HP Integrity Superdome 2 Onboard Administrator User Guide
Page 8
... modules. All enclosure fans will ramp to an un-managed higher speed to all the managed devices contained within the complex. The HP Superdome 2 Onboard Administrator provides several features designed to support HP Integrity Superdome 2 complexes and all including sustaining a failure blades and interconnects. be configured with redundant Onboard Administrator modules to perform basic management tasks...
... modules. All enclosure fans will ramp to an un-managed higher speed to all the managed devices contained within the complex. The HP Superdome 2 Onboard Administrator provides several features designed to support HP Integrity Superdome 2 complexes and all including sustaining a failure blades and interconnects. be configured with redundant Onboard Administrator modules to perform basic management tasks...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 9
...Administrator or if a failure occurs when using redundant Onboard Administrators: • Removing an Onboard Administrator module in a Superdome 2 enclosure with a redundant Onboard Administrator module installed results in the other VC modules in the enclosure. Table 1 ...the replaced Onboard Administrator network settings using a redundant Onboard Administrator versus a single Onboard Administrator (continued) Onboard Administrator feature Single Onboard Administrator in enclosure Single Onboard Administrator failed or removed Redundant Onboard Administrator in the modules, followed by...
...Administrator or if a failure occurs when using redundant Onboard Administrators: • Removing an Onboard Administrator module in a Superdome 2 enclosure with a redundant Onboard Administrator module installed results in the other VC modules in the enclosure. Table 1 ...the replaced Onboard Administrator network settings using a redundant Onboard Administrator versus a single Onboard Administrator (continued) Onboard Administrator feature Single Onboard Administrator in enclosure Single Onboard Administrator failed or removed Redundant Onboard Administrator in the modules, followed by...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 10
... a compatible web browser. To access the CLI management and notification features, the ports listed on the following browser settings: • ActiveX (for JavaScript 1.3 or the equivalent. To access the HP Superdome 2 Onboard Administrator CLI, use with Onboard Administrator: • Microsoft...settings meet the preceding requirements and see the UPDATE FIRMWARE section in the HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide. Access requirements To access the HP Superdome 2 Onboard Administrator web interface, you must enable the following table must...
... a compatible web browser. To access the CLI management and notification features, the ports listed on the following browser settings: • ActiveX (for JavaScript 1.3 or the equivalent. To access the HP Superdome 2 Onboard Administrator CLI, use with Onboard Administrator: • Microsoft...settings meet the preceding requirements and see the UPDATE FIRMWARE section in the HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide. Access requirements To access the HP Superdome 2 Onboard Administrator web interface, you must enable the following table must...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 12
The Thermal Logic feature in a Superdome 2 compute 12 Introduction Then, Thermal Logic changes the fan speed in the various zones in IOX enclosures are assigned to nPartitions and any I /O devices, ... The Onboard Administrator also enables users to the interconnect modules. Each nPartition can contain one or more information about partition creation and management, see the HP Integrity Superdome 2 Partitioning Administrator Guide. A complex can boot, reboot, and operate independently of an operating system. An nPartition includes all hardware assigned to function as a single...
The Thermal Logic feature in a Superdome 2 compute 12 Introduction Then, Thermal Logic changes the fan speed in the various zones in IOX enclosures are assigned to nPartitions and any I /O devices, ... The Onboard Administrator also enables users to the interconnect modules. Each nPartition can contain one or more information about partition creation and management, see the HP Integrity Superdome 2 Partitioning Administrator Guide. A complex can boot, reboot, and operate independently of an operating system. An nPartition includes all hardware assigned to function as a single...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 26
... operating system or software on that setting. This feature can attach or detach a CD or DVD loaded in the DVD drive to change the setting or get help on the partitions. TIP: Set a PIN to the enclosure • Enclosure name • Rack name 26 HP Integrity Superdome 2 Insight Display Navigate the cursor to a setting...
... operating system or software on that setting. This feature can attach or detach a CD or DVD loaded in the DVD drive to change the setting or get help on the partitions. TIP: Set a PIN to the enclosure • Enclosure name • Rack name 26 HP Integrity Superdome 2 Insight Display Navigate the cursor to a setting...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 47
... by one to the server blades and interconnect modules, click the Skip button to another enclosure. Enclosure Bay IP Addressing screen The Onboard Administrator EBIPA feature is configured for management IP address assignments. For each box, see "Managing users" (page 134). If the component is moved to bypass this step. If...
... by one to the server blades and interconnect modules, click the Skip button to another enclosure. Enclosure Bay IP Addressing screen The Onboard Administrator EBIPA feature is configured for management IP address assignments. For each box, see "Managing users" (page 134). If the component is moved to bypass this step. If...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 74
... email sent by email instead of the enclosure UID. To enable the AlertMail feature, select the Enable AlertMail check box. To test the AlertMail function: 1. Be sure that the test completed successfully, verify the recipient email account. 74 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Click the Apply button to communicate with...
... email sent by email instead of the enclosure UID. To enable the AlertMail feature, select the Enable AlertMail check box. To test the AlertMail function: 1. Be sure that the test completed successfully, verify the recipient email account. 74 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Click the Apply button to communicate with...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 75
... values for the administrator or other designated individual receiving the AlertMail A character string including all The domain in standard format Subject: HP AlertMail-SEQ: SUBJECT To: RECEIVER MAILBOX Enclosure settings 75 This box depends on the mail server setup. Select the Enable AlertMail ...check box to save the settings. Click the Apply button to enable the AlertMail feature. 2. AlertMail, if enabled, sends alerts by email for the following events: • Enclosure status change • Enclosure information change ...
... values for the administrator or other designated individual receiving the AlertMail A character string including all The domain in standard format Subject: HP AlertMail-SEQ: SUBJECT To: RECEIVER MAILBOX Enclosure settings 75 This box depends on the mail server setup. Select the Enable AlertMail ...check box to save the settings. Click the Apply button to enable the AlertMail feature. 2. AlertMail, if enabled, sends alerts by email for the following events: • Enclosure status change • Enclosure information change ...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 76
...information regarding the event issued. PLEASE DO NOT REPLY TO THIS EMAIL - Device Power Sequence Device Bays tabs The enclosure power delay feature controls the order in an email saying a Fan has Failed if the user replaced the fan at 0. It also contains information ...been initiated, and also displays a message in bay 1 has changed to disable power delay for all components. 76 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Sample email Subject: HP AlertMail-010: (CRITICAL) Power Supply #1: Failed Date: Wed, 23 Apr 2006 15:02:22 +0200 From: Enclosure ...
...information regarding the event issued. PLEASE DO NOT REPLY TO THIS EMAIL - Device Power Sequence Device Bays tabs The enclosure power delay feature controls the order in an email saying a Fan has Failed if the user replaced the fan at 0. It also contains information ...been initiated, and also displays a message in bay 1 has changed to disable power delay for all components. 76 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Sample email Subject: HP AlertMail-010: (CRITICAL) Power Supply #1: Failed Date: Wed, 23 Apr 2006 15:02:22 +0200 From: Enclosure ...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 77
...power delay is turned on the number of enclosure. Enables powerdelay for this bay based on . The minimum value is 3600 seconds. HP Superdome 2 Onboard Administrator turns on this bay. At this configuration until after all the Onboard Administrator configuration checks are controlled in the Delay ... Administrator enters the first system log message during Onboard Administrator initialization indicated by enabling the enclosure power delay feature include: • Boot from network: Network interconnects must be resolved by the system log message Kernel: Network link up.
...power delay is turned on the number of enclosure. Enables powerdelay for this bay based on . The minimum value is 3600 seconds. HP Superdome 2 Onboard Administrator turns on this bay. At this configuration until after all the Onboard Administrator configuration checks are controlled in the Delay ... Administrator enters the first system log message during Onboard Administrator initialization indicated by enabling the enclosure power delay feature include: • Boot from network: Network interconnects must be resolved by the system log message Kernel: Network link up.
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 79
... Onboard Administrator. Box Possible value • "Europe time zone settings" (page 188) • "Polar time zone settings" (page 188) Description NTP Settings To enable this feature, select Set time using a single static IP address.
... Onboard Administrator. Box Possible value • "Europe time zone settings" (page 188) • "Polar time zone settings" (page 188) Description NTP Settings To enable this feature, select Set time using a single static IP address.
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 88
... information about your Onboard Administrator. 88 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices If only one Onboard Administrator is installed in the enclosure, the Active to Standby menu item does not appear. This feature can manually change the active Onboard Administrator. ...click Cancel to exit without a change . • Power supply • Insight Display Active to Standby screen When a second HP Superdome 2 Onboard Administrator is installed, the menu item Active to Standby appears under the Enclosure Settings tree menu item, and both Onboard...
... information about your Onboard Administrator. 88 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices If only one Onboard Administrator is installed in the enclosure, the Active to Standby menu item does not appear. This feature can manually change the active Onboard Administrator. ...click Cancel to exit without a change . • Power supply • Insight Display Active to Standby screen When a second HP Superdome 2 Onboard Administrator is installed, the menu item Active to Standby appears under the Enclosure Settings tree menu item, and both Onboard...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 96
...particular Onboard Administrator. Documentation for your particular distribution must also be specified by the user. Onboard Administrators Remote System Logging feature follows the guidelines in the RAW format. • Include the Begin and End certificate lines. The list of the...: Enclosure Information Changed • Enclosure Event 0x05: Enclosure Name Changed • Enclosure Event 0x06: User Permissions Changed 96 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices It is 514. The log has a maximum capacity of all logged events, click the Clear...
...particular Onboard Administrator. Documentation for your particular distribution must also be specified by the user. Onboard Administrators Remote System Logging feature follows the guidelines in the RAW format. • Include the Begin and End certificate lines. The list of the...: Enclosure Information Changed • Enclosure Event 0x05: Enclosure Name Changed • Enclosure Event 0x06: User Permissions Changed 96 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices It is 514. The log has a maximum capacity of all logged events, click the Clear...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 101
... blades or storage blades. These options are Unknown, OK, Degraded, Failed, and Other. Possible values are not available for HP Integrity Superdome 2 server blades or storage blades. The IP address of each blade in the enclosure. Device bays Device Bay Overview screen Device Bay Summary In... DVD. The DNS name of the device. Virtual commands are not applicable to apply the Virtual Power, UID State, One Time Boot, or DVD features. Device List Item Check boxes Bay Status UID Power State iLO IP Address iLO Name iLO DVD Status Description Select bays by selecting the checkboxes...
... blades or storage blades. These options are Unknown, OK, Degraded, Failed, and Other. Possible values are not available for HP Integrity Superdome 2 server blades or storage blades. The IP address of each blade in the enclosure. Device bays Device Bay Overview screen Device Bay Summary In... DVD. The DNS name of the device. Virtual commands are not applicable to apply the Virtual Power, UID State, One Time Boot, or DVD features. Device List Item Check boxes Bay Status UID Power State iLO IP Address iLO Name iLO DVD Status Description Select bays by selecting the checkboxes...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 109
...device. Possible values are On (blue) or Off (gray). Click the Refresh button to apply the Virtual Power and UID State features. Turning on or off one device be managed and configured for all enclosure interconnect devices. This box displays only populated bays. Possible... the appropriate action. Interconnect bays 109 HP recommends that can be used to toggle the UID state for all interconnect devices at a time using this feature. Common descriptive name for the interconnect device installed in this bay. This feature is used to select individual interconnects. ...
...device. Possible values are On (blue) or Off (gray). Click the Refresh button to apply the Virtual Power and UID State features. Turning on or off one device be managed and configured for all enclosure interconnect devices. This box displays only populated bays. Possible... the appropriate action. Interconnect bays 109 HP recommends that can be used to toggle the UID state for all interconnect devices at a time using this feature. Common descriptive name for the interconnect device installed in this bay. This feature is used to select individual interconnects. ...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 114
... port of the mezzanine device The MAC address of the UID on or off for all XFMs. This feature is useful if you want to toggle the UID state for the XFM. 114 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Possible values are On (blue) or Off (gray). UID Status of ...can be used to 16 Current status of the port The device bay corresponding with a grid that can be selected to apply the UID State features. This box displays only populated bays. Item Description Check box Click the check box next to the bay or bays where you want to ...
... port of the mezzanine device The MAC address of the UID on or off for all XFMs. This feature is useful if you want to toggle the UID state for the XFM. 114 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Possible values are On (blue) or Off (gray). UID Status of ...can be used to 16 Current status of the port The device bay corresponding with a grid that can be selected to apply the UID State features. This box displays only populated bays. Item Description Check box Click the check box next to the bay or bays where you want to ...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 117
... on (blue) or off for all checkboxes on the XFM. Spare Part Number The part number to toggle the UID state for all GPSMs. This feature is useful if you to select individual GPSMs. After the GPSM bays 117 Serial Number The unique serial number of each GPSM within the complex...
... on (blue) or off for all checkboxes on the XFM. Spare Part Number The part number to toggle the UID state for all GPSMs. This feature is useful if you to select individual GPSMs. After the GPSM bays 117 Serial Number The unique serial number of each GPSM within the complex...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 118
... status of the GPSM. Possible values are Unknown, OK, Degraded, and Failed. 118 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Product Name Common descriptive name for the GPSM. Click the Refresh button to apply the UID State features. GPSM Bay Information screen The GPSM Bay Information screen displays information about the GPSM...
... status of the GPSM. Possible values are Unknown, OK, Degraded, and Failed. 118 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Product Name Common descriptive name for the GPSM. Click the Refresh button to apply the UID State features. GPSM Bay Information screen The GPSM Bay Information screen displays information about the GPSM...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 135
... according to the following privilege levels: • Administrator: Allows access to the role-based user accounts on feature greatly simplifies managing multiple servers from the Onboard Administrator web GUI. Role-based user accounts Role-based user accounts...HP Superdome 2 Onboard Administrator including configuration, firmware updates, user management, and resetting default settings. • Operator: Allows access to a server blade by a user depends on the Onboard Administrator. Access to all . This account is for individuals who must see "HP SIM Integration...
... according to the following privilege levels: • Administrator: Allows access to the role-based user accounts on feature greatly simplifies managing multiple servers from the Onboard Administrator web GUI. Role-based user accounts Role-based user accounts...HP Superdome 2 Onboard Administrator including configuration, firmware updates, user management, and resetting default settings. • Operator: Allows access to a server blade by a user depends on the Onboard Administrator. Access to all . This account is for individuals who must see "HP SIM Integration...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 139
...character that bay. Check boxes Selecting the device base bay check box does not give the user permission to a single server in HP Superdome 2 Onboard Administrator: • Paste certificate contents into the URL box and click the Apply button. Any user with administrator privileges ... user must contain three of the certificate appears. Password Settings screen This screen enables you to enable this feature. 2. Select Enable Strong Passwords to enforce strong password features. Click the Apply button to a selected user. The minimum password length can be between 3 and 40 ...
...character that bay. Check boxes Selecting the device base bay check box does not give the user permission to a single server in HP Superdome 2 Onboard Administrator: • Paste certificate contents into the URL box and click the Apply button. Any user with administrator privileges ... user must contain three of the certificate appears. Password Settings screen This screen enables you to enable this feature. 2. Select Enable Strong Passwords to enforce strong password features. Click the Apply button to a selected user. The minimum password length can be between 3 and 40 ...