTION 31 Main control ...connections. 60 entrapment protection devices Slide gate operators require a minimum of manual). • See manual prior to metal chassis CONTROL BOARD RPM & LIMITS ALA SET Limit...
UL 325-Listed Gate Operators Guide
Page 3
...- - Door/Gate 700 lbs. For specifications and information on all our products, visit LiftMaster.com/TOTALPAS UL 325 LISTED GATE OPERATOR FEATURE CHART LMGTCTOOSB RESIDENTIAL GATE OPERATORS Model Number LA500PKGUL...(Main and Expansion Board) ELITE® SERIES AC COMMERCIAL/INDUSTRIAL GATE OPERATORS CSW200UL SL3000UL SL585UL SL595UL AC Commercial AC Commercial High-Traffic Swing Gate High-Traffic Slide Gate Operator Operator ...Up to 63 days Up to 24 days Up to 24 days Up to install manual for specific details) Solar Powered only 3 Years 25 ft. 800 lbs. 120 cycles...
...- - Door/Gate 700 lbs. For specifications and information on all our products, visit LiftMaster.com/TOTALPAS UL 325 LISTED GATE OPERATOR FEATURE CHART LMGTCTOOSB RESIDENTIAL GATE OPERATORS Model Number LA500PKGUL...(Main and Expansion Board) ELITE® SERIES AC COMMERCIAL/INDUSTRIAL GATE OPERATORS CSW200UL SL3000UL SL585UL SL595UL AC Commercial AC Commercial High-Traffic Swing Gate High-Traffic Slide Gate Operator Operator ...Up to 63 days Up to 24 days Up to 24 days Up to install manual for specific details) Solar Powered only 3 Years 25 ft. 800 lbs. 120 cycles...
UL 325-Listed Gate Operators Guide
Page 4
... INTERFERENCE AND OFFER EXTENDED RANGE. INHERENT REVERSING SENSOR DETECTS OBSTRUCTIONS AND REVERSES GATE WHEN CLOSING OR STOPS/REVERSES THE GATE WHEN OPENING. MANUAL DISCONNECT WHEN UNLOCKED ALLOWS GATE TO BE OPE NE D M A NU A LLY. max. max. EL1SS 828LM 210W/220W PRODUCT... TO SECURELY CONTROL AND MONITOR YOUR GATE OPERATOR FROM ANYWHERE. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; TOTAL SOLUTION ACCESSORIES: TELEPHONE INTERCOM AND ACCESS CONTROL SYSTEM Durable construction and secure access...
... INTERFERENCE AND OFFER EXTENDED RANGE. INHERENT REVERSING SENSOR DETECTS OBSTRUCTIONS AND REVERSES GATE WHEN CLOSING OR STOPS/REVERSES THE GATE WHEN OPENING. MANUAL DISCONNECT WHEN UNLOCKED ALLOWS GATE TO BE OPE NE D M A NU A LLY. max. max. EL1SS 828LM 210W/220W PRODUCT... TO SECURELY CONTROL AND MONITOR YOUR GATE OPERATOR FROM ANYWHERE. MONITORED WIRELESS EDGE KIT Low-energy Bluetooth® connection between a LiftMaster Monitored Resistive Edge and the gate operator; TOTAL SOLUTION ACCESSORIES: TELEPHONE INTERCOM AND ACCESS CONTROL SYSTEM Durable construction and secure access...