Operation Manual
Page 1
Aqua Plus 16v Automation and Chlorination Operation Manual for model PL-PLUS-16V www.haywardnet.com
Aqua Plus 16v Automation and Chlorination Operation Manual for model PL-PLUS-16V www.haywardnet.com
Operation Manual
Page 3
... and Cleaning the Chorinator Cell 39 Winterizing 39 Spring Startup 39 Troubleshooting & Diagnostic Information Service Mode 40 Check System Indicator 40 Diagnostic Menu 42 Warranty Aqua Plus 16v Warranty 48 Manually 33 Operate the Spa - Automatically 33 Set the Heater Temperature 33 Set the Chlorinator Output 33 Start/Stop Superchlorination 34 Program...
... and Cleaning the Chorinator Cell 39 Winterizing 39 Spring Startup 39 Troubleshooting & Diagnostic Information Service Mode 40 Check System Indicator 40 Diagnostic Menu 42 Warranty Aqua Plus 16v Warranty 48 Manually 33 Operate the Spa - Automatically 33 Set the Heater Temperature 33 Set the Chlorinator Output 33 Start/Stop Superchlorination 34 Program...
Operation Manual
Page 4
...OFF ON AUX2 OFF Optional Wireless Remote Display Keypad Optional Wireless Base Receiver Aqua Plus 16 Main Display Keypad Optional Wired Remote Display Keypad (maximum of the Aqua Plus 16v that the Aqua Plus 16v has been wired and configured according to system setup are available. ...of equipment, up to fully manage your pool/spa system. System Overview The Hayward Aqua Plus 16v is a multifunction pool controller used to 4 automatic valve actuators, and 2 conventional heaters plus a solar heater. The Aqua Plus 16v can control up to 8 high voltage (120/240V) pieces of the...
...OFF ON AUX2 OFF Optional Wireless Remote Display Keypad Optional Wireless Base Receiver Aqua Plus 16 Main Display Keypad Optional Wired Remote Display Keypad (maximum of the Aqua Plus 16v that the Aqua Plus 16v has been wired and configured according to system setup are available. ...of equipment, up to fully manage your pool/spa system. System Overview The Hayward Aqua Plus 16v is a multifunction pool controller used to 4 automatic valve actuators, and 2 conventional heaters plus a solar heater. The Aqua Plus 16v can control up to 8 high voltage (120/240V) pieces of the...
Operation Manual
Page 5
...sanitize a pool varies due to sodium chloride after killing bacteria. Chlorine will continuously recycle, virtually eliminating the need to add more Hayward Aqua Rite chlorinators to backwashing, draining, or splashing (not evaporation). Check local codes for immediately adjacent patios/decking, a qualified stone installation...due to supplement chlorine production. The only time you about system operation. For pools larger than 40,000 gallons, the Aqua Plus 16v can control one or more salt to the pool/spa is when water is not commonly diluted with electronic chlorine generator...
...sanitize a pool varies due to sodium chloride after killing bacteria. Chlorine will continuously recycle, virtually eliminating the need to add more Hayward Aqua Rite chlorinators to backwashing, draining, or splashing (not evaporation). Check local codes for immediately adjacent patios/decking, a qualified stone installation...due to supplement chlorine production. The only time you about system operation. For pools larger than 40,000 gallons, the Aqua Plus 16v can control one or more salt to the pool/spa is when water is not commonly diluted with electronic chlorine generator...
Operation Manual
Page 6
...Buttons Aux1 - Pressing the "FILTER" button again will read "POOL FILTER". Aux14 (On/Off) Valve4 or Heater2 (See Configuration Menu) Output Names The Aqua Plus 16v is shipped from then on. When in Dual Equipment mode, the display will turn off , press the "FILTER" button to turn it will ...configured, this point the filter pump will refer to the pool filter pump as "FILTER". Manual System Operation While the main objective of the Aqua Plus 16v is to automate the operation of your pool/spa system, there may be manually operated whether in Standard (single pump) or Dual Equipment...
...Buttons Aux1 - Pressing the "FILTER" button again will read "POOL FILTER". Aux14 (On/Off) Valve4 or Heater2 (See Configuration Menu) Output Names The Aqua Plus 16v is shipped from then on. When in Dual Equipment mode, the display will turn off , press the "FILTER" button to turn it will ...configured, this point the filter pump will refer to the pool filter pump as "FILTER". Manual System Operation While the main objective of the Aqua Plus 16v is to automate the operation of your pool/spa system, there may be manually operated whether in Standard (single pump) or Dual Equipment...
Operation Manual
Page 7
... is identical. On 100%). When the Lights or Aux output comes on again (either manually or automatically), the dimmer output level will be in Hayward Generation 4 or later ColorLogic pool and spa lights. The "Filter" LED will illuminate continuously. Pushing the "+" or "-" button changes the speed .... Assuming that it probably is due to the "interlock" feature (which shows the dimmer output level (Off - The Network Module allows the Aqua Plus 16v to low speed operation and the "AUX1" LED will flash. If the pump has been off for 3 minutes regardless of the filter ...
... is identical. On 100%). When the Lights or Aux output comes on again (either manually or automatically), the dimmer output level will be in Hayward Generation 4 or later ColorLogic pool and spa lights. The "Filter" LED will illuminate continuously. Pushing the "+" or "-" button changes the speed .... Assuming that it probably is due to the "interlock" feature (which shows the dimmer output level (Off - The Network Module allows the Aqua Plus 16v to low speed operation and the "AUX1" LED will flash. If the pump has been off for 3 minutes regardless of the filter ...
Operation Manual
Page 8
..., and the remote display/keypads are turning. Pressing the "POOL/SPA/SPILLOVER" button again will return the Aqua Plus 16v to normal (automatic) operation. Dual Equipment Pool and Spa systems without spa spillover: In pool-only mode... switch back to switch the heater control output between a "forced off . ! Pressing the "HEATER" button causes the Aqua Plus 16v to pool-only mode. WARNING: pressing the "SYSTEM OFF" button overrides any remote display/keypad) is pressed again.../SPA/SPILLOVER" button to switch to supply power and control a Hayward Variable Speed pump (VSP).
..., and the remote display/keypads are turning. Pressing the "POOL/SPA/SPILLOVER" button again will return the Aqua Plus 16v to normal (automatic) operation. Dual Equipment Pool and Spa systems without spa spillover: In pool-only mode... switch back to switch the heater control output between a "forced off . ! Pressing the "HEATER" button causes the Aqua Plus 16v to pool-only mode. WARNING: pressing the "SYSTEM OFF" button overrides any remote display/keypad) is pressed again.../SPA/SPILLOVER" button to switch to supply power and control a Hayward Variable Speed pump (VSP).
Operation Manual
Page 9
... up or down (example: heater temperature setting or timeclock on the display. Only menu items that are used for each function. Automatic System Operation The Aqua Plus 16v controls most of your pool equipment automatically in " your new setting. After you have adjusted the item to the desired value, simply move on... get to programming any function: 1. Press either the main display/keypad located at the pool equipment pad or the in for an extended period. 6 The Aqua Plus 16v memory will appear. (Example: if you on a timeclock basis.
... up or down (example: heater temperature setting or timeclock on the display. Only menu items that are used for each function. Automatic System Operation The Aqua Plus 16v controls most of your pool equipment automatically in " your new setting. After you have adjusted the item to the desired value, simply move on... get to programming any function: 1. Press either the main display/keypad located at the pool equipment pad or the in for an extended period. 6 The Aqua Plus 16v memory will appear. (Example: if you on a timeclock basis.
Operation Manual
Page 11
..." position and the filter pump is running and the spa water temperature is enabled. The Default Menu is used by a pool professional. The Aqua Plus 16v will automatically switch to the section regarding the Configuration menu can be assigned to each piece of the Timers Menu. ! The Settings Menu ...or "pool and spa" operation and the "Heater1" and/or "Heater2" control is tied to customize the operation of your pool/spa equipment. The Aqua Plus 16v allows more information). Spa Heater1 Off not shown if Pool and Spa-Dual with separate heaters ("Pool and Spa -Dual" and "Htr1=Spa,...
..." position and the filter pump is running and the spa water temperature is enabled. The Default Menu is used by a pool professional. The Aqua Plus 16v will automatically switch to the section regarding the Configuration menu can be assigned to each piece of the Timers Menu. ! The Settings Menu ...or "pool and spa" operation and the "Heater1" and/or "Heater2" control is tied to customize the operation of your pool/spa equipment. The Aqua Plus 16v allows more information). Spa Heater1 Off not shown if Pool and Spa-Dual with separate heaters ("Pool and Spa -Dual" and "Htr1=Spa,...
Operation Manual
Page 13
...condition, or any display/keypad), the super chlorinate function terminates. At the end of chlorine to be introduced to the pool, activate the Aqua Plus 16v Super Chlorinate function. It will determine the chlorinator output when the system is being used , super chlorinate will not operate during high speed...previous/next menu item This menu will turn off the filter pump (using dual equipment, this is the pool filter low speed. The Aqua Plus 16v will appear if an aux has been configured as "ColorLogic". When you manually turn on any other condition that requires a large ...
...condition, or any display/keypad), the super chlorinate function terminates. At the end of chlorine to be introduced to the pool, activate the Aqua Plus 16v Super Chlorinate function. It will determine the chlorinator output when the system is being used , super chlorinate will not operate during high speed...previous/next menu item This menu will turn off the filter pump (using dual equipment, this is the pool filter low speed. The Aqua Plus 16v will appear if an aux has been configured as "ColorLogic". When you manually turn on any other condition that requires a large ...
Operation Manual
Page 14
... Display Light selection only applies to Beeper Enabled. NOTE: This function is pressed. If the "Enabled" selection is displayed, then the Aqua Plus 16v can not communicate with any button on wireless remote Move to previous/next menu item Move to previous/next menu item Move to previous...setting Set Day and Time Wednesday 10: P Adjust the current minute Move to previous/next menu item Use this function to this particular Aqua Plus 16v unit and will reject messages with the transmitter/ receiver base station attached to keep the clock running during power outages lasting less than...
... Display Light selection only applies to Beeper Enabled. NOTE: This function is pressed. If the "Enabled" selection is displayed, then the Aqua Plus 16v can not communicate with any button on wireless remote Move to previous/next menu item Move to previous/next menu item Move to previous...setting Set Day and Time Wednesday 10: P Adjust the current minute Move to previous/next menu item Use this function to this particular Aqua Plus 16v unit and will reject messages with the transmitter/ receiver base station attached to keep the clock running during power outages lasting less than...
Operation Manual
Page 15
...time equal to the off or, when the programmed time has elapsed, the output will only appear if a wireless base station is connected to the Aqua Plus 16v. If you to set above. The Countdown timer is programmed in 15 minute increments (9:00A, 9:15A, 9:30A, etc.). When a countdown ...the "+" or "-" buttons to go back to a normal timeclock programming display. All times are several reasons the filter pump may be re-taught. The Aqua Plus 16v allows more information). For pool/spa combination systems with "Filter Hi"). There are adjusted in increments of 5 minutes from "Manual On/Off" (0 ...
...time equal to the off or, when the programmed time has elapsed, the output will only appear if a wireless base station is connected to the Aqua Plus 16v. If you to set above. The Countdown timer is programmed in 15 minute increments (9:00A, 9:15A, 9:30A, etc.). When a countdown ...the "+" or "-" buttons to go back to a normal timeclock programming display. All times are several reasons the filter pump may be re-taught. The Aqua Plus 16v allows more information). For pool/spa combination systems with "Filter Hi"). There are adjusted in increments of 5 minutes from "Manual On/Off" (0 ...
Operation Manual
Page 16
..., this function. For two speed or variable speed pumps, this timeclock will drop down to the programmed spa temperature. During the programmed spa time, the Aqua Plus 16v will first turn on this programmed time period. Set DSapyaa-nadll Time W6ed:0n0esPdtaoy 91:00:03P7P or Spa-wkend 6:00P to 9:00P Adjust... for more than 30 seconds, the pump will move the pool/spa valves into the "spa-only" position and turn on the lights until the Aqua Plus 16v automatically turns off at high speed for the remainder of the filter button or pool/spa valve button will turn on the filter pump...
..., this function. For two speed or variable speed pumps, this timeclock will drop down to the programmed spa temperature. During the programmed spa time, the Aqua Plus 16v will first turn on this programmed time period. Set DSapyaa-nadll Time W6ed:0n0esPdtaoy 91:00:03P7P or Spa-wkend 6:00P to 9:00P Adjust... for more than 30 seconds, the pump will move the pool/spa valves into the "spa-only" position and turn on the lights until the Aqua Plus 16v automatically turns off at high speed for the remainder of the filter button or pool/spa valve button will turn on the filter pump...
Operation Manual
Page 17
... period set the normal time period for spa filter pump low speed operation (the word "Spa Filter T2" in the pool-only position-the Aqua Plus 16v will be running and the pool/spa valves are suitable for operation. If the filter pump is only available if the system has been...times & to page 12 for general notes regarding timeclock programming. The Aux1 output will operate in the display will keep the relay off until the Aqua Plus 16v automatically turns off at an earlier time by pressing the AUX1 button. 14 If the high speed and low speed periods overlap, then the...
... period set the normal time period for spa filter pump low speed operation (the word "Spa Filter T2" in the pool-only position-the Aqua Plus 16v will be running and the pool/spa valves are suitable for operation. If the filter pump is only available if the system has been...times & to page 12 for general notes regarding timeclock programming. The Aux1 output will operate in the display will keep the relay off until the Aqua Plus 16v automatically turns off at an earlier time by pressing the AUX1 button. 14 If the high speed and low speed periods overlap, then the...
Operation Manual
Page 18
... on and off the pool light only, the button can also manually turn on and off based on the valve3 relay until the Aqua Plus 16v automatically turns off the pool cleaner, turn on and dim the patio lights, turn on this section when programming Group commands. ...10, 0:15...) Wednes0d:a2y010:37P Move to be configured. Smaller pools require less hours of Superchlorination. This convenient feature is configured for timeclock. The Aqua Plus 16v can not do both Valve buttons and the Lights button. Refer to a particular button. The options for controlling groups are to previous/next ...
... on and off the pool light only, the button can also manually turn on and off based on the valve3 relay until the Aqua Plus 16v automatically turns off the pool cleaner, turn on and dim the patio lights, turn on this section when programming Group commands. ...10, 0:15...) Wednes0d:a2y010:37P Move to be configured. Smaller pools require less hours of Superchlorination. This convenient feature is configured for timeclock. The Aqua Plus 16v can not do both Valve buttons and the Lights button. Refer to a particular button. The options for controlling groups are to previous/next ...
Operation Manual
Page 19
For example, if the Aqua Plus 16v is running, go to the Settings menu and press the +/- Also, under the Lights menu, the ...50% Unaffected, 20% to Highest speed Unaffected, Lowest speed to the normal heater setting. The available functions are in Groups The Aqua Plus 16v can 't be retained as an option and the Lights function will depend on when the group is activated. All other parameters ...for a single heater, "Heater2" will not be available as an option and will automatically turn on how the Aqua Plus 16v is activated, the temperature will affect the normal heater setting.
For example, if the Aqua Plus 16v is running, go to the Settings menu and press the +/- Also, under the Lights menu, the ...50% Unaffected, 20% to Highest speed Unaffected, Lowest speed to the normal heater setting. The available functions are in Groups The Aqua Plus 16v can 't be retained as an option and the Lights function will depend on when the group is activated. All other parameters ...for a single heater, "Heater2" will not be available as an option and will automatically turn on how the Aqua Plus 16v is activated, the temperature will affect the normal heater setting.
Operation Manual
Page 20
... return to the group speed setting that are T-CELL-15 (default), T-CELL-9, T-CELL-5 or T-CELL-3. The cell and flow switch must be installed and the Aqua Plus 16v will be suppressed. "T-CELL-3" = T-CELL-3, GLX-CELL-3-W "T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W "T-CELL-9" = T-CELL-9, GLX-CELL-9-W "T-CELL-15" = T-... Salt (default) and Minerals Move to previous/next configuration menu Rotates between available Cell types Move to next menu item Chlorinator The Aqua Plus 16v is running, go to the Settings menu and press the +/- Super Chlorinate will return to the normal speed setting. When the...
... return to the group speed setting that are T-CELL-15 (default), T-CELL-9, T-CELL-5 or T-CELL-3. The cell and flow switch must be installed and the Aqua Plus 16v will be suppressed. "T-CELL-3" = T-CELL-3, GLX-CELL-3-W "T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W "T-CELL-9" = T-CELL-9, GLX-CELL-9-W "T-CELL-15" = T-... Salt (default) and Minerals Move to previous/next configuration menu Rotates between available Cell types Move to next menu item Chlorinator The Aqua Plus 16v is running, go to the Settings menu and press the +/- Super Chlorinate will return to the normal speed setting. When the...
Operation Manual
Page 21
...detailed information. The filter is the time, after you manually switch the Pool/Spa valves to "Spa Only", until the Aqua Plus 16v automatically returns the valves to the Aqua Plus 16v. Refer to the AQL-CHEM manual for Heater1 to be dedicated to the spa and Heater2 to be connected to...Chemistry Config. Pressing the POOL/SPA button on during this time period. Wizard + to enter Press to "Pool and Spa-Dual". Wizard Move to the Aqua Plus 16v. If "Pool and Spa-Dual" is set to previous/next configuration menu Pool/Spa Setup If "Pool Only" or "Spa Only" are selected...
...detailed information. The filter is the time, after you manually switch the Pool/Spa valves to "Spa Only", until the Aqua Plus 16v automatically returns the valves to the Aqua Plus 16v. Refer to the AQL-CHEM manual for Heater1 to be dedicated to the spa and Heater2 to be connected to...Chemistry Config. Pressing the POOL/SPA button on during this time period. Wizard + to enter Press to "Pool and Spa-Dual". Wizard Move to the Aqua Plus 16v. If "Pool and Spa-Dual" is set to previous/next configuration menu Pool/Spa Setup If "Pool Only" or "Spa Only" are selected...
Operation Manual
Page 22
...and/or the super chlorinate is running. The pump will NOT shut off for the remainder of small name labels is included with the Aqua Plus 16v main unit and each remote display/keypad so that appropriate pushbuttons can be filtered and sanitized. When disabled (default), the return ... previous/next configuration menu Filter Name Pool Filter Rotates between Enabled and Disabled (default) Move to previous/next configuration menu Filter Name The Aqua Plus 16v allows you have assigned. 19 The valves will remain in the Heater Cooldown mode. V1=Aux1, V2=Aux2 This menu appears only...
...and/or the super chlorinate is running. The pump will NOT shut off for the remainder of small name labels is included with the Aqua Plus 16v main unit and each remote display/keypad so that appropriate pushbuttons can be filtered and sanitized. When disabled (default), the return ... previous/next configuration menu Filter Name Pool Filter Rotates between Enabled and Disabled (default) Move to previous/next configuration menu Filter Name The Aqua Plus 16v allows you have assigned. 19 The valves will remain in the Heater Cooldown mode. V1=Aux1, V2=Aux2 This menu appears only...
Operation Manual
Page 23
... the "Check System" LED will indicate an error. When the filter pump output is configured for freeze protection. When used with a Hayward flow switch, the Aqua Plus 16v monitors the state of water flow when the filter pump is default. Temperature is adjustable from 33ºF-42ºF (1ºC6...pump will be on due to no flow is enabled and the AIR temperature sensor falls below ), the Aqua Plus 16v will be used for 2-speed and variable speed pump operation. For the Hayward variable speed pump: The Filter relay is active. The relay will turn on . Set lowest speed ...
... the "Check System" LED will indicate an error. When the filter pump output is configured for freeze protection. When used with a Hayward flow switch, the Aqua Plus 16v monitors the state of water flow when the filter pump is default. Temperature is adjustable from 33ºF-42ºF (1ºC6...pump will be on due to no flow is enabled and the AIR temperature sensor falls below ), the Aqua Plus 16v will be used for 2-speed and variable speed pump operation. For the Hayward variable speed pump: The Filter relay is active. The relay will turn on . Set lowest speed ...