HP Vectra XM 5/xxx Series 3 - User Guide
Page 9
... Your Password 73 If You Can't Start the SETUP Program 74 If Your Application Software Does Not Work 74 If Power Management Does Not Work 75 If the Date and Time Are Incorrect 75 Using the HP SETUP Program 76 Starting the SETUP Program 76 English ix
... Your Password 73 If You Can't Start the SETUP Program 74 If Your Application Software Does Not Work 74 If Power Management Does Not Work 75 If the Date and Time Are Incorrect 75 Using the HP SETUP Program 76 Starting the SETUP Program 76 English ix
HP Vectra XM 5/xxx Series 3 - User Guide
Page 27
... the Screen Blanking line is highlighted. 8 Press or to save this setting and exit SETUP. Enabled. 11 Use the key to select a value between 1 and 75 minutes. again. If you wish to select Screen Blanking . . . Setting Screen Blanking 9 Press the key until the Keyboard Lock Timer line is highlighted. 10 Press...
... the Screen Blanking line is highlighted. 8 Press or to save this setting and exit SETUP. Enabled. 11 Use the key to select a value between 1 and 75 minutes. again. If you wish to select Screen Blanking . . . Setting Screen Blanking 9 Press the key until the Keyboard Lock Timer line is highlighted. 10 Press...
HP Vectra XM 5/xxx Series 3 - User Guide
Page 71
...if the battery is incorrectly installed. WARNING There is installed by trained service personnel. In order to recharge, disassemble, or burn the old battery. HP recommends that the battery is a danger of in the household waste. 4 Troubleshooting Your PC and Using the SETUP Program Solving Problems If Your PC...forgotten your passwords, turn to page 74. Ì If you can't start the SETUP program, turn to page 75. Ì If your application software does not work, turn to page 75. Ì If power management does not work, turn to page 76. Please return used batteries to the shop ...
...if the battery is incorrectly installed. WARNING There is installed by trained service personnel. In order to recharge, disassemble, or burn the old battery. HP recommends that the battery is a danger of in the household waste. 4 Troubleshooting Your PC and Using the SETUP Program Solving Problems If Your PC...forgotten your passwords, turn to page 74. Ì If you can't start the SETUP program, turn to page 75. Ì If your application software does not work, turn to page 75. Ì If power management does not work, turn to page 76. Please return used batteries to the shop ...
HP Vectra XM 5/xxx Series 3 - User Guide
Page 75
... the configuration is stuck down on the keyboard, and that no key is repeatedly lost. 4 If all shadowing in SETUP. 2 If this chapter on page 75). 3 If the problem persists, the system board may need to be replaced. Make a written note of the configuration. 3 If the hardware was changed, run SETUP...
... the configuration is stuck down on the keyboard, and that no key is repeatedly lost. 4 If all shadowing in SETUP. 2 If this chapter on page 75). 3 If the problem persists, the system board may need to be replaced. Make a written note of the configuration. 3 If the hardware was changed, run SETUP...
HP Vectra XM 5/xxx Series 3 - User Guide
Page 87
....EXE ADV:MAX DOS is present in the CONFIG.SYS file. If the Date and Time Are Incorrect The date and time can use the HP User Tools program. To change the date and time. 4 Troubleshooting Your PC and Using the SETUP Program If Your PC Has a Software Problem If Power... Control Panel. 2 Check that the Sleep icon appears in Use a text editor to MS-DOS with APM. If it is discharged. English 75 If you do not have the HP User Tools program installed, you can be incorrect for the following reasons: • the time has changed for more information about the...
....EXE ADV:MAX DOS is present in the CONFIG.SYS file. If the Date and Time Are Incorrect The date and time can use the HP User Tools program. To change the date and time. 4 Troubleshooting Your PC and Using the SETUP Program If Your PC Has a Software Problem If Power... Control Panel. 2 Check that the Sleep icon appears in Use a text editor to MS-DOS with APM. If it is discharged. English 75 If you do not have the HP User Tools program installed, you can be incorrect for the following reasons: • the time has changed for more information about the...
HP Vectra XM 5/xxx Series 3 - User Guide
Page 94
...-two cache Main memory (size/speed) Video LAN Disk drive controller Rear connectors 25-pin parallel connector 9-pin serial connectors Disk drive shelves Description: PENTIUMTM 75 MHz, 90 MHz, or 120 MHz 8 KB code, 8 KB write-back data 256 KB write-through Upgradeable to 192 MB (70 ns, 32-bit or...
...-two cache Main memory (size/speed) Video LAN Disk drive controller Rear connectors 25-pin parallel connector 9-pin serial connectors Disk drive shelves Description: PENTIUMTM 75 MHz, 90 MHz, or 120 MHz 8 KB code, 8 KB write-back data 256 KB write-through Upgradeable to 192 MB (70 ns, 32-bit or...
HP Vectra XM 5/xxx Series 3 - User Guide
Page 98
... colors 256 colors 64 K colors hi-color 16.7 M colors true-color 640 x 480 1 MB 60/72/75 Hz 1 MB 60 Hz 2 MB 60/72/75 Hz 800 x 600 1 MB 56/60/72/75 Hz 1 MB 56/60 Hz 2 MB 2 MB 56/60/72/75 Hz 56/60 Hz 1024 x 768 1 MB 87i/60/70.../75 Hz 2 MB 87i/60/70/75 Hz Not Available 1280 x 1024 1 MB 87i Hz 2 MB Not Available 87i...
... colors 256 colors 64 K colors hi-color 16.7 M colors true-color 640 x 480 1 MB 60/72/75 Hz 1 MB 60 Hz 2 MB 60/72/75 Hz 800 x 600 1 MB 56/60/72/75 Hz 1 MB 56/60 Hz 2 MB 2 MB 56/60/72/75 Hz 56/60 Hz 1024 x 768 1 MB 87i/60/70.../75 Hz 2 MB 87i/60/70/75 Hz Not Available 1280 x 1024 1 MB 87i Hz 2 MB Not Available 87i...
HP Vectra XM 5/xxx Series 3 - User Guide
Page 102
... Position VR Position VRE Function: Select the VCC jumper position when you install an upgrade processor which requires Vcc voltage - (Default for PCs with Pentium 75 MHz installed) Select the VR jumper position when you install an upgrade processor which requires Vr voltage - (Default for PCs with Pentium 90 MHz installed...
... Position VR Position VRE Function: Select the VCC jumper position when you install an upgrade processor which requires Vcc voltage - (Default for PCs with Pentium 75 MHz installed) Select the VR jumper position when you install an upgrade processor which requires Vr voltage - (Default for PCs with Pentium 90 MHz installed...
HP Vectra XM 5/xxx Series 3 - User Guide
Page 114
...first time, 8 stopping, 12 unpacking, 2 using, 11-20 Plug and Play, 32 power button, 12 connector, 7 power management configuring, 18 problems, 75 understanding, 18 power supply removing, 26 replacing, 27 power-on prompt, 12 Power-On Self-Test, 62 errors, 63 screen, 8 printer configuring, 16 ...slim drive installing, 45, 49 software initializing, 8 license agreement, 9 master diskettes, 10 problems, 73 viewing license, 16 specifications technical, 81 starting HP SETUP program, 76 PC, 12 PC for the first time, 8 stopping PC, 12 support getting, 93 switch location, 90 system board, 90 jumper...
...first time, 8 stopping, 12 unpacking, 2 using, 11-20 Plug and Play, 32 power button, 12 connector, 7 power management configuring, 18 problems, 75 understanding, 18 power supply removing, 26 replacing, 27 power-on prompt, 12 Power-On Self-Test, 62 errors, 63 screen, 8 printer configuring, 16 ...slim drive installing, 45, 49 software initializing, 8 license agreement, 9 master diskettes, 10 problems, 73 viewing license, 16 specifications technical, 81 starting HP SETUP program, 76 PC, 12 PC for the first time, 8 stopping PC, 12 support getting, 93 switch location, 90 system board, 90 jumper...
HP Vectra XM 5/xxX Series 3 PC - Familiarization Guide
Page 6
...HP Vectra XM 5/xx Series 3 PC with the HP Vectra XM2 PC (integrated LAN models only) and the HP Vectra VL 5/xx Series 3 PC. Vectra Products Comparison After reading this PC. HP Vectra XM2 (D32xxA seriesintegrated LAN models only) Microprocessor 4/50i: i486 50 Mhz 4/66i: i486 66 Mhz 4/100i: i486 100 MHz HP Vectra XM 5/xx Series 3 (D348xA and D356xA series) 5/75: PentiumTM 75... 2 MB) One (use D3404A) Fast IDE controller Fast IDE controller on PCI HP Vectra VL 5/xx Series 3 (D339xA and D340xA series) 5/75: PentiumTM 75 Mhz 5/90: PentiumTM 90 Mhz 5/100: PentiumTM 100 Mhz 5/120: PentiumTM 120...
...HP Vectra XM 5/xx Series 3 PC with the HP Vectra XM2 PC (integrated LAN models only) and the HP Vectra VL 5/xx Series 3 PC. Vectra Products Comparison After reading this PC. HP Vectra XM2 (D32xxA seriesintegrated LAN models only) Microprocessor 4/50i: i486 50 Mhz 4/66i: i486 66 Mhz 4/100i: i486 100 MHz HP Vectra XM 5/xx Series 3 (D348xA and D356xA series) 5/75: PentiumTM 75... 2 MB) One (use D3404A) Fast IDE controller Fast IDE controller on PCI HP Vectra VL 5/xx Series 3 (D339xA and D340xA series) 5/75: PentiumTM 75 Mhz 5/90: PentiumTM 90 Mhz 5/100: PentiumTM 100 Mhz 5/120: PentiumTM 120...
HP Vectra XM 5/xxX Series 3 PC - Familiarization Guide
Page 11
Models The following models will be available at product launch: Platform Model Product Number PCI LAN Adapter 256 KB Cache XM 5/75 1 420 XM 5/90 1 420 840 XM 5/120 1 840 D3480A D3481A D3483A D3484A D3485A D3560A D3562A YES YES YES Async. Async. System RAM 8 MB 8 MB 8 MB Video RAM 1 MB 1 MB 1 MB HP Vectra XM 5/xx Series PC Familiarization Guide Features • 11 1 Product Overview and Async.
Models The following models will be available at product launch: Platform Model Product Number PCI LAN Adapter 256 KB Cache XM 5/75 1 420 XM 5/90 1 420 840 XM 5/120 1 840 D3480A D3481A D3483A D3484A D3485A D3560A D3562A YES YES YES Async. Async. System RAM 8 MB 8 MB 8 MB Video RAM 1 MB 1 MB 1 MB HP Vectra XM 5/xx Series PC Familiarization Guide Features • 11 1 Product Overview and Async.
HP Vectra XM 5/xxX Series 3 PC - Familiarization Guide
Page 12
...75 and 90 MHz processor multiply the 50 and 60 MHz system clock by a factor of Pentium processors, Pentium 60 MHz and 66 MHz, used by a power source of 3.3 V. HP Vectra XM 5/xx Series PC Familiarization Guide Features • 12 1 Product Overview and Microprocessor The Pentium microprocessors used in the HP Vectra XM...The Pentium 120 MHz processor doubles the 60 MHz system clock. The previous generation of 1.5. These processors are not available on the HP Vectra XM 5/xx series 3 platform at the time of the system clock. Other current and future Intel processors based upon the 66 MHz ...
...75 and 90 MHz processor multiply the 50 and 60 MHz system clock by a factor of Pentium processors, Pentium 60 MHz and 66 MHz, used by a power source of 3.3 V. HP Vectra XM 5/xx Series PC Familiarization Guide Features • 12 1 Product Overview and Microprocessor The Pentium microprocessors used in the HP Vectra XM...The Pentium 120 MHz processor doubles the 60 MHz system clock. The previous generation of 1.5. These processors are not available on the HP Vectra XM 5/xx series 3 platform at the time of the system clock. Other current and future Intel processors based upon the 66 MHz ...
HP Vectra XM 5/xxX Series 3 PC - Familiarization Guide
Page 19
... using the D3404A video memory upgrade kit (one module of 1 MB--the same module is used in the VL 5/xx series 3 PC). Video Controller The HP Vectra XM 5/xx series 3 PC has a 64-bit PCI video controller (Cirrus Logic 5434). Resolution Video Memory Required for these Colors and Refresh Rates 640 x 480 16... 1 MB 87i Hz 1 i: interlaced 2 MB 87i/60/70/ 75 Hz 1 MB 56/ 60 Hz 2 MB 56/60/72/ 75 Hz 2 MB 87i/60/70/75 Hz Not Available 16.7 M Colors True-Color 1 MB 60 Hz 2 MB 60/72/ 75 Hz 2 MB 56/60 Hz Not Available HP Vectra XM 5/xx Series PC Familiarization Guide Features • 19...
... using the D3404A video memory upgrade kit (one module of 1 MB--the same module is used in the VL 5/xx series 3 PC). Video Controller The HP Vectra XM 5/xx series 3 PC has a 64-bit PCI video controller (Cirrus Logic 5434). Resolution Video Memory Required for these Colors and Refresh Rates 640 x 480 16... 1 MB 87i Hz 1 i: interlaced 2 MB 87i/60/70/ 75 Hz 1 MB 56/ 60 Hz 2 MB 56/60/72/ 75 Hz 2 MB 87i/60/70/75 Hz Not Available 16.7 M Colors True-Color 1 MB 60 Hz 2 MB 60/72/ 75 Hz 2 MB 56/60 Hz Not Available HP Vectra XM 5/xx Series PC Familiarization Guide Features • 19...
HP Vectra XM 5/xxX Series 3 PC - Familiarization Guide
Page 38
... 60 MHz 60 MHz D3480-69001 D3483-69001 WARNING The XM 5/75 system board (D3480-69001) cannot be used with Pentium 90 or Pentium 120 processors. The XM 5/90 and XM 5/120 system board (D3483-69001) cannot be configured to correspond with the installed processor. HP Vectra XM 5/xx Series PC Familiarization Guide • 38 2 PC Hardware...
... 60 MHz 60 MHz D3480-69001 D3483-69001 WARNING The XM 5/75 system board (D3480-69001) cannot be used with Pentium 90 or Pentium 120 processors. The XM 5/90 and XM 5/120 system board (D3483-69001) cannot be configured to correspond with the installed processor. HP Vectra XM 5/xx Series PC Familiarization Guide • 38 2 PC Hardware...
HP Vectra XM 5/xxX Series 3 PC - Familiarization Guide
Page 39
...ON to retain configuration - SECURE 3 - DEFAULT • ON to prevent changes to enable passwords - Always OFF (not used) Always OFF (not used) HP Vectra XM 5/xx Series PC Familiarization Guide • 39 2 PC Hardware Structure PROCESSOR 7 - Enable or clear (and disable) User and System Administrator Passwords stored in...parity for the main memory modules. CAUTION: THE SELECTED SPEED MUST CORRESPOND WITH THE SPEED OF THE INSTALLED PROCESSOR. • OFF to select 75 MHz, 90 MHz, and 100 MHz • ON to clear configuration. DEFAULT • ON to select 120 MHz. RESERVED 8 -...
...ON to retain configuration - SECURE 3 - DEFAULT • ON to prevent changes to enable passwords - Always OFF (not used) Always OFF (not used) HP Vectra XM 5/xx Series PC Familiarization Guide • 39 2 PC Hardware Structure PROCESSOR 7 - Enable or clear (and disable) User and System Administrator Passwords stored in...parity for the main memory modules. CAUTION: THE SELECTED SPEED MUST CORRESPOND WITH THE SPEED OF THE INSTALLED PROCESSOR. • OFF to select 75 MHz, 90 MHz, and 100 MHz • ON to clear configuration. DEFAULT • ON to select 120 MHz. RESERVED 8 -...
HP Vectra XM 5/xxX Series 3 PC - Familiarization Guide
Page 50
... to 75 minutes PC Serial Number BIOS Version View the PC Serial Number View the BIOS Version Number Processor Computer speed Coprocessor Shows the type of processor in the PC. Shows the type of : Base, on system board Reserved Extended Total Confirm that the TOTAL field is correct. On/Off HP Vectra XM 5/xx...
... to 75 minutes PC Serial Number BIOS Version View the PC Serial Number View the BIOS Version Number Processor Computer speed Coprocessor Shows the type of processor in the PC. Shows the type of : Base, on system board Reserved Extended Total Confirm that the TOTAL field is correct. On/Off HP Vectra XM 5/xx...
HP Vectra XM 5/xxx Series 3 PC - Service Handbook
Page 4
HP Vectra XM 5/xxx Series 3 PC System Board, BIOS, and Memory CPU Speed/Voltage Selection Jumpers Model XM 5/75 XM 5/90 9 XM 5/100 XM 5/120 XM 5/133 Processor Part No. 5063-8786 5063-8787 5063-7024 5063-7089 5063-7974 Jumper Setting VCC VR VRE VRE VCC Warning: Pentium Overdrive processors have the same voltage as the original processor. 9-4 HP Vectra XM 5/xxx Series 3 PC Medium-Profile Desktop Vectras
HP Vectra XM 5/xxx Series 3 PC System Board, BIOS, and Memory CPU Speed/Voltage Selection Jumpers Model XM 5/75 XM 5/90 9 XM 5/100 XM 5/120 XM 5/133 Processor Part No. 5063-8786 5063-8787 5063-7024 5063-7089 5063-7974 Jumper Setting VCC VR VRE VRE VCC Warning: Pentium Overdrive processors have the same voltage as the original processor. 9-4 HP Vectra XM 5/xxx Series 3 PC Medium-Profile Desktop Vectras
HP Vectra XM 5/xxx Series 3 PC - Service Handbook
Page 5
... 6 OFF 75 MHz, 90 MHz or 100 MHz processor speed ON 120 MHz or 133 MHz processor speed 7 OFF Not used 8 OFF Not used 3 OFF EEPROM stored configuration information - Main memory can each be placed in the video memory socket (to a maximum of the same size. 9 Medium-Profile Desktop Vectras HP Vectra XM 5/xxx Series 3 PC...
... 6 OFF 75 MHz, 90 MHz or 100 MHz processor speed ON 120 MHz or 133 MHz processor speed 7 OFF Not used 8 OFF Not used 3 OFF EEPROM stored configuration information - Main memory can each be placed in the video memory socket (to a maximum of the same size. 9 Medium-Profile Desktop Vectras HP Vectra XM 5/xxx Series 3 PC...
HP Vectra XM 5/xxx Series 3 PC - Service Handbook
Page 7
... 5042-1155 5063-7066 5063-7067 5062-5590 5063-4559 02225-00010 2 Rear Bezel Connector Label 5042-1113 - 3 Nameplate: XM 5/75 5042-1139 - Medium-Profile Desktop Vectras HP Vectra XM 5/xxx Series 3 PC 9-7 XM 5/90 5042-1140 - XM 5/100 5042-1141 - XM 5/133 5042-1437 - 4 Hard Disk Drive (standard) 420 MB D2392-63001 D2392-69001 840 MB D2393-63003 D2393...
... 5042-1155 5063-7066 5063-7067 5062-5590 5063-4559 02225-00010 2 Rear Bezel Connector Label 5042-1113 - 3 Nameplate: XM 5/75 5042-1139 - Medium-Profile Desktop Vectras HP Vectra XM 5/xxx Series 3 PC 9-7 XM 5/90 5042-1140 - XM 5/100 5042-1141 - XM 5/133 5042-1437 - 4 Hard Disk Drive (standard) 420 MB D2392-63001 D2392-69001 840 MB D2393-63003 D2393...
HP Vectra XM 5/xxx Series 3 PC - Service Handbook
Page 8
... 75 MHz (Vcc) 5063-8786 - Intel Pentium 120 MHz (Vre) 5063-7089 - Main Memory Modules: 4 MB Main Memory DRAM Kit (no parity) 5063-4548 - 8 MB Main Memory DRAM Kit (no parity) 5063-4549 - Video Memory Modules (D3404A): 1 MB Video Memory Module kit 5063-7056 - 1. HP Vectra XM 5/xxx Series 3 PC System Board Parts List for HP Vectra XM 5/xxx...
... 75 MHz (Vcc) 5063-8786 - Intel Pentium 120 MHz (Vre) 5063-7089 - Main Memory Modules: 4 MB Main Memory DRAM Kit (no parity) 5063-4548 - 8 MB Main Memory DRAM Kit (no parity) 5063-4549 - Video Memory Modules (D3404A): 1 MB Video Memory Module kit 5063-7056 - 1. HP Vectra XM 5/xxx Series 3 PC System Board Parts List for HP Vectra XM 5/xxx...