User Guide
Page 3
... can be required to http://support.intel.com/support/motherboards/server/SE7520JR2/. See "Additional Information and Software" for Intel products, see http://support.intel.com/support/motherboards/server/SE7520JR2/compat.htm. You will also find BIOS error messages and POST code messages. This manual is available in the Technical Product Specification. Chapter 2 provides instructions on using the Intel® Server Board SE7520JR2. This document provides a brief overview...
... can be required to http://support.intel.com/support/motherboards/server/SE7520JR2/. See "Additional Information and Software" for Intel products, see http://support.intel.com/support/motherboards/server/SE7520JR2/compat.htm. You will also find BIOS error messages and POST code messages. This manual is available in the Technical Product Specification. Chapter 2 provides instructions on using the Intel® Server Board SE7520JR2. This document provides a brief overview...
User Guide
Page 4
... Intel® Server Board SE7520JR2 Technical Product Specification Intel® Server Board SE7520JR2 Quick Start User's Guide in the search field at http://support.intel.com/support/motherboards/server/SE7520JR2 Accessories or other Intel server products Spares and Configuration Guide Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product Tested HardwareOperating Systems List Chassis that have been tested with this product Processors...
... Intel® Server Board SE7520JR2 Technical Product Specification Intel® Server Board SE7520JR2 Quick Start User's Guide in the search field at http://support.intel.com/support/motherboards/server/SE7520JR2 Accessories or other Intel server products Spares and Configuration Guide Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product Tested HardwareOperating Systems List Chassis that have been tested with this product Processors...
User Guide
Page 13
......20 Processor Support 21 DIMM Module Memory Capacity Support 22 Keyboard Commands 35 POST Error Beep Codes 49 Error Beep Codes Provided by Intel® Management Modules 49 Product Certification Markings 52 Intel® Server Board SE7520JR2 User Guide xiii Password Recovery Jumper 37 Figure 13. Table 8. Intel® Server Board SE7520JR2 15 Figure 2. Table 5. CMOS Recovery Jumper 38 Tables Table 1. Server Board Connector...
......20 Processor Support 21 DIMM Module Memory Capacity Support 22 Keyboard Commands 35 POST Error Beep Codes 49 Error Beep Codes Provided by Intel® Management Modules 49 Product Certification Markings 52 Intel® Server Board SE7520JR2 User Guide xiii Password Recovery Jumper 37 Figure 13. Table 8. Intel® Server Board SE7520JR2 15 Figure 2. Table 5. CMOS Recovery Jumper 38 Tables Table 1. Server Board Connector...
User Guide
Page 16
... Serial B port Two RJ45 NIC connectors for up to two Intel® Xeon™ processors with 8MB SDRAM Continued 16 Server Board Features Table 1 summarizes the major features of supporting upto three low-profile PCI-X 66/100MHz add-in cards. Server Board Features Feature Description Processors Memory Chipset Support for 10/100/1000 Mb connections Two USB 2.0 ports U320...
... Serial B port Two RJ45 NIC connectors for up to two Intel® Xeon™ processors with 8MB SDRAM Continued 16 Server Board Features Table 1 summarizes the major features of supporting upto three low-profile PCI-X 66/100MHz add-in cards. Server Board Features Feature Description Processors Memory Chipset Support for 10/100/1000 Mb connections Two USB 2.0 ports U320...
User Guide
Page 17
..., each capable of both the Intel Server Chassis SR1400 and SR2400 Server Management / Diagnostics On-board Platform Instrumentation using either Intel Server Chassis SR1400 or SR2400. When integrated with fan speed control. Support for Intel® Server Management 8.x Intel® Light-Guided Diagnostics on all field replaceable units (FRUs) Intel® Server Board SE7520JR2 User Guide 17 Other server configurations can use the legacy 24...
..., each capable of both the Intel Server Chassis SR1400 and SR2400 Server Management / Diagnostics On-board Platform Instrumentation using either Intel Server Chassis SR1400 or SR2400. When integrated with fan speed control. Support for Intel® Server Management 8.x Intel® Light-Guided Diagnostics on all field replaceable units (FRUs) Intel® Server Board SE7520JR2 User Guide 17 Other server configurations can use the legacy 24...
User Guide
Page 21
Processor Support Processor Family FSB Frequency Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Frequency 2.8 GHz 3.0 GHz 3.2 GHz 3.4 GHz 3.6 GHz Memory The Server Board SE7520JR2 provides six DIMM sockets across two channels, Channel A and Channel B. Channel A consists of DIMM sockets...
Processor Support Processor Family FSB Frequency Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Intel® Xeon™ 800 MHz Frequency 2.8 GHz 3.0 GHz 3.2 GHz 3.4 GHz 3.6 GHz Memory The Server Board SE7520JR2 provides six DIMM sockets across two channels, Channel A and Channel B. Channel A consists of DIMM sockets...
User Guide
Page 25
...the server. 3. Turn off all peripheral devices connected to the processor socket. 2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the Safety Information at the beginning of this manual. Intel® Server Board SE7520JR2 User ... from the edge of this book. 2. DDR DIMMs will not physically fit into a server board designed to support DDR2 DIMMs. DDR2 DIMMs will not physically fit into a server board designed to support DDR DIMMs. Installing DIMMs To install DIMMs, follow these steps: 1. Tools and Supplies Needed...
...the server. 3. Turn off all peripheral devices connected to the processor socket. 2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the Safety Information at the beginning of this manual. Intel® Server Board SE7520JR2 User ... from the edge of this book. 2. DDR DIMMs will not physically fit into a server board designed to support DDR2 DIMMs. DDR2 DIMMs will not physically fit into a server board designed to support DDR DIMMs. Installing DIMMs To install DIMMs, follow these steps: 1. Tools and Supplies Needed...
User Guide
Page 31
... Installations and Upgrades 10. Remove the processor. 11. As the server board is shipped, it is configured to DTR TP00772 Figure 10. Turn off the server. 3. Disconnect the AC power cord from the default position covering pins 1 and 3 to support either a DSR signal or a DCD signal. Changing the Serial Port Configuration Intel® Server Board SE7520JR2 User Guide 31
... Installations and Upgrades 10. Remove the processor. 11. As the server board is shipped, it is configured to DTR TP00772 Figure 10. Turn off the server. 3. Disconnect the AC power cord from the default position covering pins 1 and 3 to support either a DSR signal or a DCD signal. Changing the Serial Port Configuration Intel® Server Board SE7520JR2 User Guide 31
User Guide
Page 40
...137; Is AC power available at the AC source. Are all cables correctly connected and secured? Are the processors fully seated in their sockets on the server board? Are all standoffs in the proper location and not touching any components, causing a potential short? Are all ... to turn the server on (power on add-in boards sharing the same interrupt. Are all peripheral devices installed correctly? If the system has a hard disk drive, is a less frequent cause. Check the tested memory, and chassis lists, as well as the supported hardware and operating ...
...137; Is AC power available at the AC source. Are all cables correctly connected and secured? Are the processors fully seated in their sockets on the server board? Are all standoffs in the proper location and not touching any components, causing a potential short? Are all ... to turn the server on (power on add-in boards sharing the same interrupt. Are all peripheral devices installed correctly? If the system has a hard disk drive, is a less frequent cause. Check the tested memory, and chassis lists, as well as the supported hardware and operating ...
User Guide
Page 49
...provide the following additional beep codes. Reseat or replace the failed processor. 1-5-2-1 No processor is installed or the CPU 1 socket is installed. If the beep codes are not generated after the add-in cards are supported by Intel® Management Modules Beep Code Reason for the beeps and action... beep codes are identical. 1-5-2-4 Front-side bus select configuration error. 1-5-4-2 DC power unexpectedly lost. 1-5-4-3 Chipset control failure. 1-5-4-4 Power control failure. Intel® Server Board SE7520JR2 User Guide 49 Please note that not all add-in card.
...provide the following additional beep codes. Reseat or replace the failed processor. 1-5-2-1 No processor is installed or the CPU 1 socket is installed. If the beep codes are not generated after the add-in cards are supported by Intel® Management Modules Beep Code Reason for the beeps and action... beep codes are identical. 1-5-2-4 Front-side bus select configuration error. 1-5-4-2 DC power unexpectedly lost. 1-5-4-3 Chipset control failure. 1-5-4-4 Power control failure. Intel® Server Board SE7520JR2 User Guide 49 Please note that not all add-in card.