HP Integrity Superdome SX1000 Support and Manuals

Get Help and Manuals for this Hewlett-Packard item

View All Support Options Below
Free HP Integrity Superdome SX1000 manuals!
Problems with HP Integrity Superdome SX1000?

Ask a Question

Popular HP Integrity Superdome SX1000 Manual Pages

Ethernet Card (PCIe) Installation Guide for HP Integrity Servers - Page 6

... section at : http://support.hp.com To manually configure the adapter, follow these steps to enable access to install the adapter driver. Click Start→Programs→Administrative Tools→Computer Management. 6 Select one of the HP Integrity servers that describes the server operating system. Download the driver to the server or to HP Integrity Servers. If the Programs menu...
HP Version Control Agent Installation Guide - Page 32

... a repository to occur. 5. The VCRM Setup - Configuring Automatic Update The Automatic Update dialog box enables you do not want to automatically download ProLiant and Integrity Support Packs and components at a specific time. 2. In the Port field, enter the proxy server port. d. In the Password field, enter a valid password for your settings or Cancel to schedule automatic...
SmartSetup Scripting Toolkit Deployment Guide: HP Integrity Servers with Linux - Page 3

... SSTK Deployment Workflow 21 Setting Up a Model Server...21 Creating a Server Profile...21 Setting Up the Toolkit Environment...22 Launching the Server Replication...22 Capturing and Deploying System Images 22 Capturing Images...23 Image Format and Compatibility 23 Original HDD size X Cloned HDD size 23 Deploying Images...23 Upgrading RHEL Installations...23 SAN Environment Autoconfiguration...
SmartSetup Scripting Toolkit Deployment Guide: HP Integrity Servers with Linux - Page 13

..., you can set up a model server manually and then clone this setup on the model server. To produce a thousand CDs, for example, a CD manufacturer first creates a master CD and then copies it using SSTK involve four main stages: First, you set specific Extensible Firmware Interface (EFI) boot variables, create disk partitions, and tie into standard, unattended installation processes for...
SmartSetup Scripting Toolkit Deployment Guide: HP Integrity Servers with Linux - Page 21

..., the I/O configuration, the OS and drivers, and installed applications. For more information, see HP Integrity Essentials Foundation Pack for Linux User's Guide at the following topics: • "Setting Up a Model Server" (page 21) • "Creating a Server Profile" (page 21) • "Setting Up the Toolkit Environment" (page 22) • "Launching the Server Replication" (page 22) •...
Windows Integrity Management Agents Reference - Page 14

... in HPIFPTRAP.MIB. 5055 Error Cell halt Probable Cause: Internal Error Recommended Action: contact your HP representative for support. Replace CPU if problem persists, system will determine the user action. Recommended Action: Reboot, if problem persists contact your HP representative for support. SFW will not send any events to troubleshoot the problem. Recommended Action: Reboot, if...
Windows Integrity Management Agents Reference - Page 23

... the local rendezvous set Probable Cause: Fabric problem, Connection problem or timing problem. SNMP Trap: hpevtIoPciBusMixedSpeeds - 5419 in HPIFPTRAP.MIB. 5419 Warning Error: PCI Buses are installed. Platform Agent Events 23 SNMP Trap: hpevtFabricPortError - 5404 in HPIFPTRAP.MIB. 5406 Warning Error writing to find a needed service provider. SNMP Trap: hpevtFabricReadError...
Windows Integrity Management Agents Reference - Page 31

... to troubleshoot the problem. If problem persists contact your HP representative for ESI Table incorrect. Recommended Action: Upgrade system firmware. SNMP Trap: hpevtEfiHalt - 5708 in HPIFPTRAP.MIB. 5711 Warning chipspare not supported on quad Probable Cause: User installed a x8 DIMM in a system configured for support. Recommended Action: If user requires Chipspare, replace the...
Windows Integrity Management Agents Reference - Page 32

... - 5724 in HPIFPTRAP.MIB. 5729 Error Error creating the pdh ioconfig node or attaching the service to be a symptom of code Probable Cause: Reached unimplemented firmware. If problem persists, contact HP support to boot. Recommended Action: Reboot system.Upgrade system firmware. Invalidate NVM and retry to troubleshoot the problem. SNMP Trap: hpevtFpgaNodeInitError - 5728 in...
Windows Integrity Management Agents Reference - Page 33

... than a slave processor installed in the system. Event ID Event Severity Event Description 5730 Error Error encountered setting up the dillon_pdh node or service. Probable Cause: This is memory available. SNMP Trap: hpevtBootMonSelSteppingsNoEqual - 5738 in HPIFPTRAP.MIB. 5741 Warning cpu access error on a node. If problem persists, contact HP support. SNMP Trap: hpevtBootCpuOverClocked...
Windows Integrity Management Agents Reference - Page 47

... the voltage margin setting of CLU firmware. Recommended Action: Upgrade PDHC firmware to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. There should be other clues in HPIFPTRAP.MIB. 8135 Warning An attempt to write to read from a device on the PDHC's SM bus has failed. Contact HP Support personnel to troubleshoot the problem. SNMP Trap...
Windows Integrity Management Agents Reference - Page 51

....MIB. 8264 Warning Partition attempted to the firmware team. Recommended Action: Attempt the OLA operation again, or collect IPMI event logs and contact HP Customer Support for assistance. Contact HP Customer Support for assistance. Recommended Action: Contact HP support. This cannot be worked around in HPIFPTRAP.MIB. 8646 Error Attempt to update the PD PDT with OLA Cell failed...
Windows Integrity Management Agents Reference - Page 61

...: Troubleshoot the fabric and replace backplane or cells. Gather event logs and contact HP Customer Support for assistance. SNMP Trap: hpevtBootMoveCellMonarchsCheckSlaveErr 9373 in HPIFPTRAP.MIB. 9389 Error PDH space not available after release from reset. If problem persists contact your HP representative for support. If problem persists contact your HP representative for support...
Windows Integrity Overview - Page 12

... Setup CD: • Overview (this manual) • Release Notes • Installation Guide for Windows Server 2003 • Installation Guide for Windows Server 2008 and the HP SMH online help . Troubleshooting problems If you might encounter while installing the Integrity Support Pack or management agents. For additional information about HP SMH, see the HP Smart Update Manager (HPSUM) User...
HP Insight Manager WBEM Provider Events Reference - Page 57

... Action: Check XBC, Backplane, Flex Cables, Contact HP Support Personnel for a single cell model. Probable Cause: Fabric Access problem. WBEM ProviderName: FPL_IndicationProvider 8936 Warning Unexpected fabric firmware error. WBEM ProviderName: FPL_IndicationProvider 8940 Error Cell has been disabled by PDHC FW because the CPU modules are installed. Probable Cause: No CPU modules are not...

HP Integrity Superdome SX1000 Reviews

Do you have an experience with the HP Integrity Superdome SX1000 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.

Popular HP Integrity Superdome SX1000 Search Terms

The following terms are frequently used to search for HP Integrity Superdome SX1000 support:

Ask a New Question
Use the box below to post a new question about HP Integrity Superdome SX1000.
Manuals / Documents
Download any of our HP Integrity Superdome SX1000 manuals for free!

We have the following 26 documents available for the HP Integrity Superdome SX1000:
  • HP Insight Management WBEM Providers on Integrity Servers Data Sheet
  • User Guide, Sixth Edition - HP Integrity Superdome; HP9000 Superdome
  • Windows Integrity Management Agents Reference
  • Installation (Smart Setup) Guide, Windows Server 2008, v6.1
  • HP Insight Manager WBEM Provider Events Reference
  • Site Preparation Guide, Fifth Edition - HP Integrity Superdome and HP 9000 Superdome
  • Internal Cabling Guide for HP Smart Array Controllers
  • SmartSetup Scripting Toolkit Deployment Guide: HP Integrity Servers with Linux
  • HP Version Control Agent Installation Guide
  • HP Insight Management WBEM Providers on Integrity Servers User's Guide
  • HP Management Base Installation and User's Guide for Linux
  • 16 More!

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP Integrity Superdome SX1000 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP Integrity Superdome SX1000 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.