Service Manual
Page 2
... Conditioner Service Manual TABLE OF CONTENTS Model Number Nomenclature ...3 Symbols Used in this Manual ...4 Safety Precautions...5 Dimensions...11 Indoor Unit...11 Outdoor Unit ...12 Product Specifications ...13 Installation ...15 Installation Parts...15 Installation Tools...15 Select the best location ...16 Piping length and elevation ...17 Fixing Installation Plate(Standart Type 18...
... Conditioner Service Manual TABLE OF CONTENTS Model Number Nomenclature ...3 Symbols Used in this Manual ...4 Safety Precautions...5 Dimensions...11 Indoor Unit...11 Outdoor Unit ...12 Product Specifications ...13 Installation ...15 Installation Parts...15 Installation Tools...15 Select the best location ...16 Piping length and elevation ...17 Fixing Installation Plate(Standart Type 18...
Service Manual
Page 13
...Level (Sound Press,1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No. of innovation some specifications may be changed without notification. Due to our policy of Poles Input Running Current Fan Type No. Used / ... Capacity 5 Model Nominal Heating Capacity 5 Air Circulation H/M/L Setting temperature range(cool/heat) Fan motor Output Model No. Product Specifications Product Specifications Indoor Unit Indoor Unit Type Nominal Cooling Capacity 5 Model Nominal Heating Capacity 5 Air Circulation H/M/L Setting temperature range(cool/heat)...
...Level (Sound Press,1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No. of innovation some specifications may be changed without notification. Due to our policy of Poles Input Running Current Fan Type No. Used / ... Capacity 5 Model Nominal Heating Capacity 5 Air Circulation H/M/L Setting temperature range(cool/heat) Fan motor Output Model No. Product Specifications Product Specifications Indoor Unit Indoor Unit Type Nominal Cooling Capacity 5 Model Nominal Heating Capacity 5 Air Circulation H/M/L Setting temperature range(cool/heat)...
Service Manual
Page 14
...Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Packing Dimension W*H*D inch(mm) Stuffing Quantity 20/40ft A3UC363FA0(LMU360CE) 9,000~36,000 2637~10,550 2267~9071 1320~3680 5.9~16.6 1,208/230,60 3 Rotary GK141K 2 Pole Induction(PSC) 1... Temperature 8.3°C(46.94°F)DB/6.1°C(42.98°F)WB -Interconnecting Piping Length 7.5m -Level Difference of Rows & Column/No. Product Specifications Outdoor Unit - Capacities are Net Capacities. 3. 5 : See the page "Combination Table" 4. Fan motor Model Output W Capacitor µF/Vac...
...Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Packing Dimension W*H*D inch(mm) Stuffing Quantity 20/40ft A3UC363FA0(LMU360CE) 9,000~36,000 2637~10,550 2267~9071 1320~3680 5.9~16.6 1,208/230,60 3 Rotary GK141K 2 Pole Induction(PSC) 1... Temperature 8.3°C(46.94°F)DB/6.1°C(42.98°F)WB -Interconnecting Piping Length 7.5m -Level Difference of Rows & Column/No. Product Specifications Outdoor Unit - Capacities are Net Capacities. 3. 5 : See the page "Combination Table" 4. Fan motor Model Output W Capacitor µF/Vac...
Service Manual
Page 30
... box panel by connecting the wires to the Indoor unit. Connect the cable to the outdoor unit should be complied with the following specifications (ETL recognized and CSA certified). RECOMMAND: The power cord connected to the indoor unit by using tie wrap as shown below. AWG14...cable connected to the electrical diagram behind the front panel of the indoor unit.) The earth wire should be complied with the following specifications (ETL recognized and CSA certified). Connecting the Cable between Indoor Unit and Outdoor Unit Connecting the Cable between power source and the...
... box panel by connecting the wires to the Indoor unit. Connect the cable to the outdoor unit should be complied with the following specifications (ETL recognized and CSA certified). RECOMMAND: The power cord connected to the indoor unit by using tie wrap as shown below. AWG14...cable connected to the electrical diagram behind the front panel of the indoor unit.) The earth wire should be complied with the following specifications (ETL recognized and CSA certified). Connecting the Cable between Indoor Unit and Outdoor Unit Connecting the Cable between power source and the...
Service Manual
Page 67
... and wait until LED on the main power again. Service Manual 67 former. 2) The output voltage of power transformer. 3) IC01D(7812) 4) IC02D(7805) 5) IC01A(KIA7036) Specification 1) AC230V ± 30V : Check the rated voltage 2) 15V ± 1.5V 3) DC12V 4) DC5V 5) The voltage of power trans- Trouble 1 The Product doesn't operate at all...
... and wait until LED on the main power again. Service Manual 67 former. 2) The output voltage of power transformer. 3) IC01D(7812) 4) IC02D(7805) 5) IC01A(KIA7036) Specification 1) AC230V ± 30V : Check the rated voltage 2) 15V ± 1.5V 3) DC12V 4) DC5V 5) The voltage of power trans- Trouble 1 The Product doesn't operate at all...