ProLiant Essentials Foundation Pack Installation Guide
Page 1
... server is supported by pressing the F9 key when the system first boots. For additional information on the hardware installation and configuration poster. 1. Using the Management CD The Management CD provides the tools needed to prepare the server for HP ProLiant server products. HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development...
... server is supported by pressing the F9 key when the system first boots. For additional information on the hardware installation and configuration poster. 1. Using the Management CD The Management CD provides the tools needed to prepare the server for HP ProLiant server products. HP ProLiant Essentials Foundation Pack Installation Guide © Copyright 2002, 2008 Hewlett-Packard Development...
Implementing Microsoft Windows Server 2003 with Service Pack 1 on ProLiant servers integration note
Page 17
... • For additional usage information, refer to install the PSP from the list of the ProLiant Support Pack (PSP) for Microsoft Windows Server 2003, which is installed, configure the array through...as the secondary controller and install the OS to continue the boot process. Insert the Windows Server 2003 SP1 CD into the CD-ROM drive to be installed properly, all software components are ..., exit the utility to a SCSI controller. Once the OS is available at http://h18023.www1.hp.com/support/files/server/us/locate/3376.html. Install Version 7.30A (or later) of components....
... • For additional usage information, refer to install the PSP from the list of the ProLiant Support Pack (PSP) for Microsoft Windows Server 2003, which is installed, configure the array through...as the secondary controller and install the OS to continue the boot process. Insert the Windows Server 2003 SP1 CD into the CD-ROM drive to be installed properly, all software components are ..., exit the utility to a SCSI controller. Once the OS is available at http://h18023.www1.hp.com/support/files/server/us/locate/3376.html. Install Version 7.30A (or later) of components....
Integrating Microsoft Windows Server 2003 R2 on HP ProLiant servers
Page 11
... To perform a manual installation: 1. Part 1: Choose one of the available methods for installing Windows Server 2003 R2 CD-1 HP BladeSystem installation The ProLiant Essentials Rapid Deployment Pack is necessary for the server. 4. All blade enclosures ship with any of servers via a GUI...the platform-specific configuration listed in Table 8. Especially designed for Rapid Deployment Pack, visit www.hp.com/servers/rdp. If necessary, update the system ROMs as the boot controller in this step is a server deployment product that facilitates the installation, configuration, and...
... To perform a manual installation: 1. Part 1: Choose one of the available methods for installing Windows Server 2003 R2 CD-1 HP BladeSystem installation The ProLiant Essentials Rapid Deployment Pack is necessary for the server. 4. All blade enclosures ship with any of servers via a GUI...the platform-specific configuration listed in Table 8. Especially designed for Rapid Deployment Pack, visit www.hp.com/servers/rdp. If necessary, update the system ROMs as the boot controller in this step is a server deployment product that facilitates the installation, configuration, and...
Integrating Microsoft Windows Server 2003 R2 on HP ProLiant servers
Page 12
... the Control Panel from the list of the ProLiant Management Agents. h. Smart Array Controllers requiring additional... the Simple Network Management Protocol (SNMP), if you may set your array controller as the boot controller Serial controllers Parallel SCSI controllers Retired controllers Smart Array P600 Smart Array 6404 Integrated Smart ... you want to use the functionality of components. b. d. Click Details. Insert the Windows Server 2003 R2 CD into CD-ROM drive to a SCSI controller. a. Click OK and then Next. Select Management and Monitoring Tools from the...
... the Control Panel from the list of the ProLiant Management Agents. h. Smart Array Controllers requiring additional... the Simple Network Management Protocol (SNMP), if you may set your array controller as the boot controller Serial controllers Parallel SCSI controllers Retired controllers Smart Array P600 Smart Array 6404 Integrated Smart ... you want to use the functionality of components. b. d. Click Details. Insert the Windows Server 2003 R2 CD into CD-ROM drive to a SCSI controller. a. Click OK and then Next. Select Management and Monitoring Tools from the...
Integrating Microsoft Windows Server 2003 R2 on HP ProLiant servers
Page 16
... edition) by booting from occurring, upgrade the HP Insight Management Agents and System Management drivers to the following : • Use the SmartStart Assisted Installation. Solution To prevent high CPU utilization from the Microsoft base media CD-ROM, a pop-up message to the Windows Health driver becomes trapped in degraded system performance. HP ProLiant Advanced System...
... edition) by booting from occurring, upgrade the HP Insight Management Agents and System Management drivers to the following : • Use the SmartStart Assisted Installation. Solution To prevent high CPU utilization from the Microsoft base media CD-ROM, a pop-up message to the Windows Health driver becomes trapped in degraded system performance. HP ProLiant Advanced System...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 18
...NT Disk Administrator. When loading Disk Administrator you will be notified, if a drive does not have received a signature from the System boot partition, and print out the log that the utility generates. Armed with minimal disruption and downtime. Controllers that contain bridges will automatically... current system settings. • Run the System Configuration Utility, from Windows NT. • Verify you have the necessary Windows NT CDs and the Compaq Support Paq for Microsoft Windows NT 4.0 to the original configuration. Drive letters remain the same, but disk number assignment...
...NT Disk Administrator. When loading Disk Administrator you will be notified, if a drive does not have received a signature from the System boot partition, and print out the log that the utility generates. Armed with minimal disruption and downtime. Controllers that contain bridges will automatically... current system settings. • Run the System Configuration Utility, from Windows NT. • Verify you have the necessary Windows NT CDs and the Compaq Support Paq for Microsoft Windows NT 4.0 to the original configuration. Drive letters remain the same, but disk number assignment...
PCI Bus Numbering in a Microsoft Windows NT Environment
Page 36
...us/index.html. The Compaq PCI Hot Plug Utility is available on the Compaq SmartStart and Support Software CD and on Compaq servers. Doc ID 064A/0797 white paper. Compaq Array Configuration Utility The Compaq Array ... Utility configures SMART-2 Array and Smart Array controllers. It is available from the Compaq SmartStart and Support Software CD and on Compaq Servers in a special Compaq System Tools folder. Once installed, the utility appears as the...number assignment. You can be obtained from within the system boot partition as remote systems accessible over the network.
...us/index.html. The Compaq PCI Hot Plug Utility is available on the Compaq SmartStart and Support Software CD and on Compaq servers. Doc ID 064A/0797 white paper. Compaq Array Configuration Utility The Compaq Array ... Utility configures SMART-2 Array and Smart Array controllers. It is available from the Compaq SmartStart and Support Software CD and on Compaq Servers in a special Compaq System Tools folder. Once installed, the utility appears as the...number assignment. You can be obtained from within the system boot partition as remote systems accessible over the network.
SMART-2DH Array Controller Reference Guide
Page 30
... three ROMPaq selections: System ROMPaq Firmware Upgrade Diskette for Compaq ProLiant Servers, System ROMPaq Firmware Upgrade Diskette for Option ROMPaq), depending upon your server s Access to a server or workstation with a bootable CD-ROM drive. Creating Diskettes To create ROMPaq diskettes: 1. From...list and select one of the following items to create the ROMPaq diskette(s). NEED TO KNOW REQUIRED Boot the server from the Compaq SmartStart and Support Software CD. 2. Follow the instructions on the screen to create ROMPaq utility diskette(s): s Compaq SmartStart and Support...
... three ROMPaq selections: System ROMPaq Firmware Upgrade Diskette for Compaq ProLiant Servers, System ROMPaq Firmware Upgrade Diskette for Option ROMPaq), depending upon your server s Access to a server or workstation with a bootable CD-ROM drive. Creating Diskettes To create ROMPaq diskettes: 1. From...list and select one of the following items to create the ROMPaq diskette(s). NEED TO KNOW REQUIRED Boot the server from the Compaq SmartStart and Support Software CD. 2. Follow the instructions on the screen to create ROMPaq utility diskette(s): s Compaq SmartStart and Support...
SMART-2DH Array Controller Reference Guide
Page 35
... 295469-002 File Name: E-CH04.DOC Last Saved On: 2/27/98 11:28 AM COMPAQ CONFIDENTIAL - You may already have a version of the boot disk; The System Configuration Utility performs a wide range of configuration activities, including the following: s Configures PCI boards automatically s Provides switch and jumper settings...NEED TO KNOW REQUIRED however, you use the version of hardware should be run directly from the Compaq SmartStart and Support Software CD supplied with it is used to configure the hardware installed in or connected to know how each piece of the utility supplied on...
... 295469-002 File Name: E-CH04.DOC Last Saved On: 2/27/98 11:28 AM COMPAQ CONFIDENTIAL - You may already have a version of the boot disk; The System Configuration Utility performs a wide range of configuration activities, including the following: s Configures PCI boards automatically s Provides switch and jumper settings...NEED TO KNOW REQUIRED however, you use the version of hardware should be run directly from the Compaq SmartStart and Support Software CD supplied with it is used to configure the hardware installed in or connected to know how each piece of the utility supplied on...
SMART-2DH Array Controller Reference Guide
Page 36
... "System Configuration Diskettes," for instructions on the screen to a server or workstation with a bootable CD-ROM drive. Boot the computer from the Compaq SmartStart and Support Software CD. See the following items to create Compaq System Configuration Utility diskettes: s Compaq SmartStart and Support ...Software CD (supplied in which you can create diskettes of the latest version of ...
... "System Configuration Diskettes," for instructions on the screen to a server or workstation with a bootable CD-ROM drive. Boot the computer from the Compaq SmartStart and Support Software CD. See the following items to create Compaq System Configuration Utility diskettes: s Compaq SmartStart and Support ...Software CD (supplied in which you can create diskettes of the latest version of ...
SMART-2DH Array Controller Reference Guide
Page 37
...98 11:28 AM COMPAQ CONFIDENTIAL - The system loads configuration files for the first SMART-2DH Controller and edit each parameter according to resume booting. 5. 4-3 Running the System Configuration Utility To run the System Configuration Utility. 4. Among these will set the SMART2DH Controller(s) configuration parameters...Step 3: View or edit details. 10. Place the Compaq SmartStart and Support Software CD in the server floppy drive. 2. or Place the System Configuration Utility diskette 1 in the server CD-ROM drive. The View Or Edit Details screen is where you are using the ...
...98 11:28 AM COMPAQ CONFIDENTIAL - The system loads configuration files for the first SMART-2DH Controller and edit each parameter according to resume booting. 5. 4-3 Running the System Configuration Utility To run the System Configuration Utility. 4. Among these will set the SMART2DH Controller(s) configuration parameters...Step 3: View or edit details. 10. Place the Compaq SmartStart and Support Software CD in the server floppy drive. 2. or Place the System Configuration Utility diskette 1 in the server CD-ROM drive. The View Or Edit Details screen is where you are using the ...
SMART-2DH Array Controller Reference Guide
Page 41
Select Step 5: Save and Exit on the Save and Exit screen. 6. Remove the CD or System Configuration diskette and verify that the server will boot normally without POST errors. Review and edit the Controller Characteristics of all other SMART- 2DH Controllers shown in the View or Edit Details screen, as ...
Select Step 5: Save and Exit on the Save and Exit screen. 6. Remove the CD or System Configuration diskette and verify that the server will boot normally without POST errors. Review and edit the Controller Characteristics of all other SMART- 2DH Controllers shown in the View or Edit Details screen, as ...
SMART-2DH Array Controller Reference Guide
Page 44
... Partition If SmartStart has been run the Array Configuration Utility directly from the SmartStart and Support Software CD. 1. Navigate through the menus to access instructions on loading and using CPQONLIN.NLM. Boot the server from the menu, then select the Array Configuration Utility. 3. SMART-2DH Array Controller ... Utility program should already be installed on the NetWare Programs from diskettes made using the Diskette Builder feature in the CD drive and power up the server. Generate the NPFC diskettes using the Diskette Builder feature on the server. 2. NEED TO KNOW ...
... Partition If SmartStart has been run the Array Configuration Utility directly from the SmartStart and Support Software CD. 1. Navigate through the menus to access instructions on loading and using CPQONLIN.NLM. Boot the server from the menu, then select the Array Configuration Utility. 3. SMART-2DH Array Controller ... Utility program should already be installed on the NetWare Programs from diskettes made using the Diskette Builder feature in the CD drive and power up the server. Generate the NPFC diskettes using the Diskette Builder feature on the server. 2. NEED TO KNOW ...
SMART-2DH Array Controller Reference Guide
Page 71
... to create the Novell Support Software Diskettes (SSD) and can skip to four blank diskettes s Any server or workstation with a bootable CD-ROM drive Creating Novell SSD Diskettes Two NetWare/intraNetWare drivers for the SMART-2DH Array Controller- From the Compaq System Utilities screen, select ... in the SMART2DH Array Controller Option Kit) s Up to the section "Handling Disk Drive Failures." Boot the server from the Compaq SmartStart and Support Software CD. 2. NEED TO KNOW REQUIRED 6-3 Novell NetWare/intraNetWare Use the instructions in this section to install the driver for a new SMART...
... to create the Novell Support Software Diskettes (SSD) and can skip to four blank diskettes s Any server or workstation with a bootable CD-ROM drive Creating Novell SSD Diskettes Two NetWare/intraNetWare drivers for the SMART-2DH Array Controller- From the Compaq System Utilities screen, select ... in the SMART2DH Array Controller Option Kit) s Up to the section "Handling Disk Drive Failures." Boot the server from the Compaq SmartStart and Support Software CD. 2. NEED TO KNOW REQUIRED 6-3 Novell NetWare/intraNetWare Use the instructions in this section to install the driver for a new SMART...
SMART-2DH Array Controller Reference Guide
Page 76
...10 or later) or CPQARRAY.HAM driver loaded. 4. You must use this utility. Load CPQDAOPT.NLM from the NetWare/intraNetWare Installation CD-ROM (D:\NW410\BOOT or D:\INTRANETWARE.312\________\C; Start your NetWare/intraNetWare server. 2. Copy the CLIB.NLM and STREAMS.NLM files from Novell SSD Disk...the line represents eight underscores) to the server's DOS partition before you have followed the instructions for installing NetWare/intraNetWare from CD found in optimizing performance and can increase drive array performance by adjusting the size of the Hot Fix Redirection Area of a...
...10 or later) or CPQARRAY.HAM driver loaded. 4. You must use this utility. Load CPQDAOPT.NLM from the NetWare/intraNetWare Installation CD-ROM (D:\NW410\BOOT or D:\INTRANETWARE.312\________\C; Start your NetWare/intraNetWare server. 2. Copy the CLIB.NLM and STREAMS.NLM files from Novell SSD Disk...the line represents eight underscores) to the server's DOS partition before you have followed the instructions for installing NetWare/intraNetWare from CD found in optimizing performance and can increase drive array performance by adjusting the size of the Hot Fix Redirection Area of a...
SMART-2DH Array Controller Reference Guide
Page 90
... Windows NT. After that was supplied in which you will need to initially set up at least one array. Boot the server from the Compaq SmartStart and Support Software CD. To create the diskettes: 1. Creating the Windows NT SSD Diskettes The Windows NT driver for the SMART-2DH... Controller is located on the Compaq SmartStart and Support Software CD that , the utility can skip this section. Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: ...
... Windows NT. After that was supplied in which you will need to initially set up at least one array. Boot the server from the Compaq SmartStart and Support Software CD. To create the diskettes: 1. Creating the Windows NT SSD Diskettes The Windows NT driver for the SMART-2DH... Controller is located on the Compaq SmartStart and Support Software CD that , the utility can skip this section. Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: ...
SMART-2DH Array Controller Reference Guide
Page 101
...non-Compaq) are different. From the Diskette Builder screen, select Create Support Software Diskettes from the Compaq SmartStart and Support Software CD. 2. Follow the instructions on the screen to create and label the diskettes. Accessing the Information Driver installation procedures for SCO ... Compaq. Place the diskette labeled SCO Installation Notes for systems running SCO OpenServer 5 from Compaq: 1. NEED TO KNOW REQUIRED Boot the server from CD only. 4. From the Compaq System Utilities screen, select Create Support Software. 3. Scroll down the list and select: Compaq ...
...non-Compaq) are different. From the Diskette Builder screen, select Create Support Software Diskettes from the Compaq SmartStart and Support Software CD. 2. Follow the instructions on the screen to create and label the diskettes. Accessing the Information Driver installation procedures for SCO ... Compaq. Place the diskette labeled SCO Installation Notes for systems running SCO OpenServer 5 from Compaq: 1. NEED TO KNOW REQUIRED Boot the server from CD only. 4. From the Compaq System Utilities screen, select Create Support Software. 3. Scroll down the list and select: Compaq ...
SMART-2DH Array Controller Reference Guide
Page 105
...drive of the new SMART-2DH Controller. From the Diskette Builder screen, select Create Support Software Diskettes from the Compaq SmartStart and Support Software CD. 2. Place the diskette labeled Documentation Diskette in an existing UnixWare server. 6-37 1. Reboot the system. 3. Updating the Compaq Insight ...Manager you will need to update the Insight Agents for this file to manually update the agents. NEED TO KNOW REQUIRED Boot the server from CD only. 4. Follow the instructions in SmartStart 3.40 provide the same Insight Manager support as for the SMART Controller and include...
...drive of the new SMART-2DH Controller. From the Diskette Builder screen, select Create Support Software Diskettes from the Compaq SmartStart and Support Software CD. 2. Place the diskette labeled Documentation Diskette in an existing UnixWare server. 6-37 1. Reboot the system. 3. Updating the Compaq Insight ...Manager you will need to update the Insight Agents for this file to manually update the agents. NEED TO KNOW REQUIRED Boot the server from CD only. 4. Follow the instructions in SmartStart 3.40 provide the same Insight Manager support as for the SMART Controller and include...
SMART-2DH Array Controller Reference Guide
Page 107
...Compaq OS/2 2.x Support Software. 5. From the Diskette Builder screen , select Create Support Software Diskettes from the Compaq SmartStart and Support Software CD. 2. Creating an SSD Diskette The OS/2 driver for all Compaq equipment supported by OS/2. Materials Needed You will first need to create the... OS/2 SSD diskette. Boot the server from CD only. 4. If you use SmartStart to install OS/2 and drivers on a new server you can skip this diskette: 1. To ...
...Compaq OS/2 2.x Support Software. 5. From the Diskette Builder screen , select Create Support Software Diskettes from the Compaq SmartStart and Support Software CD. 2. Creating an SSD Diskette The OS/2 driver for all Compaq equipment supported by OS/2. Materials Needed You will first need to create the... OS/2 SSD diskette. Boot the server from CD only. 4. If you use SmartStart to install OS/2 and drivers on a new server you can skip this diskette: 1. To ...
SMART-2DH Array Controller Reference Guide
Page 116
These diskettes contain the latest drivers and supporting documentation for VINES 6.0 and 7.0. Boot the server from CD only. 4. From the Compaq System Utilities screen, select Create Support Software. 3. Materials Needed You will first need the following ... other information for VINES 6.0 and 7.0 diskettes. Creating the Peripheral Adapter Support Software Diskettes The Banyan VINES 6.x and 7.x driver with a bootable CD-ROM drive. To access the driver you are installing the SMART-2DH Controller. From the Diskette Builder screen, select Create Support Software Diskettes from...
These diskettes contain the latest drivers and supporting documentation for VINES 6.0 and 7.0. Boot the server from CD only. 4. From the Compaq System Utilities screen, select Create Support Software. 3. Materials Needed You will first need the following ... other information for VINES 6.0 and 7.0 diskettes. Creating the Peripheral Adapter Support Software Diskettes The Banyan VINES 6.x and 7.x driver with a bootable CD-ROM drive. To access the driver you are installing the SMART-2DH Controller. From the Diskette Builder screen, select Create Support Software Diskettes from...