HP StorageWorks Fabric OS 5.2.0b Release Notes (AA-RWEYB-TE, February 2007)
Page 9
... Switch 2.6.2c HP StorageWorks SAN Switch 2/8-EL, HP StorageWorks 3.2.1 SAN Switch 2/16, MSA SAN Switch 2/8 HP StorageWorks Core Switch 2/64 5.0.5 Recommended version 2.6.2d1 3.2.1b 5.0.5c HP StorageWorks SAN Switch 2/8V, HP StorageWorks SAN Switch 2/16V, HP StorageWorks SAN Switch 2/32, HP StorageWorks SAN Director 2/128 5.1.0b 5.2.0b HP StorageWorks 4/8 and 4/16 SAN Switch, HP StorageWorks 4/256 SAN Director HP StorageWorks 4/64 SAN Switch 5.1.0b 5.1.0 5.2.0b 5.2.0b HP StorageWorks B-Series MP Router Blade, HP StorageWorks 400 MP Router 5.1.0b 5.2.0b HP StorageWorks SAN Switch...
... Switch 2.6.2c HP StorageWorks SAN Switch 2/8-EL, HP StorageWorks 3.2.1 SAN Switch 2/16, MSA SAN Switch 2/8 HP StorageWorks Core Switch 2/64 5.0.5 Recommended version 2.6.2d1 3.2.1b 5.0.5c HP StorageWorks SAN Switch 2/8V, HP StorageWorks SAN Switch 2/16V, HP StorageWorks SAN Switch 2/32, HP StorageWorks SAN Director 2/128 5.1.0b 5.2.0b HP StorageWorks 4/8 and 4/16 SAN Switch, HP StorageWorks 4/256 SAN Director HP StorageWorks 4/64 SAN Switch 5.1.0b 5.1.0 5.2.0b 5.2.0b HP StorageWorks B-Series MP Router Blade, HP StorageWorks 400 MP Router 5.1.0b 5.2.0b HP StorageWorks SAN Switch...
HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)
Page 32
... at the same time; otherwise, fabric segmentation occurs. portcfglismode The portCfgislMode and portCfgLongDistance commands cannot both be enabled at the same time; portCfgGport On the SAN Switch 2/8-EL, a fabric license is required for two lines of command output have been added: "EMT Fabric Controller Mark Timestamp. ETP Exchange Trunking Parameter. CLI Command Updates...
... at the same time; otherwise, fabric segmentation occurs. portcfglismode The portCfgislMode and portCfgLongDistance commands cannot both be enabled at the same time; portCfgGport On the SAN Switch 2/8-EL, a fabric license is required for two lines of command output have been added: "EMT Fabric Controller Mark Timestamp. ETP Exchange Trunking Parameter. CLI Command Updates...
HP StorageWorks Web Tools V3.1.x/4.1.x User Guide (AA-RS25C-TE, June 2003)
Page 36
... requirements for the correct installation and operation of the Netscape browser running V3.1 firmware, including HP StorageWorks SAN switches 2/8, 2/8-EL, and 2/16. Note: Due to decreasing customer demand and an increasing number of significant technical incompatibilities, the combination of... required: ■ Microsoft Internet Explorer 5.5 (Service Pack 2 is no longer supported for use with HP Web Tools. Switch Requirements HP Web Tools 3.1 can be configured to work with HP Web Tools. 36 Web Tools Version 3.1.x/4.1.x User Guide Installation Requirements The workstation and the...
... requirements for the correct installation and operation of the Netscape browser running V3.1 firmware, including HP StorageWorks SAN switches 2/8, 2/8-EL, and 2/16. Note: Due to decreasing customer demand and an increasing number of significant technical incompatibilities, the combination of... required: ■ Microsoft Internet Explorer 5.5 (Service Pack 2 is no longer supported for use with HP Web Tools. Switch Requirements HP Web Tools 3.1 can be configured to work with HP Web Tools. 36 Web Tools Version 3.1.x/4.1.x User Guide Installation Requirements The workstation and the...
HP StorageWorks Web Tools V3.1.x/4.1.x User Guide (AA-RS25C-TE, June 2003)
Page 287
...Bus technologies. The IBTA is an industry consortium of six SAN Switch 16-EL switches cabled together and configured to handle traffic as a server. IOD In-order Delivery. InfiniBand defines a new channel based, switched-fabric technology for server-to-server and server-to server I... /O interconnection that collapses a loop topology into a physical star topology. Integrated Fabric The fabric created by a SAN Switch Integrated/32 and SAN Switch Integrated/64, consisting of more than 200 companies working together to develop a new common I/O specification designed to bring ...
...Bus technologies. The IBTA is an industry consortium of six SAN Switch 16-EL switches cabled together and configured to handle traffic as a server. IOD In-order Delivery. InfiniBand defines a new channel based, switched-fabric technology for server-to-server and server-to server I... /O interconnection that collapses a loop topology into a physical star topology. Integrated Fabric The fabric created by a SAN Switch Integrated/32 and SAN Switch Integrated/64, consisting of more than 200 companies working together to develop a new common I/O specification designed to bring ...
HP StorageWorks Zoning V3.1.x/4.1.x User Guide (AA-RS26C-TE, June 2003)
Page 87
...for server-to-server and server-to handle traffic as a server. See also Target. The IBTA is an industry consortium of six SAN Switch 16-EL switches cabled together and configured to -I /O. Initiator A server or workstation on a Fibre Channel network that collapses a loop topology into a ...added to keep the link active and maintain bit, byte, and word synchronization. Integrated Fabric The fabric created by a SAN Switch Integrated/32 and SAN Switch Integrated/64, consisting of more than 200 companies working together to develop a new common I/O specification designed to bring ...
...for server-to-server and server-to handle traffic as a server. See also Target. The IBTA is an industry consortium of six SAN Switch 16-EL switches cabled together and configured to -I /O. Initiator A server or workstation on a Fibre Channel network that collapses a loop topology into a ...added to keep the link active and maintain bit, byte, and word synchronization. Integrated Fabric The fabric created by a SAN Switch Integrated/32 and SAN Switch Integrated/64, consisting of more than 200 companies working together to develop a new common I/O specification designed to bring ...
Fabric OS V3.1.1C Release Notes
Page 4
...; HP StorageWorks SAN Switch 2/8 and 2/8 EL ■ HP StorageWorks SAN Switch 2/16 and 2/16 EL Supported configurations For the latest supported configurations, please refer to the SAN Design Reference Guide, available at: http://h18000.www1.hp.com/products/storageworks/san/documentation.html Related documentation Related documentation includes the following documents: ■ HP StorageWorks SAN Switch 2/8 Version 3.1.x Installation Guide, AA-RSB6C-TE ■ HP StorageWorks SAN Switch 2/8 Version 3.1.x Release Notes, AV-RSB7C-TE ■ HP StorageWorks SAN Switch 2/16 Version...
...; HP StorageWorks SAN Switch 2/8 and 2/8 EL ■ HP StorageWorks SAN Switch 2/16 and 2/16 EL Supported configurations For the latest supported configurations, please refer to the SAN Design Reference Guide, available at: http://h18000.www1.hp.com/products/storageworks/san/documentation.html Related documentation Related documentation includes the following documents: ■ HP StorageWorks SAN Switch 2/8 Version 3.1.x Installation Guide, AA-RSB6C-TE ■ HP StorageWorks SAN Switch 2/8 Version 3.1.x Release Notes, AV-RSB7C-TE ■ HP StorageWorks SAN Switch 2/16 Version...
Fabric OS V3.1.1C Release Notes
Page 13
.... Fabric OS 3.1.1c Release Notes 13 configdefault command warning HP advises against using the configdefault command. Locate the HP StorageWorks SAN Switch Software CD that the device connected to the switch. For the SAN Switch 2/8, 2/8 EL, 2/16, or 2/16 EL Switches To reapply both the default HP-specific Fabric Watch parameters and the default HP-specific configuration parameters: 1. Note: All of the firmwareDownload command, please...
.... Fabric OS 3.1.1c Release Notes 13 configdefault command warning HP advises against using the configdefault command. Locate the HP StorageWorks SAN Switch Software CD that the device connected to the switch. For the SAN Switch 2/8, 2/8 EL, 2/16, or 2/16 EL Switches To reapply both the default HP-specific Fabric Watch parameters and the default HP-specific configuration parameters: 1. Note: All of the firmwareDownload command, please...
Fabric OS V3.1.1C Release Notes
Page 14
...en-us ;242167&. Clicking a tree node will cause the right panels to update to change : route.delayReroute:1 2. For the HP StorageWorks SAN Switch 2/16 and 2/16 EL, use a single instance of the SwitchExplorer on Windows NT 4.0: Normally, when you can obtain a workaround directly from Microsoft for this...242167&. 14 Fabric OS 3.1.1c Release Notes For the HP StorageWorks SAN Switch 2/8 and 2/8 EL, use the manual procedure below to reload HP default settings. Use the configdownload command to download the configuration file to reload HP default settings. If you do not want to load ...
...en-us ;242167&. Clicking a tree node will cause the right panels to update to change : route.delayReroute:1 2. For the HP StorageWorks SAN Switch 2/16 and 2/16 EL, use a single instance of the SwitchExplorer on Windows NT 4.0: Normally, when you can obtain a workaround directly from Microsoft for this...242167&. 14 Fabric OS 3.1.1c Release Notes For the HP StorageWorks SAN Switch 2/8 and 2/8 EL, use the manual procedure below to reload HP default settings. Use the configdownload command to download the configuration file to reload HP default settings. If you do not want to load ...
HP StorageWorks Fabric OS V3.2.1 Release Notes (AA-RUQYF-TE, January 2006)
Page 10
... be added to the ambient air temperature at the air intake vents on the nonport side of the switch. HP StorageWorks SAN Switch 2/8 EL installation guide, PN: AA-RSB6B-TE • On page 87, Table 8: • The Temperature condition refers to the Port Status LED information .... • On page 64, Table 4: • The following statement should be up to 75 degrees Celsius (167 degrees F) during switch operation. HP StorageWorks SAN Switch 2/16 installation guide, PN: AA-RR84B-TE • On page 92, Table 8: • The Temperature condition refers to the ambient air temperature at ...
... be added to the ambient air temperature at the air intake vents on the nonport side of the switch. HP StorageWorks SAN Switch 2/8 EL installation guide, PN: AA-RSB6B-TE • On page 87, Table 8: • The Temperature condition refers to the Port Status LED information .... • On page 64, Table 4: • The following statement should be up to 75 degrees Celsius (167 degrees F) during switch operation. HP StorageWorks SAN Switch 2/16 installation guide, PN: AA-RR84B-TE • On page 92, Table 8: • The Temperature condition refers to the ambient air temperature at ...
HP StorageWorks Fabric OS V3.2.1c Release Notes (AA-RUQYH-TE, June 2007)
Page 3
.... • After executing switchDisable or switchEnable in a large secure fabric, some SAN Switch 2/16 models experienced queue overflow and rebooted. • During in-house testing on the following switches only: • HP StorageWorks MSA SAN Switch 2/8 (SilkWorm 3000) • HP StorageWorks SAN Switch 2/16 (SilkWorm 3800) • HP StorageWorks SAN Switch 2/8-EL (SilkWorm 3200) • HP StorageWorks SAN Switch 2/16-EL (SilkWorm 3600) Fabric OS 3.2.1b fixes The following defects have...
.... • After executing switchDisable or switchEnable in a large secure fabric, some SAN Switch 2/16 models experienced queue overflow and rebooted. • During in-house testing on the following switches only: • HP StorageWorks MSA SAN Switch 2/8 (SilkWorm 3000) • HP StorageWorks SAN Switch 2/16 (SilkWorm 3800) • HP StorageWorks SAN Switch 2/8-EL (SilkWorm 3200) • HP StorageWorks SAN Switch 2/16-EL (SilkWorm 3600) Fabric OS 3.2.1b fixes The following defects have...
quickloop fabric assist version 3.0.x user guide
Page 12
...to a single port) that looplet. Standard translative mode is available as the SAN grows, fabric switches can be used to the ports of one loop. In this scenario, QuickLoop-enabled switches can be configured to consist of selected devices or looplets connected to replace ... not fabric-aware. Also allows a private host to communicate with deploying a single private loop and later deploying a fabric-based SAN. QuickLoop allows a SAN Switch 8-EL/16-EL to a fabric. All devices in the same QuickLoop. It is transparent and requires no actions on the part of connectivity to...
...to a single port) that looplet. Standard translative mode is available as the SAN grows, fabric switches can be used to the ports of one loop. In this scenario, QuickLoop-enabled switches can be configured to consist of selected devices or looplets connected to replace ... not fabric-aware. Also allows a private host to communicate with deploying a single private loop and later deploying a fabric-based SAN. QuickLoop allows a SAN Switch 8-EL/16-EL to a fabric. All devices in the same QuickLoop. It is transparent and requires no actions on the part of connectivity to...
quickloop fabric assist version 3.0.x user guide
Page 35
...back to be on higher-level protocols for SCN, and without causing a configuration change, then no RSCN will not register for error recovery. A switch with a private target is configured to the loop's Fabric Assist targets. A Registered State Change Notification (RSCN) will not allow any of any ...port of the Fabric Assist zone. If LIP propagation to the private target's loop when the first ELS command is running QuickLoop. Quickloop Fabric Assist User Guide 35 Private hosts LIP only when phantoms are Fabric Assist zoned. If Fabric Assist...
...back to be on higher-level protocols for SCN, and without causing a configuration change, then no RSCN will not register for error recovery. A switch with a private target is configured to the loop's Fabric Assist targets. A Registered State Change Notification (RSCN) will not allow any of any ...port of the Fabric Assist zone. If LIP propagation to the private target's loop when the first ELS command is running QuickLoop. Quickloop Fabric Assist User Guide 35 Private hosts LIP only when phantoms are Fabric Assist zoned. If Fabric Assist...
quickloop fabric assist version 3.0.x user guide
Page 65
...public devices to the E_Port of a Fibre Channel Services request. Integrated Fabric The fabric created by a Compaq StorageWorks Fibre Channel SAN Switch IS/32 or IS/64, or SAN Switches 16-EL/8-EL switches cabled together and configured to the loop when active and removed when inactive. See also Target. a Fibre... Channel link from the E_Port of one switch to communicate with a process at an N_Port. Nodes are not in ...
...public devices to the E_Port of a Fibre Channel Services request. Integrated Fabric The fabric created by a Compaq StorageWorks Fibre Channel SAN Switch IS/32 or IS/64, or SAN Switches 16-EL/8-EL switches cabled together and configured to the loop when active and removed when inactive. See also Target. a Fibre... Channel link from the E_Port of one switch to communicate with a process at an N_Port. Nodes are not in ...
HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Page 1
This document is an addendum for Fabric OS users to Fabric OS version 3.x and all switches running Fabric OS version 3.x, including the HP StorageWorks SAN Switch 2/8 EL, SAN Switch 2/16, and MSA SAN Switch 2/8. document addendum HP StorageWorks Fabric OS 3.x First Edition (January 2005) Part Number: AA-RW24A-TE This document is specific to supplement the Fabric OS version 3.x documentation set.
This document is an addendum for Fabric OS users to Fabric OS version 3.x and all switches running Fabric OS version 3.x, including the HP StorageWorks SAN Switch 2/8 EL, SAN Switch 2/16, and MSA SAN Switch 2/8. document addendum HP StorageWorks Fabric OS 3.x First Edition (January 2005) Part Number: AA-RW24A-TE This document is specific to supplement the Fabric OS version 3.x documentation set.
HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Page 9
... uupiddatees since the last release of the 3.x documentation set, for the following HP StorageWorks switches: About this Guide ■ HP StorageWorks SAN Switch 2/8 EL ■ HP StorageWorks SAN Switch 2/16 ■ HP StorageWorks MSA SAN Switch 2/8 For example, this Addendum apply if you are running Fabric OS 3.1.x or later. This preface contains the following documents: ■ HP StorageWorks Advanced Performance Monitor Version 3.1.x/4.1.x User Guide, part number AA-RTS4C-TE...
... uupiddatees since the last release of the 3.x documentation set, for the following HP StorageWorks switches: About this Guide ■ HP StorageWorks SAN Switch 2/8 EL ■ HP StorageWorks SAN Switch 2/16 ■ HP StorageWorks MSA SAN Switch 2/8 For example, this Addendum apply if you are running Fabric OS 3.1.x or later. This preface contains the following documents: ■ HP StorageWorks Advanced Performance Monitor Version 3.1.x/4.1.x User Guide, part number AA-RTS4C-TE...
HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Page 10
...the web page. 2. The switch overview page displays. 5. Documentation, including white papers and best practices documents, is intended for example SAN Switch 2/16, SAN Switch 2/8 EL, or MSA SAN Switch 2/8 models. About this document...), select the appropriate product, for users of the Fabric OS version 3.1.x/4.1.x documentation set. Related documentation Related documents are listed on -screen instructions to the By type subsection. 3. Locate the Fibre Channel Switches section. Go to : http://www.hp...
...the web page. 2. The switch overview page displays. 5. Documentation, including white papers and best practices documents, is intended for example SAN Switch 2/16, SAN Switch 2/8 EL, or MSA SAN Switch 2/8 models. About this document...), select the appropriate product, for users of the Fabric OS version 3.1.x/4.1.x documentation set. Related documentation Related documents are listed on -screen instructions to the By type subsection. 3. Locate the Fibre Channel Switches section. Go to : http://www.hp...
HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Page 74
Zoning version user guide On page 30, under the heading "Detailed Zone Configuration Procedures," add the following: Table 11 presents zoning database size limitations for various Fabric OS release versions. Table 11: Zoning Database Limitations Fabric OS Version 2.4.0 2.5.0 2.6.0 3.0.0 3.1.0 3.2.x 4.0.0, 4.1.0, 4.2.0 4.4.0 Maximum Database Size (KB) 64 64 96 128 96 256 128 256 Note: Zoning databases larger than 96 KB are not supported on SAN Switch 2/8 EL and SAN Switch 2/16 with 16 MB of memory. 74 Fabric OS 3.x Document Addendum
Zoning version user guide On page 30, under the heading "Detailed Zone Configuration Procedures," add the following: Table 11 presents zoning database size limitations for various Fabric OS release versions. Table 11: Zoning Database Limitations Fabric OS Version 2.4.0 2.5.0 2.6.0 3.0.0 3.1.0 3.2.x 4.0.0, 4.1.0, 4.2.0 4.4.0 Maximum Database Size (KB) 64 64 96 128 96 256 128 256 Note: Zoning databases larger than 96 KB are not supported on SAN Switch 2/8 EL and SAN Switch 2/16 with 16 MB of memory. 74 Fabric OS 3.x Document Addendum
HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Page 80
... OS 3.x Document Addendum The error code value is for internal use only. For the HP StorageWorks SAN Switch 2/8 EL, replace the entire switch. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. This usually indicates an ASIC failure. Recommended Action For the HP StorageWorks SAN Switch 2/16, replace the motherboard FRU. This usually indicates an ASIC failure.
... OS 3.x Document Addendum The error code value is for internal use only. For the HP StorageWorks SAN Switch 2/8 EL, replace the entire switch. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. This usually indicates an ASIC failure. Recommended Action For the HP StorageWorks SAN Switch 2/16, replace the motherboard FRU. This usually indicates an ASIC failure.
HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Page 81
... was a software operational setup error or motherboard failure. ■ There occurred a retry, reboot, or replacement of the following reasons: ■ Switch is not disabled. ■ Diagnostic queue is absent. ■ Malloc failed. ■ Chip is not present. ■ Port is not ... Init: , Err# Probable Cause A port failed to initialize due to one of motherboard assembly. For the SAN Switch 2/8 EL, replace the entire switch. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. The error code value is for internal use only. Diagnostic and system error messages ...
... was a software operational setup error or motherboard failure. ■ There occurred a retry, reboot, or replacement of the following reasons: ■ Switch is not disabled. ■ Diagnostic queue is absent. ■ Malloc failed. ■ Chip is not present. ■ Port is not ... Init: , Err# Probable Cause A port failed to initialize due to one of motherboard assembly. For the SAN Switch 2/8 EL, replace the entire switch. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. The error code value is for internal use only. Diagnostic and system error messages ...
HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW24A-TE, January 2005)
Page 82
... camtest command. This message is generated by the camtest command. Recommended Action Check for internal use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. Severity CRITICAL DIAG-CAMSID Message CRITICAL DIAG-CAMSID, 1, , pass , Pt Failed SID [No] ... for a faulty cable or deteriorated SFP. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. The error code value is for internal use only. Diagnostic and system error messages reference guide...
... camtest command. This message is generated by the camtest command. Recommended Action Check for internal use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. Severity CRITICAL DIAG-CAMSID Message CRITICAL DIAG-CAMSID, 1, , pass , Pt Failed SID [No] ... for a faulty cable or deteriorated SFP. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. The error code value is for internal use only. Diagnostic and system error messages reference guide...