Installation Guide
Page 1
... all safety messages. INSTALLATION INSTRUCTIONS 600 CFM AND 1200 CFM IN-LINE BLOWERS FOR RANGE HOODS INSTRUCTIONS D'INSTALLATION VENTILATEURS EN LIGNE AVEC DÉBIT DE 600 PI³ ET 1200 PI³ POUR HOTTES D'ÉVACUATION Table of Contents/Table des matières IN-LINE BLOWER SAFETY 1 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Venting Requirements 4 Electrical Requirements 5 INSTALLATION INSTRUCTIONS 6 Prepare Location 6 Make Electrical Connection 7 ASSISTANCE OR SERVICE 9 In the U.S.A 9 In Canada 9 WARRANTY 10 SÉCURIT...
... all safety messages. INSTALLATION INSTRUCTIONS 600 CFM AND 1200 CFM IN-LINE BLOWERS FOR RANGE HOODS INSTRUCTIONS D'INSTALLATION VENTILATEURS EN LIGNE AVEC DÉBIT DE 600 PI³ ET 1200 PI³ POUR HOTTES D'ÉVACUATION Table of Contents/Table des matières IN-LINE BLOWER SAFETY 1 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Venting Requirements 4 Electrical Requirements 5 INSTALLATION INSTRUCTIONS 6 Prepare Location 6 Make Electrical Connection 7 ASSISTANCE OR SERVICE 9 In the U.S.A 9 In Canada 9 WARRANTY 10 SÉCURIT...
Installation Guide
Page 2
... service facility for the size of fire and to duct air outside - You can fight the fire with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high settings. do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. ■ NEVER PICK UP A FLAMING PAN - If the flames do not vent exhaust air into spaces within walls or ceilings...
... service facility for the size of fire and to duct air outside - You can fight the fire with a close fitting lid, cookie sheet, or metal tray, then turn hood ON when cooking at high settings. do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. ■ NEVER PICK UP A FLAMING PAN - If the flames do not vent exhaust air into spaces within walls or ceilings...
Installation Guide
Page 3
... screwdriver Parts needed ■ ½" (1.3 cm) UL listed or CSA approved wiring conduit and connectors ■ 6 - 18 AWG wires, one each of the following colors: black, white, red, blue, gray, and green or green/yellow (ground) NOTE: The length of this in -line blower motor and range hood terminal boxes. ■ 11 - All openings in the ceiling and wall where the in -line blower motor system. INSTALLATION REQUIREMENTS...
... screwdriver Parts needed ■ ½" (1.3 cm) UL listed or CSA approved wiring conduit and connectors ■ 6 - 18 AWG wires, one each of the following colors: black, white, red, blue, gray, and green or green/yellow (ground) NOTE: The length of this in -line blower motor and range hood terminal boxes. ■ 11 - All openings in the ceiling and wall where the in -line blower motor system. INSTALLATION REQUIREMENTS...
Installation Guide
Page 4
... through the roof or wall. Consult your HVAC professional for installation (not included). C. D. The exhaust (outlet) opening around the cap. ■ The size of the vent should be used as part of the vent system. D E E B C Makeup air Local building codes may be as close as possible to where the vent system enters the heated portion of the house. Mount on underside of rafters. Duct horizontal, mount to...
... through the roof or wall. Consult your HVAC professional for installation (not included). C. D. The exhaust (outlet) opening around the cap. ■ The size of the vent should be used as part of the vent system. D E E B C Makeup air Local building codes may be as close as possible to where the vent system enters the heated portion of the house. Mount on underside of rafters. Duct horizontal, mount to...
Installation Guide
Page 5
...-amp, fused electrical circuit is located behind the filter on the model/serial rating plate. The model/serial plate is required. ■ If the house has aluminum wiring, follow the procedure below: 1. Connect a section of system = 13.0 ft (3.9 m) Electrical Requirements Observe all local codes and ordinances. Vent Piece Equivalent Length 45° elbow 2.5 ft (0.8 m) 90° elbow 5.0 ft (1.5 m) The maximum equivalent vent lengths are: 10" (25.4 cm) round vents - 60 ft (18.3 m) Example vent system 90 elbow 6 ft (1.8 m) Wall cap...
...-amp, fused electrical circuit is located behind the filter on the model/serial rating plate. The model/serial plate is required. ■ If the house has aluminum wiring, follow the procedure below: 1. Connect a section of system = 13.0 ft (3.9 m) Electrical Requirements Observe all local codes and ordinances. Vent Piece Equivalent Length 45° elbow 2.5 ft (0.8 m) 90° elbow 5.0 ft (1.5 m) The maximum equivalent vent lengths are: 10" (25.4 cm) round vents - 60 ft (18.3 m) Example vent system 90 elbow 6 ft (1.8 m) Wall cap...
Installation Guide
Page 6
... Weight Hazard Use two or more people, move and install range hood. Prepare for the exhaust vent. ■ When cutting or drilling into the ceiling or wall, do not damage electrical wiring or other injury. 3. Disconnect the motor electrical plug from either the inlet (bottom) side or the outlet (top) side of the blower. Using 2 or more people to the mounting location. Blower mounting screws C. Additional stud framing may be required...
... Weight Hazard Use two or more people, move and install range hood. Prepare for the exhaust vent. ■ When cutting or drilling into the ceiling or wall, do not damage electrical wiring or other injury. 3. Disconnect the motor electrical plug from either the inlet (bottom) side or the outlet (top) side of the blower. Using 2 or more people to the mounting location. Blower mounting screws C. Additional stud framing may be required...
Installation Guide
Page 7
... cable 3. B A A. Electrical Connection Inside In-line Blower System 1. UL listed wire connectors C. Use UL listed wire connectors and connect the red wires (E) together. 6. Complete Preparation 1. IMPORTANT: When cutting or drilling into the terminal boxes on the blower motor assembly. Failure to the terminal boxes in the in -line blower housing and range hood. Use UL listed wire connectors and connect the blue wires (F) together. 7. Remove the terminal box covers and set the covers and screws aside. Replace all joints with clamps. Connect the vent system to the mounting...
... cable 3. B A A. Electrical Connection Inside In-line Blower System 1. UL listed wire connectors C. Use UL listed wire connectors and connect the red wires (E) together. 6. Complete Preparation 1. IMPORTANT: When cutting or drilling into the terminal boxes on the blower motor assembly. Failure to the terminal boxes in the in -line blower housing and range hood. Use UL listed wire connectors and connect the blue wires (F) together. 7. Remove the terminal box covers and set the covers and screws aside. Replace all joints with clamps. Connect the vent system to the mounting...
Installation Guide
Page 8
... 6-wire connector assembly to the wires from the home power supply using UL listed wire connectors (see the range hood installation instructions), locate the wiring cable connector inside the range hood. 2. Connect ground wire to green and yellow ground wire in -line blower motor system to the mating cable connector from the 6-wire connector assembly through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire length to the range hood following the instructions that are supplied with the range hood. 8. With the range hood mounted (see the "Make Electrical Power...
... 6-wire connector assembly to the wires from the home power supply using UL listed wire connectors (see the range hood installation instructions), locate the wiring cable connector inside the range hood. 2. Connect ground wire to green and yellow ground wire in -line blower motor system to the mating cable connector from the 6-wire connector assembly through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire length to the range hood following the instructions that are supplied with the range hood. 8. With the range hood mounted (see the "Make Electrical Power...
Installation Guide
Page 9
... and the complete model and serial number of appliances. ■ Installation information. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.). ■ Referrals to local dealers, repair parts distributors and service companies. Whirlpool Canada LP designated service technicians are made with the same precision used to Whirlpool Corporation with : ■ Features and specifications on our...
... and the complete model and serial number of appliances. ■ Installation information. ■ Use and maintenance procedures. ■ Accessory and repair parts sales. ■ Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.). ■ Referrals to local dealers, repair parts distributors and service companies. Whirlpool Canada LP designated service technicians are made with the same precision used to Whirlpool Corporation with : ■ Features and specifications on our...
Installation Guide
Page 10
... an authorized Whirlpool servicer is not available. 10. Service calls to correct the installation of your major appliance, to instruct you need service, first see the "Troubleshooting" section of the Use & Care Guide. You will pay for in accordance with electrical or plumbing codes, or use or when it . Dealer name Address Phone number Model number Serial number Purchase date 10 Outside the 50 United States and Canada, this limited warranty. Repairs when your...
... an authorized Whirlpool servicer is not available. 10. Service calls to correct the installation of your major appliance, to instruct you need service, first see the "Troubleshooting" section of the Use & Care Guide. You will pay for in accordance with electrical or plumbing codes, or use or when it . Dealer name Address Phone number Model number Serial number Purchase date 10 Outside the 50 United States and Canada, this limited warranty. Repairs when your...
Warranty Information
Page 1
... on the product. This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in a manner that have been removed, altered or cannot be repaired in the home and only in-home service is covered by a Whirlpool designated service company. Service calls to published user or operator instructions and/or installation instructions. 4. Consumable parts are excluded from your...
... on the product. This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in a manner that have been removed, altered or cannot be repaired in the home and only in-home service is covered by a Whirlpool designated service company. Service calls to published user or operator instructions and/or installation instructions. 4. Consumable parts are excluded from your...
Dimension Guide
Page 1
... need, add the equivalent length for Range Hoods PRODUCT MODEL NUMBERS UXI0600DY UXI1200DY Electrical Requirements: A 120 volt, 60 Hz, AC only, 15- All openings in the ceiling and wall where the in-line blower motor system will be installed must conform to seal all governing codes and ordinances. For the most efficient and quiet operation: q Use no more than three 90° elbows. Plastic or metal foil vent...
... need, add the equivalent length for Range Hoods PRODUCT MODEL NUMBERS UXI0600DY UXI1200DY Electrical Requirements: A 120 volt, 60 Hz, AC only, 15- All openings in the ceiling and wall where the in-line blower motor system will be installed must conform to seal all governing codes and ordinances. For the most efficient and quiet operation: q Use no more than three 90° elbows. Plastic or metal foil vent...