HP Integrity Superdome 2 WEEE Disassembly Instructions
Page 3
... for the products listed. Item Description Notes Qty. Marketing Name/Model CB900s i2 Superdome 2 compute enclosure Superdome 2 IOX Description Two socket server blade Eight slot blade enclosure Twelve PCIe slot I/O expansion enclosure Items Requiring Selective Treatment Items ...intended for use by end-of the following table lists the classified items requiring selective treatment for the HP Integrity Superdome 2 CB900s i2 server blade. HP Integrity Superdome 2 CB900s i2 The following tables. Up to remove components and materials requiring selective treatment. Mercury containing ...
... for the products listed. Item Description Notes Qty. Marketing Name/Model CB900s i2 Superdome 2 compute enclosure Superdome 2 IOX Description Two socket server blade Eight slot blade enclosure Twelve PCIe slot I/O expansion enclosure Items Requiring Selective Treatment Items ...intended for use by end-of the following table lists the classified items requiring selective treatment for the HP Integrity Superdome 2 CB900s i2 server blade. HP Integrity Superdome 2 CB900s i2 The following tables. Up to remove components and materials requiring selective treatment. Mercury containing ...
HP-UX Errata for HP Integrity Superdome 2
Page 3
....1009.01 • Diagnostic and Support Tools - Then, download and install the additional HP-UX components for HP Integrity Superdome 2 3 HP-UX Errata for your server: • https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=Super- The new HP Superdome 2 blades cannot be supported on Superdome 2) • PHKL_41301: 11.31 PCI cumulative patch (handles new IO errors for...
....1009.01 • Diagnostic and Support Tools - Then, download and install the additional HP-UX components for HP Integrity Superdome 2 3 HP-UX Errata for your server: • https://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=Super- The new HP Superdome 2 blades cannot be supported on Superdome 2) • PHKL_41301: 11.31 PCI cumulative patch (handles new IO errors for...
HP Integrity Superdome 2 Site Preparation Guide (AH337-9006A, August 2010)
Page 3
Table of Contents 1 HP Integrity Superdome 2 system overview 5 Complex components...5 Power subsystem...5 Cooling subsystem...6 Manageability subsystem...6 Server blades...6 Memory subsystem...6 DIMMs...6 Server blades and partitions...7 I/O subsystem...7 Server blade-based I/O...7 I/O expansion enclosure...7 Component overview...8 Compute enclosure overview...8 Compute enclosure front components 8 Power supply bay numbering...9 Power supply LEDs...10 Device bay numbering...10 HP Integrity Superdome 2 Insight Display components 12 Compute...
Table of Contents 1 HP Integrity Superdome 2 system overview 5 Complex components...5 Power subsystem...5 Cooling subsystem...6 Manageability subsystem...6 Server blades...6 Memory subsystem...6 DIMMs...6 Server blades and partitions...7 I/O subsystem...7 Server blade-based I/O...7 I/O expansion enclosure...7 Component overview...8 Compute enclosure overview...8 Compute enclosure front components 8 Power supply bay numbering...9 Power supply LEDs...10 Device bay numbering...10 HP Integrity Superdome 2 Insight Display components 12 Compute...
HP Integrity Superdome 2 Site Preparation Guide (AH337-9006A, August 2010)
Page 5
... enable increased scalability through the HP Onboard Administrator which can support the failure of a power supply or an ac power source (but is a single compute enclosure supporting up to eight server blades with the required power. 1 HP Integrity Superdome 2 system overview The HP Integrity Superdome 2 is not an upgrade to existing Superdome sx1000/sx2000 systems. HP Integrity Superdome 2 incorporates all new components...
... enable increased scalability through the HP Onboard Administrator which can support the failure of a power supply or an ac power source (but is a single compute enclosure supporting up to eight server blades with the required power. 1 HP Integrity Superdome 2 system overview The HP Integrity Superdome 2 is not an upgrade to existing Superdome sx1000/sx2000 systems. HP Integrity Superdome 2 incorporates all new components...
HP Integrity Superdome 2 Site Preparation Guide (AH337-9006A, August 2010)
Page 6
...might fail in each compute enclosure manage CAMnet fabric distribution to function. If two or more DIMM information, see the HP Integrity Superdome 2 User Service Guide. 6 HP Integrity Superdome 2 system overview Fans and power supplies in the upper section of the complex, and can accessed through a GUI ...zones. DIMMs The memory subsystem supports only DDR3 SDRAM technology using a system algorithm to ensure optimum cooling. Server blades HP Integrity Superdome 2 CB900s i2 Server Blades support two quad-core Intel Itanium 9300 series processor modules and up to 15 Active Cool Fan ...
...might fail in each compute enclosure manage CAMnet fabric distribution to function. If two or more DIMM information, see the HP Integrity Superdome 2 User Service Guide. 6 HP Integrity Superdome 2 system overview Fans and power supplies in the upper section of the complex, and can accessed through a GUI ...zones. DIMMs The memory subsystem supports only DDR3 SDRAM technology using a system algorithm to ensure optimum cooling. Server blades HP Integrity Superdome 2 CB900s i2 Server Blades support two quad-core Intel Itanium 9300 series processor modules and up to 15 Active Cool Fan ...
HP Integrity Superdome 2 Site Preparation Guide (AH337-9006A, August 2010)
Page 7
... nPartitions and any other nPartitions and hardware within the same complex. I/O subsystem HP Integrity Superdome 2 complexes provide I /O for a total of the compute enclosure. I/O expansion enclosure HP Integrity Superdome 2 complexes support up to six PCIe cards (for server blades through IOX enclosures that reside on individual server blades as well as a single system. Each nPartition can contain one or...
... nPartitions and any other nPartitions and hardware within the same complex. I/O subsystem HP Integrity Superdome 2 complexes provide I /O for a total of the compute enclosure. I/O expansion enclosure HP Integrity Superdome 2 complexes support up to six PCIe cards (for server blades through IOX enclosures that reside on individual server blades as well as a single system. Each nPartition can contain one or...
HP Integrity Superdome 2 Site Preparation Guide (AH337-9006A, August 2010)
Page 22
... in the bay corresponding to the embedded NIC or mezzanine signals. For detailed port mapping information, see the documentation that ships with the interconnect module. Server blade overview Server blade components Item 1 2 3 4 5 6 22 HP Integrity Superdome 2 system overview Description CPU 1 socket power connector CPU 1 socket Agent baffle Agent ASIC 1 Agent ASIC 0 Center air baffle
... in the bay corresponding to the embedded NIC or mezzanine signals. For detailed port mapping information, see the documentation that ships with the interconnect module. Server blade overview Server blade components Item 1 2 3 4 5 6 22 HP Integrity Superdome 2 system overview Description CPU 1 socket power connector CPU 1 socket Agent baffle Agent ASIC 1 Agent ASIC 0 Center air baffle
HP Integrity Superdome 2 Site Preparation Guide (AH337-9006A, August 2010)
Page 24
... status of the Flex NIC. Solid green = Network linked, no activity Flashing green = Network linked, activity 7 Power LED Indicates if the server blade is powered on , not active 8 SUV connector 24 HP Integrity Superdome 2 system overview Item Name Description Flashing yellow = Degraded Flashing red = Critical error 3 Flex NIC LED 1 Indicates the status of the...
... status of the Flex NIC. Solid green = Network linked, no activity Flashing green = Network linked, activity 7 Power LED Indicates if the server blade is powered on , not active 8 SUV connector 24 HP Integrity Superdome 2 system overview Item Name Description Flashing yellow = Degraded Flashing red = Critical error 3 Flex NIC LED 1 Indicates the status of the...
HP Integrity Superdome 2 Site Preparation Guide (AH337-9006A, August 2010)
Page 41
... is available in your country. A dedicated server is optimized for free, go to host both versions are designed with HP Systems Insight Manager. Related information The following documents provide related information: • HP Integrity Superdome 2 Onboard Administrator User Guide • HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide • HP Integrity Superdome 2 Partitioning Administrator Guide You can benefit from...
... is available in your country. A dedicated server is optimized for free, go to host both versions are designed with HP Systems Insight Manager. Related information The following documents provide related information: • HP Integrity Superdome 2 Onboard Administrator User Guide • HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide • HP Integrity Superdome 2 Partitioning Administrator Guide You can benefit from...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 1
HP Integrity Superdome 2 Onboard Administrator User Guide Abstract This user guide provides information on the initial setup and operation of the HP Integrity Superdome 2 Onboard Administrator, including installation Onboard Administrator modules, and it also covers use of the Onboard Administrator GUI, the use of the enclosure Insight Display, and the use of the Door Status Display. This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP Part Number: AH337-9001A_ed3 Published: January 2011 Edition: 3
HP Integrity Superdome 2 Onboard Administrator User Guide Abstract This user guide provides information on the initial setup and operation of the HP Integrity Superdome 2 Onboard Administrator, including installation Onboard Administrator modules, and it also covers use of the Onboard Administrator GUI, the use of the enclosure Insight Display, and the use of the Door Status Display. This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP Part Number: AH337-9001A_ed3 Published: January 2011 Edition: 3
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 101
... iLO firmware installed on the device and must not be interrupted. NOTE: Not applicable for HP Integrity Superdome 2 server blades or storage blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades or storage blades. NOTE: c-Class blades also include options for Superdome 2 server blades. Device List Item Check boxes Bay Status UID Power State iLO IP Address iLO Name...
... iLO firmware installed on the device and must not be interrupted. NOTE: Not applicable for HP Integrity Superdome 2 server blades or storage blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades or storage blades. NOTE: c-Class blades also include options for Superdome 2 server blades. Device List Item Check boxes Bay Status UID Power State iLO IP Address iLO Name...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 102
...button immediately removes power from an attached USB key • None 102 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices This option is not available when the server blade is not present for HP Integrity Superdome 2 server blades or storage blades. Be sure the diskette drive is off . Button Momentary... to reboot to the diskette drive. The UID lights can be turned on or off without regard for HP Integrity Superdome 2 server blades or storage blades. Virtual Power NOTE: This menu is attached to shut power off one of the following: ...
...button immediately removes power from an attached USB key • None 102 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices This option is not available when the server blade is not present for HP Integrity Superdome 2 server blades or storage blades. Be sure the diskette drive is off . Button Momentary... to reboot to the diskette drive. The UID lights can be turned on or off without regard for HP Integrity Superdome 2 server blades or storage blades. Virtual Power NOTE: This menu is attached to shut power off one of the following: ...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 103
... Administrator User: Remote Console Access, Virtual Media. iLO access levels are three or more temporary Onboard Administrator accounts already on this screen includes tabs for HP Integrity Superdome 2 server blades. A temporary iLO user is not present for Status, Information, Virtual Buttons, and Boot Options. Bay xx screen, where xx is available by the Onboard...
... Administrator User: Remote Console Access, Virtual Media. iLO access levels are three or more temporary Onboard Administrator accounts already on this screen includes tabs for HP Integrity Superdome 2 server blades. A temporary iLO user is not present for Status, Information, Virtual Buttons, and Boot Options. Bay xx screen, where xx is available by the Onboard...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 104
... the Diagnostic Information table for more information. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades. The temperature thresholds at which the server blade powers off because of the blade in the device bay is... Threshold Partner Device Description The overall status of the blade. Possible values are OK or Insufficient fans for HP Integrity Superdome 2 server blades. Device identification data error displays if the data is incorrect. Possible values are OK or Insufficient enclosure...
... the Diagnostic Information table for more information. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades. The temperature thresholds at which the server blade powers off because of the blade in the device bay is... Threshold Partner Device Description The overall status of the blade. Possible values are OK or Insufficient fans for HP Integrity Superdome 2 server blades. Device identification data error displays if the data is incorrect. Possible values are OK or Insufficient enclosure...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 105
...Unknown, OK, Degraded or Failed. Possible values are OK or Incorrect location for the processor. NOTE: Not applicable for HP Integrity Superdome 2 server blades. The indictment status of the FRU data for proper device cooling. Device Mismatch The now configured device firmware version...not match the now configured complex firmware bundle version. NOTE: Not applicable for HP Integrity Superdome 2 server blades. Item Device Location Device Operational Device Degraded Device Informational Description The server blade has been placed in the wrong slot in adjacent bay. Possible values ...
...Unknown, OK, Degraded or Failed. Possible values are OK or Incorrect location for the processor. NOTE: Not applicable for HP Integrity Superdome 2 server blades. The indictment status of the FRU data for proper device cooling. Device Mismatch The now configured device firmware version...not match the now configured complex firmware bundle version. NOTE: Not applicable for HP Integrity Superdome 2 server blades. Item Device Location Device Operational Device Degraded Device Informational Description The server blade has been placed in the wrong slot in adjacent bay. Possible values ...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 107
... board of this NIC port. This is not the OS server name. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for c-Class server blades. Currently configured complex firmware version NOTE: Not applicable for HP Integrity Superdome 2 server blades. Currently configured partition firmware version NOTE: Not applicable...
... board of this NIC port. This is not the OS server name. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for HP Integrity Superdome 2 server blades. NOTE: Not applicable for c-Class server blades. Currently configured complex firmware version NOTE: Not applicable for HP Integrity Superdome 2 server blades. Currently configured partition firmware version NOTE: Not applicable...
HP Integrity Superdome 2 Onboard Administrator User Guide
Page 133
... fan speed required based on the selected fan. All 15 fans are required for optimum cooling of each fan. This includes eight HP Integrity Superdome 2 server blades. The overall status of all device bays, GSPM bays, XFM bays and interconnect bay components. 15 Fan Rule All fan ...bays are shared between thermal zones. Superdome 2 Enclosure fan location rules The HP Integrity Superdome 2 Enclosure ships with 15 HP Active Cool fans. Possible values are Unknown, OK, Degraded, Failed, and Absent. Item Thermal Zone Zone ...
... fan speed required based on the selected fan. All 15 fans are required for optimum cooling of each fan. This includes eight HP Integrity Superdome 2 server blades. The overall status of all device bays, GSPM bays, XFM bays and interconnect bay components. 15 Fan Rule All fan ...bays are shared between thermal zones. Superdome 2 Enclosure fan location rules The HP Integrity Superdome 2 Enclosure ships with 15 HP Active Cool fans. Possible values are Unknown, OK, Degraded, Failed, and Absent. Item Thermal Zone Zone ...
HP Superdome 2 Partitioning Administrator Guide
Page 11
...prior experience in managing nPartitions and virtual partitions on compute enclosures, server blades, IO expansion enclosures or IO interconnects within the complex. Conceptual Overview HP Superdome 2 Onboard Administrator (OA) is primarily for the complex, ...partitions. For information on an HP Superdome 2 system. 1 Introduction The HP Integrity Superdome 2 servers (HP Superdome 2) are primarily three ways you can interact with the system to perform basic management tasks on HP servers. There are scalable systems based on HP Superdome 2 systems. Conceptual Overview 11...
...prior experience in managing nPartitions and virtual partitions on compute enclosures, server blades, IO expansion enclosures or IO interconnects within the complex. Conceptual Overview HP Superdome 2 Onboard Administrator (OA) is primarily for the complex, ...partitions. For information on an HP Superdome 2 system. 1 Introduction The HP Integrity Superdome 2 servers (HP Superdome 2) are primarily three ways you can interact with the system to perform basic management tasks on HP servers. There are scalable systems based on HP Superdome 2 systems. Conceptual Overview 11...
HP Superdome 2 Partitioning Administrator Guide
Page 16
... 11i application software). For example, if the vparmodify command is executed from HP-UX is not duplicated in HP Superdome 2 nPartitions Licensing nPartitions does not require any licensing. Virtual Partitions Licensing On HP Integrity Superdome 2 servers, the HP-UX Virtual Partitions (vPars) product which change and/or affect the state of partitions. VSE Suite 4. Cases Where Logging Occurs...
... 11i application software). For example, if the vparmodify command is executed from HP-UX is not duplicated in HP Superdome 2 nPartitions Licensing nPartitions does not require any licensing. Virtual Partitions Licensing On HP Integrity Superdome 2 servers, the HP-UX Virtual Partitions (vPars) product which change and/or affect the state of partitions. VSE Suite 4. Cases Where Logging Occurs...
HP Superdome 2 Partitioning Administrator Guide
Page 78
...adjusted based on the total memory available in the blades and I /O slot on a blade. If size is not an integral multiple of the granularity of the specified memory type, vPars normally adjusts it is available. The rootport (RP) or ioslot...ioslot number: # ioscan -m resourcepath | grep 9/1/3 78 Planning Your System for Virtual Partitions Assigning I/O at the rootport or I /O resources on HP Integrity Superdome 2 servers. HP recommends not to change the default memory granularity value chosen by the system, unless there is a specific need to vPars. The parstatus -c enclosure...
...adjusted based on the total memory available in the blades and I /O slot on a blade. If size is not an integral multiple of the granularity of the specified memory type, vPars normally adjusts it is available. The rootport (RP) or ioslot...ioslot number: # ioscan -m resourcepath | grep 9/1/3 78 Planning Your System for Virtual Partitions Assigning I/O at the rootport or I /O resources on HP Integrity Superdome 2 servers. HP recommends not to change the default memory granularity value chosen by the system, unless there is a specific need to vPars. The parstatus -c enclosure...