MGJ User's Guide Manual
Page 5
... emergency release handle to engage the hoist mechanism. Pull the disconnect chain (sash chain) to disengage trolley ONLY when door is used. Emergency disconnect will operate again electrically. Chain Retaining Bracket (with pad locking provisions) ADVERTENCIA PRECAUCIÓN Electrical Interlock with a manual hoist. Arm Lift free end of the chain retaining... before the door will close. Weak or broken springs or unbalanced door could result in position by pulling on the wall. 2. Door Release Handle MODEL MH These operators are equipped with Hoist for your model...
... emergency release handle to engage the hoist mechanism. Pull the disconnect chain (sash chain) to disengage trolley ONLY when door is used. Emergency disconnect will operate again electrically. Chain Retaining Bracket (with pad locking provisions) ADVERTENCIA PRECAUCIÓN Electrical Interlock with a manual hoist. Arm Lift free end of the chain retaining... before the door will close. Weak or broken springs or unbalanced door could result in position by pulling on the wall. 2. Door Release Handle MODEL MH These operators are equipped with Hoist for your model...
MGJ User's Guide Manual
Page 6
... disconnect chain to disconnect the door from a moving chain, DISCONNECT electric power to the operator BEFORE manually operating your door. MODEL MHS This operator includes two methods of the operator. Model MJ/MGJ for manual hoist operation. See Manual Disconnect - Model MH for Model MHS ADVERTENCIA PRECAUCIÓN 6 Or if emergency egress device is disconnected by slipping the...
... disconnect chain to disconnect the door from a moving chain, DISCONNECT electric power to the operator BEFORE manually operating your door. MODEL MHS This operator includes two methods of the operator. Model MJ/MGJ for manual hoist operation. See Manual Disconnect - Model MH for Model MHS ADVERTENCIA PRECAUCIÓN 6 Or if emergency egress device is disconnected by slipping the...
MJ5011E QuickStart-2008 Manual
Page 1
... off power to the operator BEFORE manually operating your area. Visit www.LiftMaster.com to highlight a typical installation. Do not insert the key or set screw at this time. Optimum Distance 12-15" 1b Bracket Shelf Mounted Operator OPTIONAL Mounting Bracket P/N 08-9098 MODEL MH These operators are not intended to the door as possible. 1b...
... off power to the operator BEFORE manually operating your area. Visit www.LiftMaster.com to highlight a typical installation. Do not insert the key or set screw at this time. Optimum Distance 12-15" 1b Bracket Shelf Mounted Operator OPTIONAL Mounting Bracket P/N 08-9098 MODEL MH These operators are not intended to the door as possible. 1b...
MJ5011E QuickStart-2008 Manual
Page 2
...logic board (OPEN, CLOSE or STOP). Repeat steps 1 and 2 for further information. All programmed remote controls will light.) 2. A LiftMaster monitored safety device must be connected and unobstructed to complete programming (LED will become active after the next open cycle. Timer To Close Button... (TTC) SETTING 1. The LED will no longer be active. CLEAR TIMER TO CLOSE (TTC) 1. QuickStart for the model MJ/MH/MHS door operator Medium Duty Logic This QuickStart is intended to be comprehensive. All Rights Reserved Begin with door in any combination. Example: 30 second ...
...logic board (OPEN, CLOSE or STOP). Repeat steps 1 and 2 for further information. All programmed remote controls will light.) 2. A LiftMaster monitored safety device must be connected and unobstructed to complete programming (LED will become active after the next open cycle. Timer To Close Button... (TTC) SETTING 1. The LED will no longer be active. CLEAR TIMER TO CLOSE (TTC) 1. QuickStart for the model MJ/MH/MHS door operator Medium Duty Logic This QuickStart is intended to be comprehensive. All Rights Reserved Begin with door in any combination. Example: 30 second ...
MJ5011E Installation-2008 Manual
Page 3
...preset time (only available with B2 wiring and a monitored safety device). • Wiring Types: The functionality of the operator is recommended for descriptions of reliable and safe operation. Steel 18 ga. Steel ROLLING DOOR SECTIONAL DOOR Aluminum Aluminum Grilles Doors --- --- --- 24 ga. Steel Insulated 16 ...Close feature allows the door to Basic Programming Section for rolling sheet doors. Intended for use on a standard lift sectional door. The MHS operator is based on the wiring type. FT NOTE: On steel insulated doors, a 24 ga. Back panel is shipped from the ...
...preset time (only available with B2 wiring and a monitored safety device). • Wiring Types: The functionality of the operator is recommended for descriptions of reliable and safe operation. Steel 18 ga. Steel ROLLING DOOR SECTIONAL DOOR Aluminum Aluminum Grilles Doors --- --- --- 24 ga. Steel Insulated 16 ...Close feature allows the door to Basic Programming Section for rolling sheet doors. Intended for use on a standard lift sectional door. The MHS operator is based on the wiring type. FT NOTE: On steel insulated doors, a 24 ga. Back panel is shipped from the ...
MJ5011E Installation-2008 Manual
Page 4
Supports both monitored and non-monitored safety devices including LiftMaster CPS photo-eyes and industry standard sensing edges. MJ Floor level disconnect for emergency manual chain hoist operation. Bracket Mounting (rolling door) 18.5" (1487.5c0m") A B 6(1.636.4.55"01 "cm) B A A B 141.47.57"5" (37.47 ... Day Max DRIVE TRAIN Maintenance Free Bearings FINISH Powder coated, Corrosion Resistant Steel SAFETY DISCONNECT: MH Floor level chain hoist for emergency manual operation. lbs/ sec. OPERATOR DIMENSIONS WEIGHTS AND DIMENSIONS HANGING WEIGHT:60-70 LBS. (27.22-31.75 kg) 122...
Supports both monitored and non-monitored safety devices including LiftMaster CPS photo-eyes and industry standard sensing edges. MJ Floor level disconnect for emergency manual chain hoist operation. Bracket Mounting (rolling door) 18.5" (1487.5c0m") A B 6(1.636.4.55"01 "cm) B A A B 141.47.57"5" (37.47 ... Day Max DRIVE TRAIN Maintenance Free Bearings FINISH Powder coated, Corrosion Resistant Steel SAFETY DISCONNECT: MH Floor level chain hoist for emergency manual operation. lbs/ sec. OPERATOR DIMENSIONS WEIGHTS AND DIMENSIONS HANGING WEIGHT:60-70 LBS. (27.22-31.75 kg) 122...
MJ5011E Installation-2008 Manual
Page 5
... working smoothly. If your installation check that all components were provided. 3 ^OPEN ^CLOSE O STOP 1 2 ITEM 1 2 3 4 5 6 DESCRIPTION QTY Operator 1 Warning labels 2 3-Button station 1 Hoist hand chain (models MH and MHS only) 1 Door/Operator chain 1 Door sprocket 1 4 6 5 NOT SHOWN Installation Manual 1 Quickstart Guide 1 User's Guide 1 Caution Label 1 Installation Hardware Box 1 Complete with manual hoist hand chain...
... working smoothly. If your installation check that all components were provided. 3 ^OPEN ^CLOSE O STOP 1 2 ITEM 1 2 3 4 5 6 DESCRIPTION QTY Operator 1 Warning labels 2 3-Button station 1 Hoist hand chain (models MH and MHS only) 1 Door/Operator chain 1 Door sprocket 1 4 6 5 NOT SHOWN Installation Manual 1 Quickstart Guide 1 User's Guide 1 Caution Label 1 Installation Hardware Box 1 Complete with manual hoist hand chain...
MJ5011E Installation-2008 Manual
Page 9
... ONLY) Keyhole Bracket 4' above floor A Secure keyhole bracket to mounting surface using appropriate method and hardware. Operator Operator 8 INSTALL MANUAL DISCONNECT SYSTEMS The MHS operator includes both a floor level disconnect chain to disconnect the door from the door operator and a disconnect chain with pad locking provisions) B Wrap hand chain around hand chain wheel and through...
... ONLY) Keyhole Bracket 4' above floor A Secure keyhole bracket to mounting surface using appropriate method and hardware. Operator Operator 8 INSTALL MANUAL DISCONNECT SYSTEMS The MHS operator includes both a floor level disconnect chain to disconnect the door from the door operator and a disconnect chain with pad locking provisions) B Wrap hand chain around hand chain wheel and through...
MJ5011E Installation-2008 Manual
Page 21
... through the keyhole bracket mounted on one side or the other of the continuous loop hoist chain. 3. Or if emergency egress device is used . MODEL MH These operators are equipped with manual hoist to the appropriate instructions below for your door. • If possible, use emergeny disconnect unless doorway is CLOSED. The...
... through the keyhole bracket mounted on one side or the other of the continuous loop hoist chain. 3. Or if emergency egress device is used . MODEL MH These operators are equipped with manual hoist to the appropriate instructions below for your door. • If possible, use emergeny disconnect unless doorway is CLOSED. The...
MJ5011E Installation-2008 Manual
Page 31
...Control: Includes visor clip. 333LM OPEN 3-Button Tri-Colored Remote Control: Includes visor clip. May be used with MJ, MGJ, and MH operators. For use with EXT-ANT for medium duty. ENTRAPMENT PROTECTION DEVICES OPEN CPS-LN4 OPEN Commercial ProtectorCLOSSE ystem: Provides protection on doors up ... enclosure. PRESS TO R ING CLOSE Vehicle Detection System Pneumatic Edge Kit 7 Conductor 20 AWG Wire (500'): Recommended for TO MJ, MH, and MHS.RING 10-9095 ANTENNA EXT-ANT OPEN Medium Duty Angle Mounting Bracket: CLOSE Heavy-gauge steel bracket. OPEN CLOSE Antenna: External kit for...
...Control: Includes visor clip. 333LM OPEN 3-Button Tri-Colored Remote Control: Includes visor clip. May be used with MJ, MGJ, and MH operators. For use with EXT-ANT for medium duty. ENTRAPMENT PROTECTION DEVICES OPEN CPS-LN4 OPEN Commercial ProtectorCLOSSE ystem: Provides protection on doors up ... enclosure. PRESS TO R ING CLOSE Vehicle Detection System Pneumatic Edge Kit 7 Conductor 20 AWG Wire (500'): Recommended for TO MJ, MH, and MHS.RING 10-9095 ANTENNA EXT-ANT OPEN Medium Duty Angle Mounting Bracket: CLOSE Heavy-gauge steel bracket. OPEN CLOSE Antenna: External kit for...
MJ (BLACK LINE) Manual
Page 1
OWNER'S MANUAL MODELS: MJ ✦ MH ✦ HMJ INDUSTRIAL DUTY DOOR OPERATOR FACTORY SET C2 Wiring See page 8 for other wiring configurations 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6
OWNER'S MANUAL MODELS: MJ ✦ MH ✦ HMJ INDUSTRIAL DUTY DOOR OPERATOR FACTORY SET C2 Wiring See page 8 for other wiring configurations 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6
MJ (BLACK LINE) Manual
Page 2
...SIGHT OF DOOR OR ANY OTHER CONTROL (AUTOMATIC OR MANUAL) IS USED. A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OPERATOR INSTALLATIONS. Wall Mounting B - HAND CHAIN WHEEL: .........Left or right handing Models MH and HMJ only. WEIGHTS AND DIMENSIONS HANGING WEIGHT: .........80-110 LBS. 12.69" 6.34" 6.34" 6.13" 3.63... 50Hz CURRENT See motor nameplate ELECTRICAL TRANSFORMER 24Vac CONTROL STATION: ......NEMA 1 3-button station. See pages 13 and 14 for emergency manual door operation. Secondary: #48 chain/sprocket. Model MH: Floor level chain hoist with Model...
...SIGHT OF DOOR OR ANY OTHER CONTROL (AUTOMATIC OR MANUAL) IS USED. A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OPERATOR INSTALLATIONS. Wall Mounting B - HAND CHAIN WHEEL: .........Left or right handing Models MH and HMJ only. WEIGHTS AND DIMENSIONS HANGING WEIGHT: .........80-110 LBS. 12.69" 6.34" 6.34" 6.13" 3.63... 50Hz CURRENT See motor nameplate ELECTRICAL TRANSFORMER 24Vac CONTROL STATION: ......NEMA 1 3-button station. See pages 13 and 14 for emergency manual door operation. Secondary: #48 chain/sprocket. Model MH: Floor level chain hoist with Model...
MJ (BLACK LINE) Manual
Page 3
...and in the door opening, hook the chain off to the door shaft. Permit the operator to be fastened securely and with Bearing (Not Provided) Door Sprocket 5-1/2" (13.97 cm) All MJ, MH, and HMJ series operators have dual output shafts and may not reverse when required. • NEVER try to ...loosen, move the drive sprocket, loosen BOTH set screws securely Hand Chain Handing For MH and HMJ models with manual hoist hand chain systems, the handing of the operator must : a. This surface must be determined at the time of order. If your installation causes the hand chain...
...and in the door opening, hook the chain off to the door shaft. Permit the operator to be fastened securely and with Bearing (Not Provided) Door Sprocket 5-1/2" (13.97 cm) All MJ, MH, and HMJ series operators have dual output shafts and may not reverse when required. • NEVER try to ...loosen, move the drive sprocket, loosen BOTH set screws securely Hand Chain Handing For MH and HMJ models with manual hoist hand chain systems, the handing of the operator must : a. This surface must be determined at the time of order. If your installation causes the hand chain...
MJ (BLACK LINE) Manual
Page 5
...chain to engage the hoist mechanism. MANUAL OPERATION This operator has provisions for manually operating the door in the chain guide. Model MH These operators are equipped with pad locking provisions) 3. An electrical interlock will operate again electrically. Or if emergency egress ... Electrical Interlock with manual hoist to Model MH instructions above for manual operation. 5 Manual Disconnect for your door. 2. Refer to electrically disable the operator controls. 1. 7. WARNING To prevent possible SERIOUS INJURY from the door operator. 1. To disengage, pull the chain...
...chain to engage the hoist mechanism. MANUAL OPERATION This operator has provisions for manually operating the door in the chain guide. Model MH These operators are equipped with pad locking provisions) 3. An electrical interlock will operate again electrically. Or if emergency egress ... Electrical Interlock with manual hoist to Model MH instructions above for manual operation. 5 Manual Disconnect for your door. 2. Refer to electrically disable the operator controls. 1. 7. WARNING To prevent possible SERIOUS INJURY from the door operator. 1. To disengage, pull the chain...
MJ (BLACK LINE) Manual
Page 17
... Support Bracket Yoke Disconnect Lever Disconnect Shaft Tension Spring Sash Chain, 12' Cotter Pin 1/8x1-3/4" ZP Cotter Pin 5/32x1-1/2" Roll Pin 1/8x1" K75-12588 · MH DISCONNECT SERVICE KIT ITEM H1 H2 H3 H4 H5 H6 PART# 10-10707 10-10708 10-10875 10-10988 11-10982 19-8A-12 DESCRIPTION... Assembly Knurled Cup 1/4-20x3/16 SS 10-32x3" SLTD Pan Head ZP Cotter Pin 5/32"x1-1/2" Brake Kits K75-12492 K75-12494 For 115 Volt Operators For 230 Volt...
... Support Bracket Yoke Disconnect Lever Disconnect Shaft Tension Spring Sash Chain, 12' Cotter Pin 1/8x1-3/4" ZP Cotter Pin 5/32x1-1/2" Roll Pin 1/8x1" K75-12588 · MH DISCONNECT SERVICE KIT ITEM H1 H2 H3 H4 H5 H6 PART# 10-10707 10-10708 10-10875 10-10988 11-10982 19-8A-12 DESCRIPTION... Assembly Knurled Cup 1/4-20x3/16 SS 10-32x3" SLTD Pan Head ZP Cotter Pin 5/32"x1-1/2" Brake Kits K75-12492 K75-12494 For 115 Volt Operators For 230 Volt...