Page 8
... Management Bus (SMBUS) Block Diagram 32 Figure 15. Main Screen...56 Figure 16. Hardware Monitor Screen, Manual Fan Control (S1200BTS 81 viii Revision 1.0 Intel order number G13326-003 Intel® Server Board S1200BTL Layout 6 Figure 4. Intel® Server Board S1200BTL - Advanced Screen...59 Figure 17. Processor Configuration Screen 62 Figure 18. Mass Storage Controller Configuration Screen...
... Management Bus (SMBUS) Block Diagram 32 Figure 15. Main Screen...56 Figure 16. Hardware Monitor Screen, Manual Fan Control (S1200BTS 81 viii Revision 1.0 Intel order number G13326-003 Intel® Server Board S1200BTL Layout 6 Figure 4. Intel® Server Board S1200BTL - Advanced Screen...59 Figure 17. Processor Configuration Screen 62 Figure 18. Mass Storage Controller Configuration Screen...
Product Specification
Page 62
...S1200BT TPS 6.4 BIOS Boot Pop-up Menu The BIOS Boot Specification (BBS) provides a Boot Pop-up menu that can be booted, and allows a manual selection of the desired boot device. The BBS Pop-up menu displays all selection and data entry fields in Setup (except System Time and Date... in devices, the boot manager, and error manager. the user will be changed unless the Administrative Password has been entered. 50 Revision 1.0 Intel order number G13326-003 The pop-up menu is capable of displaying data and input in Setup fields in Setup, the Administrator password will not...
...S1200BT TPS 6.4 BIOS Boot Pop-up Menu The BIOS Boot Specification (BBS) provides a Boot Pop-up menu that can be booted, and allows a manual selection of the desired boot device. The BBS Pop-up menu displays all selection and data entry fields in Setup (except System Time and Date... in devices, the boot manager, and error manager. the user will be changed unless the Administrative Password has been entered. 50 Revision 1.0 Intel order number G13326-003 The pop-up menu is capable of displaying data and input in Setup fields in Setup, the Administrator password will not...
Product Specification
Page 93
Revision 1.0 81 Intel order number G13326-003 Hardware Monitor Screen, Manual Fan Control (S1200BTS) 6.5.2.17 Realtime Temperature and Voltage Status The Realtime Temperature and Voltage Status screen allows the user to view displays of current ...60%/80%/100%] [2 Degree Celsius/3 Degree Celsius/4 Degree Celsius [40%/60%/80%/100%] Figure 32. Intel®Server Board S1200BT TPS Hardware Monitor Server Management ► Real-time Temperature and Voltage Status Fan Controller Auto / Manual CPU Fan Altitude System Fan Altitude 300m/900m/1500m/3000m 300m/900m/1500m/3000m BIOS User...
Revision 1.0 81 Intel order number G13326-003 Hardware Monitor Screen, Manual Fan Control (S1200BTS) 6.5.2.17 Realtime Temperature and Voltage Status The Realtime Temperature and Voltage Status screen allows the user to view displays of current ...60%/80%/100%] [2 Degree Celsius/3 Degree Celsius/4 Degree Celsius [40%/60%/80%/100%] Figure 32. Intel®Server Board S1200BT TPS Hardware Monitor Server Management ► Real-time Temperature and Voltage Status Fan Controller Auto / Manual CPU Fan Altitude System Fan Altitude 300m/900m/1500m/3000m 300m/900m/1500m/3000m BIOS User...
Product Specification
Page 133
The following abbreviations are used in the comment column to describe a sensor: A: Auto-rearm M: Manual rearm I: Rearm by the sensor. Revision 1.0 121 Intel order number G13326-003 It also controls the behavior of the sensor. These sensors may be accessed and/or generate events when ... the count of hysteresis for a sensor to all thresholds of the front panel status LED. Standby Some sensors operate on standby power. Intel®Server Board S1200BT TPS Appendix B: Integrated BMC Sensor Tables T: Threshold value Rearm Sensors The rearm is a request for the event ...
The following abbreviations are used in the comment column to describe a sensor: A: Auto-rearm M: Manual rearm I: Rearm by the sensor. Revision 1.0 121 Intel order number G13326-003 It also controls the behavior of the sensor. These sensors may be accessed and/or generate events when ... the count of hysteresis for a sensor to all thresholds of the front panel status LED. Standby Some sensors operate on standby power. Intel®Server Board S1200BT TPS Appendix B: Integrated BMC Sensor Tables T: Threshold value Rearm Sensors The rearm is a request for the event ...