Brocade Fabric OS Administrator's Guide v6.3.0 (53-1001336-01, July 2009)
Page 334
... SAN already has Fabric OS and M-EOS switches and you can have devices directly attached that have switches from different vendors. AG uses N_Port Virtualization (NPIV) functionality in Brocade embedded switches ...McDATA Open Fabric mode is intended specifically for example, Mi10K, M6140, M6064, and the DCX Backbone platform. Fabrics containing only Fabric OS switches in Open Fabric mode are having... while keeping the fabrics separate or unmerged. The Brocade 7500 and 7500E Extension switches, the Brocade 7800 switch, and the Brocade FR4-18i and FX8-24 application blades can use...
... SAN already has Fabric OS and M-EOS switches and you can have devices directly attached that have switches from different vendors. AG uses N_Port Virtualization (NPIV) functionality in Brocade embedded switches ...McDATA Open Fabric mode is intended specifically for example, Mi10K, M6140, M6064, and the DCX Backbone platform. Fabrics containing only Fabric OS switches in Open Fabric mode are having... while keeping the fabrics separate or unmerged. The Brocade 7500 and 7500E Extension switches, the Brocade 7800 switch, and the Brocade FR4-18i and FX8-24 application blades can use...
Brocade Web Tools Administrator's Guide v6.3.0 (53-1001343-01, July 2009)
Page 168
... that contain hosts and targets that assigns a Quality of Service (QoS) level for a specific traffic flow. The formats and meaning of fabric-connected devices, and devices can be identified by...necessarily unique across fabrics. Zones can belong to more than partitioning access to storage. Extension switches like the 7500 provide multiple mechanisms to differentiate it from a regular zone. TABLE...storage. 9 Zoning overview Basic Zones Basic zoning enables you to partition a storage area network (SAN) into two zones, winzone and unixzone, so that the Windows servers and storage do not...
... that contain hosts and targets that assigns a Quality of Service (QoS) level for a specific traffic flow. The formats and meaning of fabric-connected devices, and devices can be identified by...necessarily unique across fabrics. Zones can belong to more than partitioning access to storage. Extension switches like the 7500 provide multiple mechanisms to differentiate it from a regular zone. TABLE...storage. 9 Zoning overview Basic Zones Basic zoning enables you to partition a storage area network (SAN) into two zones, winzone and unixzone, so that the Windows servers and storage do not...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 9
..., and required actions 75 16 Management tools 81 17 8-Gb SAN Switch physical dimensions 83 18 8/8, 8/24 and 8/40 SAN Switch memory 84 19 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory ...84 20 1606 Extension SAN Switch memory 84 21 Facility requirements 84 22 EMC ...85 23 Power supply specifications 86 24 Laser data transmission ranges for the 8/8 and...
..., and required actions 75 16 Management tools 81 17 8-Gb SAN Switch physical dimensions 83 18 8/8, 8/24 and 8/40 SAN Switch memory 84 19 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory ...84 20 1606 Extension SAN Switch memory 84 21 Facility requirements 84 22 EMC ...85 23 Power supply specifications 86 24 Laser data transmission ranges for the 8/8 and...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 83
... SAN Switch physical dimensions Property 8/8 and 8/24 8/40 SAN SAN Switches Switch Height 4.29 cm nl (1.69 inches) 1U = 4.3 cm nl (1.7 inches) 8/80 SAN Switch 2U = 8.6 cm nl (3.4 inches) Encryption SAN Switch FCoE nl Converged nl Network nl Switch 2U = 8.6 cm nl (3.34 inches) 1U = 4.3 cm nl (1.7 inches) 1606 Extension SAN Switch... supply/fan assemblies, no SFPs) Memory Table 18 lists 8/8, 8/24, and 8/40 SAN Switch memory specifications. 8-Gb SAN Switch Hardware Reference Guide 83 4 Technical specifications Weight and physical dimensions Table 17 lists the physical dimensions for the...
... SAN Switch physical dimensions Property 8/8 and 8/24 8/40 SAN SAN Switches Switch Height 4.29 cm nl (1.69 inches) 1U = 4.3 cm nl (1.7 inches) 8/80 SAN Switch 2U = 8.6 cm nl (3.4 inches) Encryption SAN Switch FCoE nl Converged nl Network nl Switch 2U = 8.6 cm nl (3.34 inches) 1U = 4.3 cm nl (1.7 inches) 1606 Extension SAN Switch... supply/fan assemblies, no SFPs) Memory Table 18 lists 8/8, 8/24, and 8/40 SAN Switch memory specifications. 8-Gb SAN Switch Hardware Reference Guide 83 4 Technical specifications Weight and physical dimensions Table 17 lists the physical dimensions for the...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 84
... the 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory specifications. input line frequency 47-63 Hz. Table 19 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory Memory type Install memory Main Memory (DDR2 SDRAM) Boot Flash Compact Flash 1 GB 4 MB 1 GB Table 20 lists the 1606 Extension SAN Switch memory specifications. switch autosenses input voltage. 8/40 SAN Switch-Primary AC input...
... the 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory specifications. input line frequency 47-63 Hz. Table 19 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory Memory type Install memory Main Memory (DDR2 SDRAM) Boot Flash Compact Flash 1 GB 4 MB 1 GB Table 20 lists the 1606 Extension SAN Switch memory specifications. switch autosenses input voltage. 8/40 SAN Switch-Primary AC input...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 86
in-rush current: less than 60 A peak 1606 Extension SAN Switch (one power supply); Table 23 Power supply specifications Specification Description Inlet C13 Maximum output from each power supply 8/8 and 8/24 SAN Switches: 75 W, with fans operating 8/40 SAN Switch: 125 W, with fans operating 8/80 SAN Switch: 300 W, with fans operating Encryption SAN Switch and FCoE Converged Network Switch: 350 W DC (one power supply): 150 watts...
in-rush current: less than 60 A peak 1606 Extension SAN Switch (one power supply); Table 23 Power supply specifications Specification Description Inlet C13 Maximum output from each power supply 8/8 and 8/24 SAN Switches: 75 W, with fans operating 8/40 SAN Switch: 125 W, with fans operating 8/80 SAN Switch: 300 W, with fans operating Encryption SAN Switch and FCoE Converged Network Switch: 350 W DC (one power supply): 150 watts...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 90
Table 28 Laser data transmission ranges for the 1606 Extension SAN Switch Fibre Channel ports Port speed 1 Gb/s Cable size nl (microns) 50 Short wavelength Long wavelength 500 m (1,640 ft) (OM2) 860 m (2,821 ft) ...for the 1606 Extension SAN Switch Port speed 1 Gb/s Cable size nl (microns) 50 Short wavelength Long wavelength 500 m (1,640 ft) (OM2) 860 m (2,821 ft) (OM3) N/A 90 Technical specifications Port speed Cable size nl (microns) Short wavelength Long wavelength (Encryption SAN Switch) Long wavelength (FCoE Converged Network Switch) NOTE: For the Encryption SAN Switch and ...
Table 28 Laser data transmission ranges for the 1606 Extension SAN Switch Fibre Channel ports Port speed 1 Gb/s Cable size nl (microns) 50 Short wavelength Long wavelength 500 m (1,640 ft) (OM2) 860 m (2,821 ft) ...for the 1606 Extension SAN Switch Port speed 1 Gb/s Cable size nl (microns) 50 Short wavelength Long wavelength 500 m (1,640 ft) (OM2) 860 m (2,821 ft) (OM3) N/A 90 Technical specifications Port speed Cable size nl (microns) Short wavelength Long wavelength (Encryption SAN Switch) Long wavelength (FCoE Converged Network Switch) NOTE: For the Encryption SAN Switch and ...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010)
Page 119
..., setting, 46 ipaddrshow command, 47 ISL trunking groups, 26 L LEDs 1606 Extension SAN switch, 67 8/24 SAN switch, 56 8/40 SAN Switch, 57 8/8 SAN switch, 56 8/80 SAN switch, 58 Encryption SAN switch, 62 fan assembly, 75 FCoE Converged Network switch , licenseadd command, 26 licenseshow command, 26 local time synchronizing, 50 M management features, 80 memory specifications, 83 monitoring topology, 80 N notices battery replacement, 100 Japanese power...
..., setting, 46 ipaddrshow command, 47 ISL trunking groups, 26 L LEDs 1606 Extension SAN switch, 67 8/24 SAN switch, 56 8/40 SAN Switch, 57 8/8 SAN switch, 56 8/80 SAN switch, 58 Encryption SAN switch, 62 fan assembly, 75 FCoE Converged Network switch , licenseadd command, 26 licenseshow command, 26 local time synchronizing, 50 M management features, 80 memory specifications, 83 monitoring topology, 80 N notices battery replacement, 100 Japanese power...
HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, April 2010)
Page 7
...1606 Extension SAN Switch must have the Port Upgrade license installed to create ICL connections between two DC SAN Backbone Director chassis, without consuming valuable front-end 8-Gb ports. Application-specific traffic flows can support only 8 links on a DC04 SAN... SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to be configured, prioritized, and optimized throughout the data center infrastructure. • 1606 Extension SAN Switch Port Upgrade-This new license allows a 1606 Extension SAN Switch ...
...1606 Extension SAN Switch must have the Port Upgrade license installed to create ICL connections between two DC SAN Backbone Director chassis, without consuming valuable front-end 8-Gb ports. Application-specific traffic flows can support only 8 links on a DC04 SAN... SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to be configured, prioritized, and optimized throughout the data center infrastructure. • 1606 Extension SAN Switch Port Upgrade-This new license allows a 1606 Extension SAN Switch ...
HP StorageWorks Fabric OS 6.3.0 release notes (5697-0358, April 2010)
Page 15
... for specific HP support of interop fabrics. 3 HP strongly ...HP StorageWorks SAN Director 48 Port 8-Gb FC Blade (FC8-48) 6.1.0f 6.3.0 HP StorageWorks SAN Director 6 Port 10-Gb ISL Blade (FC10-6) 6.1.0f 6.3.0 HP StorageWorks 8/8 SAN Switch HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 6.1.0f 6.3.05 HP StorageWorks Encryption SAN Switch 6.2.0b 6.3.0 HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) 6.3.0 HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000) 6.1.2_cee1 HP StorageWorks DC SAN Director Switch...
... for specific HP support of interop fabrics. 3 HP strongly ...HP StorageWorks SAN Director 48 Port 8-Gb FC Blade (FC8-48) 6.1.0f 6.3.0 HP StorageWorks SAN Director 6 Port 10-Gb ISL Blade (FC10-6) 6.1.0f 6.3.0 HP StorageWorks 8/8 SAN Switch HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 6.1.0f 6.3.05 HP StorageWorks Encryption SAN Switch 6.2.0b 6.3.0 HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) 6.3.0 HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000) 6.1.2_cee1 HP StorageWorks DC SAN Director Switch...
HP StorageWorks Fabric OS 6.3.0a release notes (5697-0359, April 2010)
Page 8
Application-specific traffic flows can be configured, prioritized, and optimized throughout the data center infrastructure. • 1606 Extension SAN Switch Port Upgrade-This new license allows a 1606 Extension SAN Switch to enable 16 FC ports (instead of the base 4 ports) and 6 GbE ports ... FICON. • Advanced Extension-This new license enables two advanced extension features: FCIP Trunking and Adaptive Rate Limiting (ARL). This license is included with all HP StorageWorks DC Switch Encryption blades installed in the DC SAN Backbone Director/DC04 SAN Director chassis. • Server...
Application-specific traffic flows can be configured, prioritized, and optimized throughout the data center infrastructure. • 1606 Extension SAN Switch Port Upgrade-This new license allows a 1606 Extension SAN Switch to enable 16 FC ports (instead of the base 4 ports) and 6 GbE ports ... FICON. • Advanced Extension-This new license enables two advanced extension features: FCIP Trunking and Adaptive Rate Limiting (ARL). This license is included with all HP StorageWorks DC Switch Encryption blades installed in the DC SAN Backbone Director/DC04 SAN Director chassis. • Server...
HP StorageWorks Fabric OS 6.3.0a release notes (5697-0359, April 2010)
Page 15
... Port 8-Gb FC Blade (FC8-32) HP StorageWorks SAN Director 48 Port 8-Gb FC Blade (FC8-48) 6.1.0f 6.3.0a HP StorageWorks SAN Director 6 Port 10-Gb ISL Blade (FC10-6) 6.1.0f 6.3.0a HP StorageWorks 8/8 SAN Switch HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 6.1.0f 6.3.0a5 HP StorageWorks Encryption SAN Switch 6.2.0b 6.3.0a HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) 6.3.0 HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000) 6.1.2_cee1 HP StorageWorks DC SAN Director Switch 10/24 FCoE Blade (Brocade FCOE10...
... Port 8-Gb FC Blade (FC8-32) HP StorageWorks SAN Director 48 Port 8-Gb FC Blade (FC8-48) 6.1.0f 6.3.0a HP StorageWorks SAN Director 6 Port 10-Gb ISL Blade (FC10-6) 6.1.0f 6.3.0a HP StorageWorks 8/8 SAN Switch HP StorageWorks 8/24 SAN Switch HP StorageWorks 8/40 SAN Switch HP StorageWorks 8/80 SAN Switch 6.1.0f 6.3.0a5 HP StorageWorks Encryption SAN Switch 6.2.0b 6.3.0a HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) 6.3.0 HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000) 6.1.2_cee1 HP StorageWorks DC SAN Director Switch 10/24 FCoE Blade (Brocade FCOE10...
HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361, April 2010)
Page 7
...ICL 16 link)-Provides dedicated high-bandwidth links between two DC SAN Backbone Director chassis, without consuming valuable front-end 8-Gb ports. This license includes the Top Talkers feature. • High-Performance Extension over virtually unlimited distance for the 400 MP Router and ... for B-series and M-series interop fabrics, see the HP StorageWorks Merging Fabrics Based on M-series and B-series Fibre Channel Switches Application Notes. Each DC Backbone Director must be up to the FCoE VLAN is dropped. NOTE: For specific information on HP support for port access control.
...ICL 16 link)-Provides dedicated high-bandwidth links between two DC SAN Backbone Director chassis, without consuming valuable front-end 8-Gb ports. This license includes the Top Talkers feature. • High-Performance Extension over virtually unlimited distance for the 400 MP Router and ... for B-series and M-series interop fabrics, see the HP StorageWorks Merging Fabrics Based on M-series and B-series Fibre Channel Switches Application Notes. Each DC Backbone Director must be up to the FCoE VLAN is dropped. NOTE: For specific information on HP support for port access control.
HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361, April 2010)
Page 8
... on a DC SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to provide a high-bandwidth FCIP tunnel and failover resiliency. The QoS SID/DID Prioritization and Ingress Rate Limiting features are available on all 8-Gb platforms. • Integrated Routing license-Allows ports on the DC SAN Director Multiprotocol Extension Blade. Application-specific traffic flows can...
... on a DC SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to provide a high-bandwidth FCIP tunnel and failover resiliency. The QoS SID/DID Prioritization and Ingress Rate Limiting features are available on all 8-Gb platforms. • Integrated Routing license-Allows ports on the DC SAN Director Multiprotocol Extension Blade. Application-specific traffic flows can...
HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361, April 2010)
Page 32
... in the Command Reference Guide for more information on mirror port configuration and requirements. 10G interoperability 10G interoperability between the HP StorageWorks SAN Director 6 Port 10Gb FC Blade and McDATA blades is not supported due to a hardware limitation. All ports on...1606 Extension SAN Switch. • See the portMirror command in the Default Logical Switch. However, the SAN Director 6 Port 10Gb FC Blade is going offline may not be assigned to a user-defined Logical Switch to a nondefault logical switch operating with M-EOS platforms. NOTE: For information about specific...
... in the Command Reference Guide for more information on mirror port configuration and requirements. 10G interoperability 10G interoperability between the HP StorageWorks SAN Director 6 Port 10Gb FC Blade and McDATA blades is not supported due to a hardware limitation. All ports on...1606 Extension SAN Switch. • See the portMirror command in the Default Logical Switch. However, the SAN Director 6 Port 10Gb FC Blade is going offline may not be assigned to a user-defined Logical Switch to a nondefault logical switch operating with M-EOS platforms. NOTE: For information about specific...
HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, April 2010)
Page 6
...which F_Ports are any slow-draining devices causing network congestion. NOTE: For specific information HP support for the port to investigate the problem. FCR enhancements • EX_Port...3 can view historic statistics logs for B-series and M-series interop fabrics, see the HP StorageWorks Merging Fabrics Based on all of the slave ports becomes the new master port, and...FOS 6.3.0a and later. • Adaptive Rate Limiting (ARL)-The DC SAN Director Multiprotocol Extension Blade and 1606 Extension SAN Switch allow an FCIP tunnel connection to dynamically change with the master port offline...
...which F_Ports are any slow-draining devices causing network congestion. NOTE: For specific information HP support for the port to investigate the problem. FCR enhancements • EX_Port...3 can view historic statistics logs for B-series and M-series interop fabrics, see the HP StorageWorks Merging Fabrics Based on all of the slave ports becomes the new master port, and...FOS 6.3.0a and later. • Adaptive Rate Limiting (ARL)-The DC SAN Director Multiprotocol Extension Blade and 1606 Extension SAN Switch allow an FCIP tunnel connection to dynamically change with the master port offline...
HP StorageWorks FOS 6.3.0b Release Notes (5697-0360, April 2010)
Page 8
...Encryption Performance License enables full encryption processing power on the HP StorageWorks Encryption SAN Switch or on a DC SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to the server infrastructure. The ARL feature provides a minimum... a TCP connection. Application-specific traffic flows can be configured, prioritized, and optimized throughout the data center infrastructure. • 1606 Extension SAN Switch Port Upgrade-This new license allows a 1606 Extension SAN Switch to 10 1-GbE ports ...
...Encryption Performance License enables full encryption processing power on the HP StorageWorks Encryption SAN Switch or on a DC SAN Backbone Director, DC04 SAN Director, 1606 Extension SAN Switch, HP StorageWorks 8/80 SAN Switch, or HP StorageWorks 8/40 SAN Switch to the server infrastructure. The ARL feature provides a minimum... a TCP connection. Application-specific traffic flows can be configured, prioritized, and optimized throughout the data center infrastructure. • 1606 Extension SAN Switch Port Upgrade-This new license allows a 1606 Extension SAN Switch to 10 1-GbE ports ...
HP StorageWorks 1606 Extension SAN Switch quick start instructions (AP862-96001, October 2009)
Page 1
... server for more information on the workstation. b. To set up and configure the HP StorageWorks 1606 Extension SAN Switch. Disable any serial communication programs running on supported transceivers. Figure 1 Port side of the switch are free of the 1606 SAN Switch. For specific power supply information, see the HP StorageWorks 8Gb SAN Switch hardware reference guide. The power supply LEDs are adequate, as HyperTerminal) •...
... server for more information on the workstation. b. To set up and configure the HP StorageWorks 1606 Extension SAN Switch. Disable any serial communication programs running on supported transceivers. Figure 1 Port side of the switch are free of the 1606 SAN Switch. For specific power supply information, see the HP StorageWorks 8Gb SAN Switch hardware reference guide. The power supply LEDs are adequate, as HyperTerminal) •...