NS2 Configuration Guide
Honeywell Access Systems
Enclosure Specifications
Mounting
One NS2 panel in a single 19-inch rack mountable enclosure
Dimensions Board Enclosure
9-inch Length x... (Fiber to RS-232) [Discontinued] and F290D (Fiber to RS-485) [Discontinued] are not supported with the NS2 panel(s).
4
7-101004-01 Up to eight NS2 panels in a standard 19-inch, high density enclosure.
Configuration Guide - Page 7
... Configuration Guide
NStar Server
COM 1 COM 2
CBL50 (RS-232) 50 ft.
EG
RS-232 (DB9)
8
CBL50 (RS-232) Request To Send (RTS)
RJ-45 2
5
Signal Ground (GND)
3
2
Receive Data (RXD)
4
3
Transmit Data (TXD)
5
7
Clear To Send (CTS)
7
9-Pin COM 1 or COM 2 to earth ground (EG) each COM port. Honeywell Access Systems
Configuration Diagrams...
Configuration Guide - Page 8
NS2 Configuration Guide
RS-485 Connection
Thirty-one side of cable.
Max.)
RS-485 (4,000 Ft.)
N-485-PCI-2
Refer to earth ground... 2 twisted pairs with shield, 120 ohm, 23 pf (NCI part no. EG
It is recommended to 485-PCI / NS2 Panel Connection
Detail diagram. Honeywell Access Systems
NStar Server
COM Port
RS-232 (50 Ft. NCP2441-TN)
DIP Switch Settings
S1: ON S2: ON S3: ON S4: ON S5: ...
Configuration Guide - Page 9
Max.
Honeywell Access Systems
NSLAN1 Connection
One NSLAN1 for
programing instructions. Max. NS2 Panel
NSLAN1 installed
100BaseT (CAT 5) 328 Ft.
NSLAN1 must be programmed... Switch Settings S1-S5: Panel Address S6: OFF (RS-485 Disable) S7: ON (57,600 Baud Rate) S8-S10: OFF
NS2 Panel
NSLAN1 installed
EG
100BaseT (CAT 5) 328 Ft. Max. EG
7-101004-01
9
NS2 Configuration Guide
NIC
...
Configuration Guide - Page 10
...Baud Rate)
Refer to 485-PCI / NS2 Panel Connection Detail diagram. DIP Switch Settings
S1-S5: Panel Address S6: ON (RS-485 Enable) S7: N/A (Baud Rate) S8-S9...part no. RJ-45 RS-232 (50 Ft.)
N-485-PCI-2L
Refer to LANSRL100 documentation for each NS2 enclosure individually.
10
7-101004-01
NS2 Configuration Guide
LANSRL100 Connection
Thirty-one side of cable. Honeywell Access Systems...
Configuration Guide - Page 11
Honeywell Access Systems
LANSRLU1 Connection
Thirty-one side of cable. NStar Server
HUB
100BaseT (CAT 5) 328 Ft. RJ-45 RS-232 (50 Ft.)
N-485-PCI-2L
Refer to LANSRLU1 documentation for each NS2 enclosure individually.
11
Max.
NS2 Configuration Guide
NIC
100BaseT (CAT 5) 328 Ft.
RS-485 Cable
RS-485
NS2 Panel
NS2 Panel...
Configuration Guide - Page 12
...232 (50 Ft.)
M-9600-LA
RS-485 (4,000 Ft.)
Honeywell Access Systems
Lease Line Phone Line
DIP Switch Settings
S1: ON S2: ON S3: ON S4: ON S5...Panel Connection
Detail diagram.
NCP2441-TN)
12
7-101004-01
NS2 Configuration Guide
Lease Line Modem Connection
Thirty-one side of cable.
Straight Thru ...part no. EG
Only Earth Ground (EG)
EG
one NS2 panels for each NS2...
Configuration Guide - Page 13
... part no.
Male 9 Pin
Male 25 Pin
Refer to earth ground (EG) each drop line. Honeywell Access Systems
RS-485 Short Haul Modem Connection
Thirty-one side of cable. NCP2441-TN)
NS2 Configuration Guide
...7 (GND)
7 (GND)
7-101004-01
13 NStar Server
RS-232, 50 Ft. SHM-B-ASYNC Short Haul Modem
DIP Switch Settings
S1: ON S2: ON S3: ON S4: ON S5: ON S6: OFF (Ack/Nak on) S7: ON S8: OFF...
Configuration Guide - Page 14
NS2 Configuration Guide
RS-232 Short Haul Modem Connection
One NS2 panel for each NS2 enclosure
individually.
14
SHM... NStar Server
RS-232, 50 Ft. SHM-B-ASYNC Short Haul Modem
Honeywell Access Systems
RS232 Cable
PC (DB-9)
2 TX 3 RX 5 Comm
MODEM
DTE (Straight)
DCE (Null)
2 (TX) 3 (RX) or 7 (GND)
2 (RX) 3 (TX) 7 (GND)
DIP Switch Settings
S1-S5: Panel Address S6: OFF (RS-485 Disable) S7...
Configuration Guide - Page 15
...Guide...m) max, 24 AWG, 2 twisted pairs with shield, 120 ohm, 23 pf (NCI part no. EG
It is recommended to 485-PCI / NS2 Panel Connection
Detail diagram.
N-485...RS-485 (4,000 Ft.)
Analog Phone Line
Dedicated analog phone line recommended
DIP Switch Settings
S1: ON S2: ON S3: ON S4: ON S5: ON S6: OFF ...Honeywell Access Systems
M-9600 Dial-up Modem, RS-485 Connection
Thirty-one side of cable.
Configuration Guide - Page 16
...NS2 Panel Connection
Detail diagram. Honeywell Access Systems
NStar Server
Refer to earth ground... 2 twisted pairs with shield, 120 ohm, 23 pf (NCI part no.
N-485-HUB-2
COM Port
Female 9 Pin (RX) 2 (TX) 3
(Comm) 5
Straight Thru Cable
M-56K FAX/MODEM
Local DIP Switch Settings (1, 3, 5, 8 ON) (2, 4, 6, 7 OFF)
Male... Guide
M-56K Dial-up Modem, RS-485 Connection
Thirty-one side of cable.
Configuration Guide - Page 17
... RS-485 Comm. NCP2441-TN)
7-101004-01
17 NS2 Configuration Guide
COM Port
Refer to earth ground
RS-485 Drain not connected here...(RS485 +) TB9-2 (RS485 -)
Fiber Wire 10,000 Ft. EG
DIP Switch Settings
S1-S5: Panel Address S6: ON (RS-485 Enable) S7: N/A (Baud... ohm, 23 pf (NCI part no. FC485 RS-485 Fiber Converter
RXD PWR TXD RS-485 Comm. Honeywell Access Systems
Fiber Converter to RS-485 ...
Configuration Guide - Page 18
...(Baud Rate) S8-S9: OFF (Bias) S10: OFF (485 EOL)
485 -
NS2 Configuration Guide
485-PCI/NS2 Panel Connection Detail
DIP Switch Settings S1: ON S2: ON S3: ON S4: ON S5: ON S6: OFF (Ack/Nak on...ft. (1,200 m) max, 24 AWG, 2 twisted pairs with shield, 120 ohm, 23 pf (NCI part no. Honeywell Access Systems
485 Interface Connection Types
RS-485
N-485-PCI-2 N-485-HUB-2 N-485-PCI-2L
NS2 Panel
COM ...
Configuration Guide - Page 19
... details. Starter kit. Contents Software, panel, 2 readers, accessories. How does the NStar software communicate to save on installation space? Neither the NS2 panel nor the NStar software supports the AEP-3 or AEP-5 board. Honeywell Access Systems recommends the PB-VC-15 or higher capture card. Future plans are the minimum PC requirements to release...
Configuration Guide - Page 20
... is information in the NS2 panel(s), after default are set for 10 seconds. 3.
All rights reserved.
20
Specifications subject to download current data.
The NS2 panel uses FLASH memory. See Honeywell Access Systems website (www.honeywellaccess.com) for the NS2 panel after a full initialization of system upgrades or new features. Default LED conditions for further details...
Honeywell NSEK Reviews
Do you have an experience with the Honeywell NSEK that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Honeywell yet.
Earn 750 points for your review!