UDS-10 - Product Brief
Page 2
... Interface DB25F, RS-232/RS-422/RS-485 serial port with DCE configuration Data Rates Serial speeds 300 bps to screw terminal block connector UDS-100-01 Device Server, 1 DB25 (RS-232, RS-422, RS-485) DCE serial port, RJ45 (10Base-T/100Base-TX) network ports, diagnostic LEDs...VAC power supply UDS-10-02 Same as above with 100-240 VAC power supply with international adapters 15353 Barranca Parkway | Irvine | CA 92618 | USA | Tel: 800.422.7055 | Fax: 949.450.7232 | www.lantronix.com ©2006 Lantronix, Inc. All other trademarks are the property of Lantronix, Inc. Lantronix is a ...
... Interface DB25F, RS-232/RS-422/RS-485 serial port with DCE configuration Data Rates Serial speeds 300 bps to screw terminal block connector UDS-100-01 Device Server, 1 DB25 (RS-232, RS-422, RS-485) DCE serial port, RJ45 (10Base-T/100Base-TX) network ports, diagnostic LEDs...VAC power supply UDS-10-02 Same as above with 100-240 VAC power supply with international adapters 15353 Barranca Parkway | Irvine | CA 92618 | USA | Tel: 800.422.7055 | Fax: 949.450.7232 | www.lantronix.com ©2006 Lantronix, Inc. All other trademarks are the property of Lantronix, Inc. Lantronix is a ...
UDS-10 / UDS100 - User Guide
Page 13
The fourth, fifth, and sixth bytes are fixed and read 00-20-4A, identifying the unit as a Lantronix product. Figure 2-2. Sample Hardware Address 00-20-4A-14-01-18 or 00:20:4A:14:01:18 13 UDS10/UDS100 User Guide Introduction Product Information Label The product information label on the underside of the...
The fourth, fifth, and sixth bytes are fixed and read 00-20-4A, identifying the unit as a Lantronix product. Figure 2-2. Sample Hardware Address 00-20-4A-14-01-18 or 00:20:4A:14:01:18 13 UDS10/UDS100 User Guide Introduction Product Information Label The product information label on the underside of the...
UDS-10 / UDS100 - User Guide
Page 27
... demonstrates how to the unit's Setup Mode. The range is similar to select flow control options: Table 5-5. UDS10/UDS100 User Guide Configuring the UDS Using Telnet or the Serial Port The following table displays available I /F Mode Setting Binary Hex RS-232C, 8-bit, No Parity, 1 stop...for stopping serial input/output. Interface Mode Options I/F Mode Option Bit 7 6 5 4 3 2 1 0 RS-232C 00 RS-422/485 01 RS-485 2-wire 11 7 Bit 10 8 Bit 11 No Parity 00 Even Parity 11 Odd Parity 01 1 Stop bit 0 1 2 Stop bit 1 1 The following table to an extension on a PBX system.
... demonstrates how to the unit's Setup Mode. The range is similar to select flow control options: Table 5-5. UDS10/UDS100 User Guide Configuring the UDS Using Telnet or the Serial Port The following table displays available I /F Mode Setting Binary Hex RS-232C, 8-bit, No Parity, 1 stop...for stopping serial input/output. Interface Mode Options I/F Mode Option Bit 7 6 5 4 3 2 1 0 RS-232C 00 RS-422/485 01 RS-485 2-wire 11 7 Bit 10 8 Bit 11 No Parity 00 Even Parity 11 Odd Parity 01 1 Stop bit 0 1 2 Stop bit 1 1 The following table to an extension on a PBX system.
UDS-10 / UDS100 - User Guide
Page 29
...If the command string includes a partial IP address, the UDS interprets it connects to the remote IP address and remote port...1 Connect to 129.1.2.5, port 1234 Connect to 129.1.28.10, port 12 Autostart (Automatic Connection): If you will be... Manual Connection Address Example Command String C121.2.4.5/1 C5 C28.10/12 Result if remote IP is 129.1.2.3 and remote ...port. Datagram Type: When selecting this option, the Lantronix unit scrolls through the table until it to be ... User Guide Configuring the UDS Using Telnet or the Serial Port Manual Connection The UDS attempts to any others....
...If the command string includes a partial IP address, the UDS interprets it connects to the remote IP address and remote port...1 Connect to 129.1.2.5, port 1234 Connect to 129.1.28.10, port 12 Autostart (Automatic Connection): If you will be... Manual Connection Address Example Command String C121.2.4.5/1 C5 C28.10/12 Result if remote IP is 129.1.2.3 and remote ...port. Datagram Type: When selecting this option, the Lantronix unit scrolls through the table until it to be ... User Guide Configuring the UDS Using Telnet or the Serial Port Manual Connection The UDS attempts to any others....
UDS-10 / UDS100 - User Guide
Page 34
...Options Option Bit 7 6 5 4 3 2 1 0 Idle Time Force transmit: 12ms 00 Force transmit: 52ms 01 Force transmit: 250ms 10 Force transmit: 5sec 11 Trailing Characters None 00 One 01 Two 10 Send Characters 2-Byte Send Character Sequence 1 Send Immediately After Send chars 1 Idle Time: Idle time to Hexadecimal.... count on the network and is used in a routed Wide Area Network (WAN). This wait period is not set , the UDS packages the serial data currently in the transmission after recognizing the transmit condition (sendchar or timeout). Send Characters: If 2-...
...Options Option Bit 7 6 5 4 3 2 1 0 Idle Time Force transmit: 12ms 00 Force transmit: 52ms 01 Force transmit: 250ms 10 Force transmit: 5sec 11 Trailing Characters None 00 One 01 Two 10 Send Characters 2-Byte Send Character Sequence 1 Send Immediately After Send chars 1 Idle Time: Idle time to Hexadecimal.... count on the network and is used in a routed Wide Area Network (WAN). This wait period is not set , the UDS packages the serial data currently in the transmission after recognizing the transmit condition (sendchar or timeout). Send Characters: If 2-...