HP ProLiant G6 Technology Overview
Page 1
... ProLiant G6 servers ...3 Intel® Xeon® processor 5500 series ...3 Intel QuickPath Technology...3 Integrated memory controller ...4 Three-level cache hierarchy...4 Intel Hyper-Threading Technology 4 Intel Turbo Boost Technology ...4 Dynamic Power Management ...4 DDR-3 memory technology ...4 Smart Array technology ...5 Smart Array controllers ...5 HP SAS Expander Card ...5 Thermal Logic technologies ...6 Dynamic Power Capping ...6 'Sea of Sensors' ...6 Common Slot Power Supplies...
... ProLiant G6 servers ...3 Intel® Xeon® processor 5500 series ...3 Intel QuickPath Technology...3 Integrated memory controller ...4 Three-level cache hierarchy...4 Intel Hyper-Threading Technology 4 Intel Turbo Boost Technology ...4 Dynamic Power Management ...4 DDR-3 memory technology ...4 Smart Array technology ...5 Smart Array controllers ...5 HP SAS Expander Card ...5 Thermal Logic technologies ...6 Dynamic Power Capping ...6 'Sea of Sensors' ...6 Common Slot Power Supplies...
HP ProLiant G6 Technology Overview
Page 2
... can help you squeeze every bit of productivity out of ProLiant G6 servers. Simplify setup and operations Every ProLiant G6 server includes the HP Onboard Administrator, which allow you to right-size the power supply for Linux include a complete set of lifecycle management tools that lets you reclaim power capacity hidden by moving your data center up to...
... can help you squeeze every bit of productivity out of ProLiant G6 servers. Simplify setup and operations Every ProLiant G6 server includes the HP Onboard Administrator, which allow you to right-size the power supply for Linux include a complete set of lifecycle management tools that lets you reclaim power capacity hidden by moving your data center up to...
HP ProLiant G6 Technology Overview
Page 6
... I/O and memory sockets. Thermal Logic technologies HP is extending Thermal Logic technologies-originally offered on the HP BladeSystem-to draw more ProLiant G6 servers. Thermal Logic technologies include Dynamic Power Capping, thermal sensors, and common slot power supplies. Using IPM, administrators can reduce power to limit processor power use and control overall system power use in the server workload or...
... I/O and memory sockets. Thermal Logic technologies HP is extending Thermal Logic technologies-originally offered on the HP BladeSystem-to draw more ProLiant G6 servers. Thermal Logic technologies include Dynamic Power Capping, thermal sensors, and common slot power supplies. Using IPM, administrators can reduce power to limit processor power use and control overall system power use in the server workload or...
HP ProLiant G6 Technology Overview
Page 7
... blades. This integrated suite provides productivity for each server. These power supplies provide up , template, and alternate host capabilities that simplify server management through a single installer and a simplified licensing mechanism. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered by multi-system scaling, thermal and power management, and direct-to manage multi-system Linux environments. Onboard...
... blades. This integrated suite provides productivity for each server. These power supplies provide up , template, and alternate host capabilities that simplify server management through a single installer and a simplified licensing mechanism. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered by multi-system scaling, thermal and power management, and direct-to manage multi-system Linux environments. Onboard...
ISS Technology Update Index
Page 3
...: Disabling AMD® processor cores in ProLiant 4 300 series G5 and G6 servers Quick tip: Efficient deployments-Sun Solaris 10 for 5 x86/x64 Systems Quick tips for powering off/on - ISS Technology Update Index of HP 6 Gb/s 6 SAS drives PUE and...technology and online "on HP BladeSystem 10 c7000 enclosures and their components Removing disabled servers from HP Systems Insight 8 Manager S Shut down servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused by natural phenomena 4 Spotlight: HP Microsoft Solutions Lab benefits ...
...: Disabling AMD® processor cores in ProLiant 4 300 series G5 and G6 servers Quick tip: Efficient deployments-Sun Solaris 10 for 5 x86/x64 Systems Quick tips for powering off/on - ISS Technology Update Index of HP 6 Gb/s 6 SAS drives PUE and...technology and online "on HP BladeSystem 10 c7000 enclosures and their components Removing disabled servers from HP Systems Insight 8 Manager S Shut down servers gracefully with the HP ProLiant ML360 5 uninterruptible power supply solution Soft memory errors caused by natural phenomena 4 Spotlight: HP Microsoft Solutions Lab benefits ...
ISS Technology Update, Volume 8, Number 3
Page 7
...quality issue. Impressed by their design decisions. Nevertheless, Wayne kept implementing workarounds to focus on other platform teams through HP iLO (Onboard Administrator) is highly regarded for example, one platform intentionally or unintentionally implements a circuit differently. He... power supplies, and unpopulated I/O and memory slots. 7 Wayne has distinguished himself because of customer feedback received from marketing, management, and direct customer visits. The Common Design effort creates a server schematic that is well protected by ProLiant G6 servers' power ...
...quality issue. Impressed by their design decisions. Nevertheless, Wayne kept implementing workarounds to focus on other platform teams through HP iLO (Onboard Administrator) is highly regarded for example, one platform intentionally or unintentionally implements a circuit differently. He... power supplies, and unpopulated I/O and memory slots. 7 Wayne has distinguished himself because of customer feedback received from marketing, management, and direct customer visits. The Common Design effort creates a server schematic that is well protected by ProLiant G6 servers' power ...
ISS Technology Update, Volume 9 Number 1
Page 1
.../SupportManual/c019488 92/c01948892.pdf HP Power Supply Technology http://techcomm.cca.hp.com/whitepapers/2009/TC091110TB.pdf HP ProLiant 100-series Intel-based G6 server technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091203TB.pdf HP Smart Array Controller technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091204TB.pdf Using HP ProLiant Network Teaming Software with Microsoft...
.../SupportManual/c019488 92/c01948892.pdf HP Power Supply Technology http://techcomm.cca.hp.com/whitepapers/2009/TC091110TB.pdf HP ProLiant 100-series Intel-based G6 server technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091203TB.pdf HP Smart Array Controller technology, 3rd edition http://techcomm.cca.hp.com/WhitePapers/2009/TC091204TB.pdf Using HP ProLiant Network Teaming Software with Microsoft...
Visualization and Acceleration in HP ProLiant servers
Page 6
... for HP ProLiant servers Table 1provides a summary of power to support these accelerator cards. Capability matrix for supplying additional power to cards using special cables. Included in this table are capable of supplying an additional 75 watts to 225 watts of the mechanical, I /O Support Power Support ... power cables required to the accelerator cards using auxiliary power connectors on the system motherboard that connect to support them in ProLiant G5 servers ProLiant Server DL160 G5 DL165 G5 DL385 G5 DL785 G5 PCIe x16 I /O and power support incorporated into G6 ProLiant ...
... for HP ProLiant servers Table 1provides a summary of power to support these accelerator cards. Capability matrix for supplying additional power to cards using special cables. Included in this table are capable of supplying an additional 75 watts to 225 watts of the mechanical, I /O Support Power Support ... power cables required to the accelerator cards using auxiliary power connectors on the system motherboard that connect to support them in ProLiant G5 servers ProLiant Server DL160 G5 DL165 G5 DL385 G5 DL785 G5 PCIe x16 I /O and power support incorporated into G6 ProLiant ...