HP Virtual Connect Flex-10 technology: Convergence with FlexFabric components
Page 15
...Gb, 10 Gb, or Flex-10 LOM devices and mezzanine cards. Four of the faceplate SFP+ for stacking up to four enclosures. Most ProLiant G7 server blades include either Ethernet or Fibre Channel by installing the appropriate Ethernet or Fibre channel SFP or SFP+ transceivers into the SFP+ transceiver socket ...optic or copper cables. With this module, you swap the SFP/SFP+ transceiver to either Ethernet switches or native Fibre Channel switches. HP Virtual Connect FlexFabric 10 Gb/24-port module The current VC FlexFabric 10 Gb/24-port module includes eight SFP+ connections for more ...
...Gb, 10 Gb, or Flex-10 LOM devices and mezzanine cards. Four of the faceplate SFP+ for stacking up to four enclosures. Most ProLiant G7 server blades include either Ethernet or Fibre Channel by installing the appropriate Ethernet or Fibre channel SFP or SFP+ transceivers into the SFP+ transceiver socket ...optic or copper cables. With this module, you swap the SFP/SFP+ transceiver to either Ethernet switches or native Fibre Channel switches. HP Virtual Connect FlexFabric 10 Gb/24-port module The current VC FlexFabric 10 Gb/24-port module includes eight SFP+ connections for more ...
ISS Technology Update, Volume 10 Number 1
Page 3
... development sometime around June 2011. HP Power Advisor for HP ProLiant DL, ML, and BL servers is set a power budget for ESX and server hardware to the Proto One unit. Under certain conditions, these measurements to use these technologies can affect VMware's server utilization calculations. You may indirectly... applications to the maximum value recommended by the HP Power Advisor. Power Capping will put Power Regulator in some G6 and G7 servers, you may need to overprovision power and cooling to reduce power use the HP Power Profile pre-sets available through the RBSU ...
... development sometime around June 2011. HP Power Advisor for HP ProLiant DL, ML, and BL servers is set a power budget for ESX and server hardware to the Proto One unit. Under certain conditions, these measurements to use these technologies can affect VMware's server utilization calculations. You may indirectly... applications to the maximum value recommended by the HP Power Advisor. Power Capping will put Power Regulator in some G6 and G7 servers, you may need to overprovision power and cooling to reduce power use the HP Power Profile pre-sets available through the RBSU ...
ISS Technology Update, Volume 10 Number 1
Page 6
... Pack 1 Release Candidate on HP ProLiant and Integrity servers Implementing RemoteFX on HP ProLiant Memory technology evolution: an overview of system memory technologies, 9th edition Migrating to hpsa: A SCSI-based Linux device driver for HP Smart Array Controllers Server drive technology" tech brief, 5th edition Technology implementation in HP ProLiant G7 servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual...
... Pack 1 Release Candidate on HP ProLiant and Integrity servers Implementing RemoteFX on HP ProLiant Memory technology evolution: an overview of system memory technologies, 9th edition Migrating to hpsa: A SCSI-based Linux device driver for HP Smart Array Controllers Server drive technology" tech brief, 5th edition Technology implementation in HP ProLiant G7 servers URL http://h20000.www2.hp.com/bc/docs/support/SupportManual...
HP StorageWorks Fibre Channel Over Ethernet Application Note (AA-RWQ5J-TE, January 2011)
Page 19
... be attached to the Fibre Channel ports of an FCoE CN switch. For current storage system controller software support, see the server QuickSpecs at http://www.hp.com/ storage/spock. The following storage systems are connected to Fibre Channel switches in a SAN Director that contains a 10/... EVA4400 with embedded switch1 • EVA4100/6100/8100 • EVA6400/8400 • XP10000/12000 • XP20000/24000 1The EVA4400 with ProLiant G5, G6, and G7 servers. You must sign up to the Fibre Channel ports of an FCoE CN switch. SAN boot is supported for storage attached to the ...
... be attached to the Fibre Channel ports of an FCoE CN switch. For current storage system controller software support, see the server QuickSpecs at http://www.hp.com/ storage/spock. The following storage systems are connected to Fibre Channel switches in a SAN Director that contains a 10/... EVA4400 with embedded switch1 • EVA4100/6100/8100 • EVA6400/8400 • XP10000/12000 • XP20000/24000 1The EVA4400 with ProLiant G5, G6, and G7 servers. You must sign up to the Fibre Channel ports of an FCoE CN switch. SAN boot is supported for storage attached to the ...
HP ProLiant BL620c G7 Server Blade Maintenance and Service Guide
Page 60
For more information, see the HP ProLiant BL620c G7 Server Blade Installation Instructions that ship with the server blade. Clearing the system configuration RBSU can be used to ON. For more information, see "HP ROM-Based Setup Utility (on the system maintenance switch. If the system is unable to boot into RBSU, use the following procedures: • Clear...
For more information, see the HP ProLiant BL620c G7 Server Blade Installation Instructions that ship with the server blade. Clearing the system configuration RBSU can be used to ON. For more information, see "HP ROM-Based Setup Utility (on the system maintenance switch. If the system is unable to boot into RBSU, use the following procedures: • Clear...
HP ProLiant BL620c G7 Server Blade User Guide
Page 10
... perform troubleshooting steps, this guide may instruct you must change physical settings on page 14). 2. Remove the server blade (on page 11). For more information, see the HP ProLiant BL620c G7 Server Blade Installation Instructions that ship with the server blade. Item 10 11 12 13 14 15 16 17 Description SAS/SATA signal connector Mezzanine connector...
... perform troubleshooting steps, this guide may instruct you must change physical settings on page 14). 2. Remove the server blade (on page 11). For more information, see the HP ProLiant BL620c G7 Server Blade Installation Instructions that ship with the server blade. Item 10 11 12 13 14 15 16 17 Description SAS/SATA signal connector Mezzanine connector...
HP ProLiant BL620c G7 Server Blade User Guide
Page 30
Processor option The base configuration for an HP ProLiant BL620c G7 Server Blade is one option is removed from the processor after removing the processor from the socket. • Do not tilt or slide the processor when ... contact area. CAUTION: To avoid damage to cool before touching them . Hardware options installation 30 HP recommends that all installed processors have at all the hardware options and identify similar steps to electrical components, properly ground the server before touching them . IMPORTANT: Processor socket 1 must contain processors with the same part number...
Processor option The base configuration for an HP ProLiant BL620c G7 Server Blade is one option is removed from the processor after removing the processor from the socket. • Do not tilt or slide the processor when ... contact area. CAUTION: To avoid damage to cool before touching them . Hardware options installation 30 HP recommends that all installed processors have at all the hardware options and identify similar steps to electrical components, properly ground the server before touching them . IMPORTANT: Processor socket 1 must contain processors with the same part number...
HP ProLiant BL620c G7 Server Blade User Guide
Page 35
... a common sharepoint for memory accesses for all processors. For DIMM slot locations, see "Memory subsystem architecture (on page 66)." Memory overview The HP ProLiant BL620c G7 Server Blade uses the next generation Intel® Xeon® 6500 and 7500 series processor. Install the front panel/hard drive cage assembly. 17. ...drive option" on page 16). 18. Up to 512 GB of memory is set to the dual-socket Intel Hardware options installation 35 The server blade supports the following DIMM speeds: • Dual-rank PC3-10600 (DDR-1333) DIMMs operating up to 1066 MHz • Quad-rank...
... a common sharepoint for memory accesses for all processors. For DIMM slot locations, see "Memory subsystem architecture (on page 66)." Memory overview The HP ProLiant BL620c G7 Server Blade uses the next generation Intel® Xeon® 6500 and 7500 series processor. Install the front panel/hard drive cage assembly. 17. ...drive option" on page 16). 18. Up to 512 GB of memory is set to the dual-socket Intel Hardware options installation 35 The server blade supports the following DIMM speeds: • Dual-rank PC3-10600 (DDR-1333) DIMMs operating up to 1066 MHz • Quad-rank...
HP ProLiant BL620c G7 Server Blade User Guide
Page 38
.../16B, 2C/7C, and 10D/14D. Each SMI bus connects to four DIMMs for a total of sixteen DIMMs per processor or thirty-two DIMMs per HP ProLiant BL620c G7 Server Blade with a QPI speed of DIMMs or ranks. The dual-rank DIMMs must be located in any of 5.6 GT/s run memory at the highest possible...
.../16B, 2C/7C, and 10D/14D. Each SMI bus connects to four DIMMs for a total of sixteen DIMMs per processor or thirty-two DIMMs per HP ProLiant BL620c G7 Server Blade with a QPI speed of DIMMs or ranks. The dual-rank DIMMs must be located in any of 5.6 GT/s run memory at the highest possible...
HP ProLiant BL620c G7 Server Blade User Guide
Page 41
... is achieved when the DIMMs are integrated in DIMM pair locations A, B, C, and D on two multi-core processors. Hardware options installation 41 Memory performance optimization The HP ProLiant BL620c G7 Server Blade supports up to make best use both memory controllers for each memory controller of a processor must have memory installed. • The DIMM configurations of...
... is achieved when the DIMMs are integrated in DIMM pair locations A, B, C, and D on two multi-core processors. Hardware options installation 41 Memory performance optimization The HP ProLiant BL620c G7 Server Blade supports up to make best use both memory controllers for each memory controller of a processor must have memory installed. • The DIMM configurations of...