Technical Reference
Page 18
Power requirements The following tables list the nominal average power requirements (including fuser power). Warning-Potential Damage: Lexmark recommends that you do not use voltage converters with 110 V printer is not supported on ... printing 100-110 V 110-127 V 220-240 V 8.7 A 7.6 A 4.1 A 8.7 A 7.6 A 4.1 A Note: Automatic duplex is not recommended. Lexmark C54x nominal average power requirements Printing states C540n, C543dn Average power while printing continuously 1-sided (simplex) 2-sided (duplex) 480 W 340 W C544n, C544dn, C544dw, C544dtn 500 W 340 W Average power ...
Power requirements The following tables list the nominal average power requirements (including fuser power). Warning-Potential Damage: Lexmark recommends that you do not use voltage converters with 110 V printer is not supported on ... printing 100-110 V 110-127 V 220-240 V 8.7 A 7.6 A 4.1 A 8.7 A 7.6 A 4.1 A Note: Automatic duplex is not recommended. Lexmark C54x nominal average power requirements Printing states C540n, C543dn Average power while printing continuously 1-sided (simplex) 2-sided (duplex) 480 W 340 W C544n, C544dn, C544dw, C544dtn 500 W 340 W Average power ...
Technical Reference
Page 50
... Return string 80 Scheduled Maintenance 81 Scheduled Maintenance 80 Belt Exhausted 80 Belt Life Warning 80 Fuser/Belt Exhausted 80 Fuser/Belt Life Warning 80 Fuser Exhausted 80 Fuser Life Warning 80 Fuser Maintenance 83 ITU Maintenance Printer model C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP X X X X X X X X X X X X X X X X X X X X PJL messages for attendance conditions = Supported X = Not supported Printer...
... Return string 80 Scheduled Maintenance 81 Scheduled Maintenance 80 Belt Exhausted 80 Belt Life Warning 80 Fuser/Belt Exhausted 80 Fuser/Belt Life Warning 80 Fuser Exhausted 80 Fuser Life Warning 80 Fuser Maintenance 83 ITU Maintenance Printer model C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP X X X X X X X X X X X X X X X X X X X X PJL messages for attendance conditions = Supported X = Not supported Printer...
Technical Reference
Page 58
... - 40049 STMSG message X X STMSG Intervention Required - 40049 PJL ST Message STMSG message Intervention Required - 40050 Replace Fuser X X Replace Fuser Intervention Required - 40050 Replace X X Replace Transfer Kit Transfer Kit Intervention Required - 40087 59 Incompatible X X Incompatible .... Retry? Retry? Appendix B: PJL support 58 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP Intervention Required - 40039 89 Cartridge X X Cartridge Empty Empty Intervention Required -...
... - 40049 STMSG message X X STMSG Intervention Required - 40049 PJL ST Message STMSG message Intervention Required - 40050 Replace Fuser X X Replace Fuser Intervention Required - 40050 Replace X X Replace Transfer Kit Transfer Kit Intervention Required - 40087 59 Incompatible X X Incompatible .... Retry? Retry? Appendix B: PJL support 58 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP Intervention Required - 40039 89 Cartridge X X Cartridge Empty Empty Intervention Required -...
Technical Reference
Page 61
Appendix B: PJL support 61 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP Intervention Required - 40204 84 unsupported X X Unsupported PC Unit [color] pc... Module Near Life Warning module near life warning Intervention Required - 40216 87 Fuser Life X X Fuser Life Warning Warning Intervention Required - 40216 80.yy Fuser X X Fuser Life Warning life warning Intervention Required - 40216 80.yy Fuser X X Fuser Near Life Warning near life warning Intervention Required - 40300 88 Replace X ...
Appendix B: PJL support 61 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP Intervention Required - 40204 84 unsupported X X Unsupported PC Unit [color] pc... Module Near Life Warning module near life warning Intervention Required - 40216 87 Fuser Life X X Fuser Life Warning Warning Intervention Required - 40216 80.yy Fuser X X Fuser Life Warning life warning Intervention Required - 40216 80.yy Fuser X X Fuser Near Life Warning near life warning Intervention Required - 40300 88 Replace X ...
Technical Reference
Page 63
... X X Replace Transfer Module transfer module Intervention Required - 40316 80.yy Replace X X Replace Fuser fuser Intervention Required - 40316 87.yy Replace X X Replace Fuser fuser Intervention Required - 40316 80 Scheduled X X Scheduled Maintenance maintenance [x] Note: [x] indicates 100k kit.... Appendix B: PJL support 63 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/...
... X X Replace Transfer Module transfer module Intervention Required - 40316 80.yy Replace X X Replace Fuser fuser Intervention Required - 40316 87.yy Replace X X Replace Fuser fuser Intervention Required - 40316 80 Scheduled X X Scheduled Maintenance maintenance [x] Note: [x] indicates 100k kit.... Appendix B: PJL support 63 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/...
Technical Reference
Page 65
Appendix B: PJL support 65 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP Intervention Required - 40410 31.yy Defective X X Defective Cartridge cyan cartridge ...40412 31.41 Missing X X Missing or Defective Cartridge or defective yellow cartridge Intervention Required - 40416 80.yy Fuser X X Fuser Missing missing Intervention Required - 40416 87.yy Fuser X X Fuser Missing missing Intervention Required - Insert Duplex Pages in Tray 41202 Reload printed pages in Tray * This message ...
Appendix B: PJL support 65 = Supported X = Not supported Printer model Message Status code Return string C540n, C543dn, C544n/dn/dw/dtn X546dtn MFP Intervention Required - 40410 31.yy Defective X X Defective Cartridge cyan cartridge ...40412 31.41 Missing X X Missing or Defective Cartridge or defective yellow cartridge Intervention Required - 40416 80.yy Fuser X X Fuser Missing missing Intervention Required - 40416 87.yy Fuser X X Fuser Missing missing Intervention Required - Insert Duplex Pages in Tray 41202 Reload printed pages in Tray * This message ...
Service Manual
Page 20
Either OK or Replace appears. 5025-2xx, 4xx Printer specifications Memory ✔-Supported ✘-Not supported Lexmark C540n, C543dn Lexmark C544n, C544dn, C544dw Memory Optional slots Standard DIMM sizesa Optional (DDR2) Maximum printer memoryb One slot 128MB ...ensure highquality printing and good performance throughout the life of the printer, components are subject to wear based on the operator panel. 2. The fuser and ITU replacement should be plugged into an available memory slot. Select Reports from a compatible camera) Wireless standard 802.11 b/g/n ✘...
Either OK or Replace appears. 5025-2xx, 4xx Printer specifications Memory ✔-Supported ✘-Not supported Lexmark C540n, C543dn Lexmark C544n, C544dn, C544dw Memory Optional slots Standard DIMM sizesa Optional (DDR2) Maximum printer memoryb One slot 128MB ...ensure highquality printing and good performance throughout the life of the printer, components are subject to wear based on the operator panel. 2. The fuser and ITU replacement should be plugged into an available memory slot. Select Reports from a compatible camera) Wireless standard 802.11 b/g/n ✘...
Service Manual
Page 21
...Energy, Paper, and Energy+ Paper. • Print quality is maintained. • Power Saver is set to one minute. • Fuser standby is off. • The operator panel back light is off. • Power supply energy consumption is reduced. • Duplex...approved by the driver). There are not supported. 5025-2xx, 4xx Connectivity (network support) ✔-Supported ✘-Not supported Network protocol Lexmark C540n, C543dn, C544dn Lexmark C544dw Standard Ethernet 10/100 Base T ✔ ✔ Standard USB-B (Full speed) device port ✔ ✔ USB-A ...
...Energy, Paper, and Energy+ Paper. • Print quality is maintained. • Power Saver is set to one minute. • Fuser standby is off. • The operator panel back light is off. • Power supply energy consumption is reduced. • Duplex...approved by the driver). There are not supported. 5025-2xx, 4xx Connectivity (network support) ✔-Supported ✘-Not supported Network protocol Lexmark C540n, C543dn, C544dn Lexmark C544dw Standard Ethernet 10/100 Base T ✔ ✔ Standard USB-B (Full speed) device port ✔ ✔ USB-A ...
Service Manual
Page 225
... 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Units/ FRU 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Description Controller board-C544n, C544dn, C544dw Controller board-C540n, C543dn Antenna for wireless card-C544dw only Wireless network card assembly-C544dw only Toner meter cycle card assembly High-voltage power supply Photo sensor (one...), used for: A Tray present B Duplex C Exit/Bin full/narrow media sensor Low-voltage power supply (universal power supply) Fuser exit sensor Power cord, 2.5M (straight)-USA, Canada, Bolivia, Peru, (shown) Power cord, 2.5M (straight)-Argentina Power ...
... 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Units/ FRU 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Description Controller board-C544n, C544dn, C544dw Controller board-C540n, C543dn Antenna for wireless card-C544dw only Wireless network card assembly-C544dw only Toner meter cycle card assembly High-voltage power supply Photo sensor (one...), used for: A Tray present B Duplex C Exit/Bin full/narrow media sensor Low-voltage power supply (universal power supply) Fuser exit sensor Power cord, 2.5M (straight)-USA, Canada, Bolivia, Peru, (shown) Power cord, 2.5M (straight)-Argentina Power ...