Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Page 57
...agent has detected a change in CPQIDE.MIB Symptom: IDE Logical Drive Status Change. Storage agents 57 Log Message: ATA RAID logical drive number %6 on the "%5" in the status of %2. The variable cpqIdeAtaDiskStatus indicates the current disk drive status.... NT Event ID: 1187 (Hex)0x843504a3 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: ATA RAID Logical Drive Status Change. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeControllerModel • cpqIdeControllerSlot • cpqIdeLogicalDriveControllerIndex...
...agent has detected a change in CPQIDE.MIB Symptom: IDE Logical Drive Status Change. Storage agents 57 Log Message: ATA RAID logical drive number %6 on the "%5" in the status of %2. The variable cpqIdeAtaDiskStatus indicates the current disk drive status.... NT Event ID: 1187 (Hex)0x843504a3 (cpqstmsg.dll) Log Severity: Warning (2) Event Title: ATA RAID Logical Drive Status Change. Supporting SNMP Trap Data: • sysName • cpqHoTrapFlags • cpqIdeControllerModel • cpqIdeControllerSlot • cpqIdeLogicalDriveControllerIndex...
ProLiant Essentials Foundation Pack Installation Guide
Page 1
... without notice. Boot the SmartStart CD and click Getting Started, for Arrays) or the Adaptec RAID Configuration Utility as shown on HP ProLiant servers. Follow the on server configuration and OS installation. HP shall not be liable for HP ProLiant server products. IMPORTANT: The SmartStart CD is proactive in the express warranty statements accompanying such products...
... without notice. Boot the SmartStart CD and click Getting Started, for Arrays) or the Adaptec RAID Configuration Utility as shown on HP ProLiant servers. Follow the on server configuration and OS installation. HP shall not be liable for HP ProLiant server products. IMPORTANT: The SmartStart CD is proactive in the express warranty statements accompanying such products...
Error Prevention Guide
Page 5
... that can result from improper disconnection. Anticipate the utilization rate and distribute servers based on enterprise class servers, high availability features such as Hot-Pluggable RAID memory functionality and Hot-Plug PCI slots effectively minimize the amount of Insight Manager 7. • Be sure that you allow enough time to make the...
... that can result from improper disconnection. Anticipate the utilization rate and distribute servers based on enterprise class servers, high availability features such as Hot-Pluggable RAID memory functionality and Hot-Plug PCI slots effectively minimize the amount of Insight Manager 7. • Be sure that you allow enough time to make the...
HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 71
MP Management Pack NIC network interface controller PCI peripheral component interface RAID redundant array of inexpensive (or independent) disks SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SIM Systems Insight Manager SMH System Management Homepage SNMP Simple Network Management Protocol SP1 Service Pack 1 SQL structured query language UPS uninterruptible power system WMI Windows Management Instrumentation Acronyms and abbreviations 71
MP Management Pack NIC network interface controller PCI peripheral component interface RAID redundant array of inexpensive (or independent) disks SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SIM Systems Insight Manager SMH System Management Homepage SNMP Simple Network Management Protocol SP1 Service Pack 1 SQL structured query language UPS uninterruptible power system WMI Windows Management Instrumentation Acronyms and abbreviations 71
HP Insight Server Migration Software for ProLiant User Guide
Page 29
...agent-based console operating system running Linux Virtual machine destination on host with encrypted partitions (Software RAID is not supported) • Running any post-migration steps such as Linux Support Packs installation and HP SIM discovery SMP Boot CDs • SMP Physical Boot CD-This is used to boot the...Host Agent operating system running Windows Windows SMP VM Host Agent Virtual machine destination on agent-less host SMP Virtual Boot CD Using the HP SIM CMS to deploy SMP Agent You can use this CD to install SMP application or SMP Source Agent, or to boot physical ...
...agent-based console operating system running Linux Virtual machine destination on host with encrypted partitions (Software RAID is not supported) • Running any post-migration steps such as Linux Support Packs installation and HP SIM discovery SMP Boot CDs • SMP Physical Boot CD-This is used to boot the...Host Agent operating system running Windows Windows SMP VM Host Agent Virtual machine destination on agent-less host SMP Virtual Boot CD Using the HP SIM CMS to deploy SMP Agent You can use this CD to install SMP application or SMP Source Agent, or to boot physical ...
HP Insight Server Migration Software for ProLiant User Guide
Page 51
... the partitions do not need to a single contiguous partition. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to be migrated. Additional bootable partitions might be contained in the auto run window of the SMP application. 4. The operating system must... server, select the Deploy SMP Source Agent checkbox, enter the User name and Password, and then click Next. 5. 3. Volumes marked as active are migrated to -ProLiant (P2P) migrations for Windows 51
... the partitions do not need to a single contiguous partition. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to be migrated. Additional bootable partitions might be contained in the auto run window of the SMP application. 4. The operating system must... server, select the Deploy SMP Source Agent checkbox, enter the User name and Password, and then click Next. 5. 3. Volumes marked as active are migrated to -ProLiant (P2P) migrations for Windows 51
HP Insight Server Migration Software for ProLiant User Guide
Page 70
... boot partition is migrated to the target boot disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to partitions on the boot disk and loaded using NT Boot Loader (NTLDR). If only one active volume exists, by default it...
... boot partition is migrated to the target boot disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to partitions on the boot disk and loaded using NT Boot Loader (NTLDR). If only one active volume exists, by default it...
HP Insight Server Migration Software for ProLiant User Guide
Page 84
... active are migrated to partitions on a common destination disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to a single contiguous partition. You can only resize NTFS partitions. 84 Using SMP for server migration Volumes on the boot disk and...
... active are migrated to partitions on a common destination disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are migrated to a single contiguous partition. You can only resize NTFS partitions. 84 Using SMP for server migration Volumes on the boot disk and...
HP Insight Server Migration Software for ProLiant User Guide
Page 96
... might be migrated. CD to the target boot disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are selected by default. Volumes that the volume containing the active boot partition (which contains the boot.ini, NTLDR, and NTDETECT.com files) is...
... might be migrated. CD to the target boot disk. If multiple active volumes exist, ensure that span multiple dynamic disks (including spanned, striped, mirrored, and RAID 5 volumes) are selected by default. Volumes that the volume containing the active boot partition (which contains the boot.ini, NTLDR, and NTDETECT.com files) is...
HP Insight Server Migration Software for ProLiant User Guide
Page 104
... SP4) to a SAN disk on the source. Do not restart the server immediately. 4. Expand the SCSI and RAID controllers group. Click Properties. Proceed through HP SIM, but HP SIM is launched from SAN HBA driver. 5. After the driver update, restart the destination server. A local disk ...Windows 2003 to Server B migration, where A and B are distinct servers. SMP can be selected. After a successful migration, manually install the ProLiant Support Pack on the destination and some source disks migrated to a SAN disk on the same server. b. f. Download the latest Windows 2000 Boot...
... SP4) to a SAN disk on the source. Do not restart the server immediately. 4. Expand the SCSI and RAID controllers group. Click Properties. Proceed through HP SIM, but HP SIM is launched from SAN HBA driver. 5. After the driver update, restart the destination server. A local disk ...Windows 2003 to Server B migration, where A and B are distinct servers. SMP can be selected. After a successful migration, manually install the ProLiant Support Pack on the destination and some source disks migrated to a SAN disk on the same server. b. f. Download the latest Windows 2000 Boot...
HP Insight Server Migration Software for ProLiant User Guide
Page 132
... of Windows 2000 to a destination server with bad blocks. a. Expand the SCSI and RAID controllers group. Click Properties. 132 Troubleshooting To return to the original configuration, reboot the ...migration of disks with the Emulex LPe1105-HP 4Gb FC HBA might cause a blue screen on the destination server. After Windows boots, install the ProLiant Support Pack on the destination disk,... screen If your most recent settings that all antivirus and firewall software is a BL680c G5 or a BL685c G1 and you manually installed PSP without immediately installing the latest Emulex boot...
... of Windows 2000 to a destination server with bad blocks. a. Expand the SCSI and RAID controllers group. Click Properties. 132 Troubleshooting To return to the original configuration, reboot the ...migration of disks with the Emulex LPe1105-HP 4Gb FC HBA might cause a blue screen on the destination server. After Windows boots, install the ProLiant Support Pack on the destination disk,... screen If your most recent settings that all antivirus and firewall software is a BL680c G5 or a BL685c G1 and you manually installed PSP without immediately installing the latest Emulex boot...
Booting HP ProLiant servers from a storage area network
Page 2
... system performance and system stability. Supported firmware versions Outdated firmware is essential to eliminate serverbased internal boot devices. Now, certain HP ProLiant server, StorageWorks Fibre Channel host bus adapter (HBA), and RAID array combinations support external OS booting. Supported Fibre Channel switches The matrix at ftp://ftp.compaq.com/pub/products/servers/support...
... system performance and system stability. Supported firmware versions Outdated firmware is essential to eliminate serverbased internal boot devices. Now, certain HP ProLiant server, StorageWorks Fibre Channel host bus adapter (HBA), and RAID array combinations support external OS booting. Supported Fibre Channel switches The matrix at ftp://ftp.compaq.com/pub/products/servers/support...
Drive technology overview
Page 1
... technology ...7 Serial Attached SCSI (SAS) ...7 SAS-2 ...8 Second generation Serial ATA (SATA 8 Interconnect bandwidths and drive throughput 8 Improved performance and reliability with RAID 9 Advanced controllers ...9 Solid state drives for servers...9 HP solid state drive reliability requirements 10 NAND over provisioning and wear-levelling 10 Power loss protection ...10 Value, mainstream and performance SSDs...
... technology ...7 Serial Attached SCSI (SAS) ...7 SAS-2 ...8 Second generation Serial ATA (SATA 8 Interconnect bandwidths and drive throughput 8 Improved performance and reliability with RAID 9 Advanced controllers ...9 Solid state drives for servers...9 HP solid state drive reliability requirements 10 NAND over provisioning and wear-levelling 10 Power loss protection ...10 Value, mainstream and performance SSDs...
Drive technology overview
Page 9
...the additional SAS-2 bandwidth for increased overall performance. HP recommends always using SAS expanders that is better than the performance of multiple physical disks. block striping with RAID Drives do fail; fault tolerance RAID 6 - These controllers include both hardware and software... are available for SAS, SATA, and SCSI interfaces. no redundancy, performance improvement only RAID 1 - mirroring and striping; A single logical disk (as the HP Smart Array, decouple the logical disks seen by how they achieve data reliability (how parity or other...
...the additional SAS-2 bandwidth for increased overall performance. HP recommends always using SAS expanders that is better than the performance of multiple physical disks. block striping with RAID Drives do fail; fault tolerance RAID 6 - These controllers include both hardware and software... are available for SAS, SATA, and SCSI interfaces. no redundancy, performance improvement only RAID 1 - mirroring and striping; A single logical disk (as the HP Smart Array, decouple the logical disks seen by how they achieve data reliability (how parity or other...
HP ProLiant G6 Technology Overview
Page 5
First, the on-line ProLiant Memory Configuration Tool (www.hp.com/go/ddr3memoryconfigurator) will support 6Gb SAS when a firmware upgrade becomes available in an array without downtime or data loss • RAID 60 - Second, the DDR-3 Memory for JBODs (just a bunch of the drives. Smart Array technology Smart Array controllers The latest Smart Array...
First, the on-line ProLiant Memory Configuration Tool (www.hp.com/go/ddr3memoryconfigurator) will support 6Gb SAS when a firmware upgrade becomes available in an array without downtime or data loss • RAID 60 - Second, the DDR-3 Memory for JBODs (just a bunch of the drives. Smart Array technology Smart Array controllers The latest Smart Array...
HP ProLiant G6 Technology Overview
Page 7
...Full lifecycle management is an integrated solution to manage multi-system Linux environments. Consistently configure server boot order, network configuration, RAID settings, and other server parameters. These power supplies provide up , template, and alternate host capabilities that simplify server management...with your own internally developed deployment scripts or with HP Systems Insight Manager, RBSU, ORCA, and the embedded Baseboard Management Controller (BMC) to -hardware control. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered by iLO100 works hand-in ...
...Full lifecycle management is an integrated solution to manage multi-system Linux environments. Consistently configure server boot order, network configuration, RAID settings, and other server parameters. These power supplies provide up , template, and alternate host capabilities that simplify server management...with your own internally developed deployment scripts or with HP Systems Insight Manager, RBSU, ORCA, and the embedded Baseboard Management Controller (BMC) to -hardware control. On HP ProLiant 100 series G6 servers, ProLiant Onboard Administrator Powered by iLO100 works hand-in ...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 11
... drivers. Table 3. NOTE All storage option drivers have a digital signature. This package is available on the HP website: www.hp.com/go/ws2008. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal 4/8 Port SAS HBA LSI_SAS.SYS 9 99 9 9 Smart Array: E200 E200i E500...
... drivers. Table 3. NOTE All storage option drivers have a digital signature. This package is available on the HP website: www.hp.com/go/ws2008. HP has updated the ProLiant Support Pack 8.00 for Windows 2000/Server 2003 6-Port SATA RAID Controller AAC.SYS 9 99 9 9 9 9 Internal 4/8 Port SAS HBA LSI_SAS.SYS 9 99 9 9 Smart Array: E200 E200i E500...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 18
... a manual install of Windows Server 2008 is loaded and started . Update iLO 2 firmware to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Pre-installation tasks To prepare for installation, ensure that SNMP is loaded and the service is started . NOTE After ... Manager and agents, be required to Version 1.29 (or later). Use the steps below to configure the RAID settings for the server. Install the HP Insight Management Agents only after SNMP is supported through manual and assisted path installation options. Windows Server 2008 installation...
... a manual install of Windows Server 2008 is loaded and started . Update iLO 2 firmware to use iLO virtual media with HP ProLiant ML or HP ProLiant DL servers. 2. Pre-installation tasks To prepare for installation, ensure that SNMP is loaded and the service is started . NOTE After ... Manager and agents, be required to Version 1.29 (or later). Use the steps below to configure the RAID settings for the server. Install the HP Insight Management Agents only after SNMP is supported through manual and assisted path installation options. Windows Server 2008 installation...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 23
... A blue screen displaying a "BUGCODE_USB_DRIVER" error may display during Driver Injection on an HP Smart Array controller, these polices in device manager do not get loaded during installation of...not have any INF files that reference the lsicsb6 driver. 23 Description An LSI IDE RAID driver is injected, no workaround at this error occurs, download and install iLO 2 firmware... adapters or NICs. Appendix A: known issues and workarounds ProLiant servers with Windows Server 2008 Table A-1 lists the known issues with ProLiant servers with Windows Server 2008. Issue 3 A blue ...
... A blue screen displaying a "BUGCODE_USB_DRIVER" error may display during Driver Injection on an HP Smart Array controller, these polices in device manager do not get loaded during installation of...not have any INF files that reference the lsicsb6 driver. 23 Description An LSI IDE RAID driver is injected, no workaround at this error occurs, download and install iLO 2 firmware... adapters or NICs. Appendix A: known issues and workarounds ProLiant servers with Windows Server 2008 Table A-1 lists the known issues with ProLiant servers with Windows Server 2008. Issue 3 A blue ...
Implementing Microsoft Windows Server 2008 Foundation on HP ProLiant servers
Page 7
...administrators to configure the RAID settings for Microsoft Windows Server 2008 Foundation Version 8.25 is supported with Windows Server 2008 Foundation on the following ProLiant series servers: • ProLiant DL300 series servers • ProLiant ML300 series servers The HP ProLiant Easy Set-up CD... to update systems remotely • Reducing server maintenance costs • Saving time Supported components for ProLiant servers HP recommends using SmartStart 8.25 or later. The HP ProLiant Support Pack for the server. Update iLO 2 firmware to help efficiently install, upgrade,...
...administrators to configure the RAID settings for Microsoft Windows Server 2008 Foundation Version 8.25 is supported with Windows Server 2008 Foundation on the following ProLiant series servers: • ProLiant DL300 series servers • ProLiant ML300 series servers The HP ProLiant Easy Set-up CD... to update systems remotely • Reducing server maintenance costs • Saving time Supported components for ProLiant servers HP recommends using SmartStart 8.25 or later. The HP ProLiant Support Pack for the server. Update iLO 2 firmware to help efficiently install, upgrade,...