Specifications
Page 6
...53 7.1 Jumper settings 53 7.1.1 Jumper pin location 53 7.1.2 Jumper pin identification 53 7.1.3 Jumper pin assignment 54 7.1.4 Jumper positions 54 ...7.2 Environment 58 7.2.1 Temperature and humidity 58 7.2.2 Corrosion test 59 7.3 DC power requirements 59 7.3.1 Input voltage 59 7.3.2 Power supply current (typical 60 7.3.3 Power supply generated ripple at drive... hole locations 63 7.5.3 Connector locations 63 7.5.4 Drive mounting 64 7.5.5 Heads unload and actuator lock...
...53 7.1 Jumper settings 53 7.1.1 Jumper pin location 53 7.1.2 Jumper pin identification 53 7.1.3 Jumper pin assignment 54 7.1.4 Jumper positions 54 ...7.2 Environment 58 7.2.1 Temperature and humidity 58 7.2.2 Corrosion test 59 7.3 DC power requirements 59 7.3.1 Input voltage 59 7.3.2 Power supply current (typical 60 7.3.3 Power supply generated ripple at drive... hole locations 63 7.5.3 Connector locations 63 7.5.4 Drive mounting 64 7.5.5 Heads unload and actuator lock...
Specifications
Page 58
...present. RSV GND GND GND RSV I GECA HFDB DS CS/SP GND RSV 7.1.4 Jumper positions 7.1.4.1 16 logical head default (normal use ) • 15 logical head default • 32 GB clip • Power up in standby Within each of these four jumper settings the pin assignment selects Device 0, Device 1, Cable Selection, or Device 1 ...and "Device 1" designates a Slave. IGECA H F D B IGECA HFDB IGECA HFDB IGECA HFDB IGECA H F D B DEVICE 0 (Master) DEVICE 1 (Slave) CABLE SEL DEVICE 1 (Slave) Present Shipping Default Condition (DEVICE 0) Deskstar 7K80 Hard Disk Drive Specification 54
...present. RSV GND GND GND RSV I GECA HFDB DS CS/SP GND RSV 7.1.4 Jumper positions 7.1.4.1 16 logical head default (normal use ) • 15 logical head default • 32 GB clip • Power up in standby Within each of these four jumper settings the pin assignment selects Device 0, Device 1, Cable Selection, or Device 1 ...and "Device 1" designates a Slave. IGECA H F D B IGECA HFDB IGECA HFDB IGECA HFDB IGECA H F D B DEVICE 0 (Master) DEVICE 1 (Slave) CABLE SEL DEVICE 1 (Slave) Present Shipping Default Condition (DEVICE 0) Deskstar 7K80 Hard Disk Drive Specification 54
Specifications
Page 59
... at A-B or C-D position does not affect any selection of default 16 logical head models. Deskstar 7K80 Hard Disk Drive Specification 55 The shipping default position is 1 (Device 1). 2. In CSEL mode, installing or removing the jumper blocks at A-B or C-D position does not affect any selection of Device or Cable Selection mode. Notes: 1. To enable the...
... at A-B or C-D position does not affect any selection of default 16 logical head models. Deskstar 7K80 Hard Disk Drive Specification 55 The shipping default position is 1 (Device 1). 2. In CSEL mode, installing or removing the jumper blocks at A-B or C-D position does not affect any selection of Device or Cable Selection mode. Notes: 1. To enable the...
Specifications
Page 60
... clip to 32GB The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device1 (Slave) Present while setting the drive capacity down to 32 GB for Disabling Auto Spin I GECA HFDB DEVICE...SEL DEVICE 1 (Slave) Present Note: The jumper setting acts as a 32GB clip which clips the LBA to 66055248. Table 40: Jumper positions for capacity clip to 32GB I G E C A H F D B I G E C A H F D B I G E C A H F D B I GECA HFDB DEVICE 1 (Slave) Present Deskstar 7K80 Hard Disk Drive Specification 56 The CHS is unchanged from the ...
... clip to 32GB The figure below shows the jumper positions used to select Device 0, Device 1, Cable Selection, or Device1 (Slave) Present while setting the drive capacity down to 32 GB for Disabling Auto Spin I GECA HFDB DEVICE...SEL DEVICE 1 (Slave) Present Note: The jumper setting acts as a 32GB clip which clips the LBA to 66055248. Table 40: Jumper positions for capacity clip to 32GB I G E C A H F D B I G E C A H F D B I G E C A H F D B I GECA HFDB DEVICE 1 (Slave) Present Deskstar 7K80 Hard Disk Drive Specification 56 The CHS is unchanged from the ...
Specifications
Page 61
Command to 12.28 Set Features. 3. These jumper settings are used for limiting power supply current when multiple drives are used. 2. Deskstar 7K80 Hard Disk Drive Specification 57 To enable the CSEL mode (Cable Selection mode) the jumper block must be installed at a high level, the drive address is 1 (Device 1). Refer to spin up is open or at...
Command to 12.28 Set Features. 3. These jumper settings are used for limiting power supply current when multiple drives are used. 2. Deskstar 7K80 Hard Disk Drive Specification 57 To enable the CSEL mode (Cable Selection mode) the jumper block must be installed at a high level, the drive address is 1 (Device 1). Refer to spin up is open or at...
Specifications
Page 72
... drive ...drive: • A label containing the Hitachi logo, the Hitachi Global Storage Technologies part number and the statement " Made by Hitachi... Global Storage Technologies Inc." Table 53: Sound power levels Idle Operating Mode Performance seek mode Quiet seek mode Typical/Max 2.6 / 3.0 3.4 / 3.7 2.8 / 3.2 Mode definitions • Idle mode: The drive... following table. or Hitachi Global Storage Technologies approved equivalent. • A label containing the drive model number, the ...containing the drive serial number • A label containing jumper pin description...
... drive ...drive: • A label containing the Hitachi logo, the Hitachi Global Storage Technologies part number and the statement " Made by Hitachi... Global Storage Technologies Inc." Table 53: Sound power levels Idle Operating Mode Performance seek mode Quiet seek mode Typical/Max 2.6 / 3.0 3.4 / 3.7 2.8 / 3.2 Mode definitions • Idle mode: The drive... following table. or Hitachi Global Storage Technologies approved equivalent. • A label containing the drive model number, the ...containing the drive serial number • A label containing jumper pin description...
Specifications
Page 105
When enabled by a jumper, the feature set shall not be disabled via the SET FEATURES command or the use of devices. The enabling of powering up into ...Standby until the SET FEATURES subcommand is enabled or disabled • the device needs the Set Features command to spin-up into active state Deskstar 7K80 Hard Disk Drive Specification 101 A device needs a SET FEATURES subcommand to spin-up to active state when the device has powered up into Standby. If ...the Standby power management state to minimize inrush current at power-up and to allow the host to sequence the spin-up of a jumper.
When enabled by a jumper, the feature set shall not be disabled via the SET FEATURES command or the use of devices. The enabling of powering up into ...Standby until the SET FEATURES subcommand is enabled or disabled • the device needs the Set Features command to spin-up into active state Deskstar 7K80 Hard Disk Drive Specification 101 A device needs a SET FEATURES subcommand to spin-up to active state when the device has powered up into Standby. If ...the Standby power management state to minimize inrush current at power-up and to allow the host to sequence the spin-up of a jumper.
Specifications
Page 145
...1=assert 0=not assert 10-9 How to determine the device number: 00=Reserved. 01=Jumper. 10=the CSEL signal. 11=some other method. 0 Shall be set to one if Dev 0. Deskstar 7K80 Hard Disk Drive Specification 141 detection. 1=detect 0=not detect 3 Device diag. 1=pass 0=fail 2-1 ...How to determine the device number 00=Reserved. 01=Jumper. 10=CSEL signal. 11=Some other method. 8 Shall be set to...
...1=assert 0=not assert 10-9 How to determine the device number: 00=Reserved. 01=Jumper. 10=the CSEL signal. 11=some other method. 0 Shall be set to one if Dev 0. Deskstar 7K80 Hard Disk Drive Specification 141 detection. 1=detect 0=not detect 3 Device diag. 1=pass 0=fail 2-1 ...How to determine the device number 00=Reserved. 01=Jumper. 10=CSEL signal. 11=Some other method. 8 Shall be set to...