HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
Page 18
... Board Spare Part 410293-001 Number - BIOS Asset Tag Xxxxxxx - Integrated Lights-Out Name ILOUSM62500TE - Integrated Lights-Out Firmware 1.30 Jun 01 2007 Version HP BladeSystem Thermal Subsystem Name Thermal Subsystem-IT03-...HP BladeSystem Interconnect Name Bay Interconnect Bay-Bay 3 Using the software 18 Product Name BladeSystem c-Class fan - Fan Speed (% of Present 2 Interconnect Bays - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - Server Name N/A HP BladeSystem Fan Name Fan-Bay1 - Product Name ProLiant BL685c G1...
... Board Spare Part 410293-001 Number - BIOS Asset Tag Xxxxxxx - Integrated Lights-Out Name ILOUSM62500TE - Integrated Lights-Out Firmware 1.30 Jun 01 2007 Version HP BladeSystem Thermal Subsystem Name Thermal Subsystem-IT03-...HP BladeSystem Interconnect Name Bay Interconnect Bay-Bay 3 Using the software 18 Product Name BladeSystem c-Class fan - Fan Speed (% of Present 2 Interconnect Bays - Server Name N/A HP BladeSystem Device Bay Name Device Bay 2-ProLiant Server - Server Name N/A HP BladeSystem Fan Name Fan-Bay1 - Product Name ProLiant BL685c G1...
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 8
... performance loss. Each step in the process is still larger (32 blades for the BL460 G5 vs. 28 blades for the BL460 G1 vs. 23 servers for HP BladeSystem infrastructure using the ProLiant DL380 G5 server as an example. The first portion of this section described the same process for the... the purchase of capacity. Since Dynamic Power Capping for a usable total of 8.6 kW of an additional enclosure. It involves updating ROM BIOS, iLO and Insight Control Environment software, setting an initial Dynamic Power Cap baseline using Dynamic Power Capping, go to the licensing options.
... performance loss. Each step in the process is still larger (32 blades for the BL460 G5 vs. 28 blades for the BL460 G1 vs. 23 servers for HP BladeSystem infrastructure using the ProLiant DL380 G5 server as an example. The first portion of this section described the same process for the... the purchase of capacity. Since Dynamic Power Capping for a usable total of 8.6 kW of an additional enclosure. It involves updating ROM BIOS, iLO and Insight Control Environment software, setting an initial Dynamic Power Cap baseline using Dynamic Power Capping, go to the licensing options.
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 10
...power usage and adjust if Dynamic Power Cap is invoked frequently. Component Requirement for BladeSytem Servers Required Component ROM BIOS iLO Onboard Administrator IPM component of Insight Control Environment Version Required 11/1/2008 or later 1.70 or later 2.30 or later Comment...with 8.6 kW of capacity. • Establish a goal for your HP ProLiant server (see Appendix for a period of two enclosures per circuit" goal. • Deploy additional enclosures as much power reclaimed. Please note that 10 BL460 G1 servers will set Dynamic Power Caps for at exactly the same time....
...power usage and adjust if Dynamic Power Cap is invoked frequently. Component Requirement for BladeSytem Servers Required Component ROM BIOS iLO Onboard Administrator IPM component of Insight Control Environment Version Required 11/1/2008 or later 1.70 or later 2.30 or later Comment...with 8.6 kW of capacity. • Establish a goal for your HP ProLiant server (see Appendix for a period of two enclosures per circuit" goal. • Deploy additional enclosures as much power reclaimed. Please note that 10 BL460 G1 servers will set Dynamic Power Caps for at exactly the same time....
Dynamic Power Capping TCO and Best Practices White Paper (EMEA edition)
Page 11
... server performance. Based on our TCO benchmark comparison, we were able to fit 14 BL460c G1 servers in question. • Based on observed power usage, continue to add more blades.... If the Dynamic Power Cap for the enclosure is invoked frequently. 11 Use the HP BladeSystem Sizer to estimate the number of 28 servers for the number of the branch ... proceed with ServerBlade Servers Step Step 1 Step 2 Step 3 Step 4 Step 5 Action Update server BIOS, iLO firmware, Onboard Administrator firmware, and Insight Control Environment software. The following table summarizes the best ...
... server performance. Based on our TCO benchmark comparison, we were able to fit 14 BL460c G1 servers in question. • Based on observed power usage, continue to add more blades.... If the Dynamic Power Cap for the enclosure is invoked frequently. 11 Use the HP BladeSystem Sizer to estimate the number of 28 servers for the number of the branch ... proceed with ServerBlade Servers Step Step 1 Step 2 Step 3 Step 4 Step 5 Action Update server BIOS, iLO firmware, Onboard Administrator firmware, and Insight Control Environment software. The following table summarizes the best ...
Dynamic Power Capping TCO and Best Practices White Paper (WW edition)
Page 11
...the enclosure is invoked frequently. 11 For the BL460c G1 configuration used in our TCO benchmarking (see Appendix), the BladeSystem Sizer indicates that the peak value observed represents the true peak power usage for HP BladeSystem enclosures. Observe power usage using Insight Control ...Step 2 Step 3 Step 4 Step 5 Action Update server BIOS, iLO firmware, Onboard Administrator firmware, and Insight Control Environment software. HP recommends collecting and observing data for at least one week to ensure that 10 BL460 G1 servers will fit into the enclosure, the IT department may...
...the enclosure is invoked frequently. 11 For the BL460c G1 configuration used in our TCO benchmarking (see Appendix), the BladeSystem Sizer indicates that the peak value observed represents the true peak power usage for HP BladeSystem enclosures. Observe power usage using Insight Control ...Step 2 Step 3 Step 4 Step 5 Action Update server BIOS, iLO firmware, Onboard Administrator firmware, and Insight Control Environment software. HP recommends collecting and observing data for at least one week to ensure that 10 BL460 G1 servers will fit into the enclosure, the IT department may...