Specifications
Page 3
...disk assembly ...7 3.3 Actuator...7 4.0 Drive characteristics ...8 4.1 Default logical drive parameters 8 4.2 PData sheet ...9 4.3 World Wide Name Assignment 9 4.4 Drive organization ...9 4.5 Performance characteristics 10 5.0 Defect flagging strategy ...14 5.1 Electrical interface...15 5.2 Signal timings ...22 5.3 Jumper settings(PATA model 35 5.4 Environment ...SMART Function ...68 8.6 Security Mode Feature Set ...70 HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) ii Table of contents 1.0 General...2 1.1 Introduction...2 1.2 Glossary...2 1.3 Caution ...2 1.4 References ...
...disk assembly ...7 3.3 Actuator...7 4.0 Drive characteristics ...8 4.1 Default logical drive parameters 8 4.2 PData sheet ...9 4.3 World Wide Name Assignment 9 4.4 Drive organization ...9 4.5 Performance characteristics 10 5.0 Defect flagging strategy ...14 5.1 Electrical interface...15 5.2 Signal timings ...22 5.3 Jumper settings(PATA model 35 5.4 Environment ...SMART Function ...68 8.6 Security Mode Feature Set ...70 HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) ii Table of contents 1.0 General...2 1.1 Introduction...2 1.2 Glossary...2 1.3 Caution ...2 1.4 References ...
Specifications
Page 10
... chart (Host Terminating Write 33 Figure 17 Jumper pin location ...35 Figure 18 Jumper pin identification...35 Figure 19 Jumper positions for normal use 37 Figure 20 Jumper positions for 15 logical head default 38 Figure 21 Jumper positions for capacity clip to 32GB 39 Figure 22 Jumper settings for Disabling Auto Spin 40 Figure 23... 29 Usual Operation ...72 Figure 30 Password Lost...73 Figure 31 Seek overlap ...78 Figure 32 Device address map before and after Set Feature 82 HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) ix
... chart (Host Terminating Write 33 Figure 17 Jumper pin location ...35 Figure 18 Jumper pin identification...35 Figure 19 Jumper positions for normal use 37 Figure 20 Jumper positions for 15 logical head default 38 Figure 21 Jumper positions for capacity clip to 32GB 39 Figure 22 Jumper settings for Disabling Auto Spin 40 Figure 23... 29 Usual Operation ...72 Figure 30 Password Lost...73 Figure 31 Seek overlap ...78 Figure 32 Device address map before and after Set Feature 82 HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) ix
Specifications
Page 44
RSV GND I G H DS Figure 49. Jumper pin assignment GND E F CS/SP GND C D GND RSV A B RS V HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 36 Selection, The Device 0 setting automatically recognizes device 1 if it is for a slave device that does not comply with the ATA specification. The ...
RSV GND I G H DS Figure 49. Jumper pin assignment GND E F CS/SP GND C D GND RSV A B RS V HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 36 Selection, The Device 0 setting automatically recognizes device 1 if it is for a slave device that does not comply with the ATA specification. The ...
Specifications
Page 45
... Device or Cable Selection mode. When CSEL is open or at a low level, the drive address is 0 (Device 0). HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 37 5.3.4 Jumper positions 5.3.4.1 16 logical head default (normal use Notes: 1. 2. 3. In CSEL mode, installing or removing the jumper blocks at E-F. The shipping default position is 1 (Device 1). IGECA HFDB DEVICE 0 (Master) IGECA...
... Device or Cable Selection mode. When CSEL is open or at a low level, the drive address is 0 (Device 0). HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 37 5.3.4 Jumper positions 5.3.4.1 16 logical head default (normal use Notes: 1. 2. 3. In CSEL mode, installing or removing the jumper blocks at E-F. The shipping default position is 1 (Device 1). IGECA HFDB DEVICE 0 (Master) IGECA...
Specifications
Page 46
... HFDB IGECA HFDB DEVICE 0 (Master) DEVICE 1 (Slave) CABLE SEL DEVICE 1 (Slave) Present Figure 20 Jumper positions for 15 logical head default Notes: 1. 2. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 38 5.3.4.2 15 logical head default The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device 1 (Slave) Present setting 15 logical...
... HFDB IGECA HFDB DEVICE 0 (Master) DEVICE 1 (Slave) CABLE SEL DEVICE 1 (Slave) Present Figure 20 Jumper positions for 15 logical head default Notes: 1. 2. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 38 5.3.4.2 15 logical head default The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device 1 (Slave) Present setting 15 logical...
Specifications
Page 47
HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 39 IGECA HFDB IGECA HFDB IGECA HFDB IGECA HFDB DEVICE 0 (Master) DEVICE 1 (Slave) CABLE SEL DEVICE 1 (Slave) Present Figure 21 Jumper positions for capacity clip to 32GB Notes: The jumper setting acts as a 32GB clip which clips the LBA to 32GB for the purpose of 16383.../16/63. The CHS is unchanged from the factory default of compatibility. 5.3.4.3 Capacity clip to 32GB The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device 1 (Slave) Present while setting the...
HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 39 IGECA HFDB IGECA HFDB IGECA HFDB IGECA HFDB DEVICE 0 (Master) DEVICE 1 (Slave) CABLE SEL DEVICE 1 (Slave) Present Figure 21 Jumper positions for capacity clip to 32GB Notes: The jumper setting acts as a 32GB clip which clips the LBA to 32GB for the purpose of 16383.../16/63. The CHS is unchanged from the factory default of compatibility. 5.3.4.3 Capacity clip to 32GB The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device 1 (Slave) Present while setting the...
Specifications
Page 48
... 1 (Slave) IGECA HFDB CABLE SEL I GECA HFDB DEVICE 1 (Slave) Present Figure 22 Jumper settings for limiting power supply current when multiple drives are used. These jumper settings are used for Disabling Auto Spin Notes: 1. 2. 3. To enable the CSEL mode (...jumper block must be installed at a high level, the drive address is SET FEATURES (subcommand 07h). 5.3.4.4 Power Up In Standby The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device 1 (Slave) Present to 10.37 Set Features. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive...
... 1 (Slave) IGECA HFDB CABLE SEL I GECA HFDB DEVICE 1 (Slave) Present Figure 22 Jumper settings for limiting power supply current when multiple drives are used. These jumper settings are used for Disabling Auto Spin Notes: 1. 2. 3. To enable the CSEL mode (...jumper block must be installed at a high level, the drive address is SET FEATURES (subcommand 07h). 5.3.4.4 Power Up In Standby The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device 1 (Slave) Present to 10.37 Set Features. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive...
Specifications
Page 62
...labels. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 54 Operating mode. or Hitachi Global Storage Technologies approved equivalent • A label containing the drive model number..., the manufacturing date code, the formatted capacity, the place of manufacture, UL/CSA/TUV/CE/C-Tick mark logos • A bar code label containing the drive serial number • A label containing the jumper...
...labels. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 54 Operating mode. or Hitachi Global Storage Technologies approved equivalent • A label containing the drive model number..., the manufacturing date code, the formatted capacity, the place of manufacture, UL/CSA/TUV/CE/C-Tick mark logos • A bar code label containing the drive serial number • A label containing the jumper...
Specifications
Page 88
...the host to sequence the spin-up of jumper. Device power consumption may increase with increasing advanced power management levels. The IDENTIFY DEVICE response word 83, bit 3 indicates that the response is enabled if set . HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 80 This feature set ..., then only words 0 and 2 are set, the device will be enabled/disabled via the SET FEATURES command. When enabled by a jumper, the feature set (APM) This feature allows the host to enable Advanced Power Management 2. If power-up into Standby is enabled, when...
...the host to sequence the spin-up of jumper. Device power consumption may increase with increasing advanced power management levels. The IDENTIFY DEVICE response word 83, bit 3 indicates that the response is enabled if set . HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1.1) 80 This feature set ..., then only words 0 and 2 are set, the device will be enabled/disabled via the SET FEATURES command. When enabled by a jumper, the feature set (APM) This feature allows the host to enable Advanced Power Management 2. If power-up into Standby is enabled, when...