Universal H Series Troubleshooting Guide - Page 3

...-33 5. "LO" Code 46-51 12. "IF" Code 52-55 13. "AC" Code 56-57 14. "SF" or "HS" Code 9. Open FC1&/FC2 Fuse 27-28 3. "EE" or "CE" Code 36-37 Troubleshooting (cont.): 7. "AO" Code 58-60 Heat Exchanger: Flow requirements 61 Heat Exchanger: Inspection 62 Heat Exchanger: Potential Failure Causes 63 UHS Wiring Schematic 64 UHS Wiring Diagram 65 3 "BD" Code 34...
Universal H Series Troubleshooting Guide - Page 7

... actual water temp. Gas valve opens and monitors flame sense. The gas valve is de-energized, and the flame is de-energized at flame sense or at completion of Operation: Normal The control continually compares the set temp to light operations. 7 At proper ignitor temp, a 4 second trial begins. The blower will operate for heat. If the...
Universal H Series Troubleshooting Guide - Page 8

... fails: 1. Waits 60 minutes then retries 3 more times. 5. UHS Sequence of Operation: Failure to retry every 60 minutes, until lockout (IF code). 4. NOTE: When making keypad entries of heating mode sequence. 3. Gas valve de-energizes (for 30 second, blower post purge). 2. Starts over at #2 of any type there may be a 5-10 sec delay for...
Universal H Series Troubleshooting Guide - Page 17

... low, go to step 4. IF it does, continue to reduce pressure). *NOTE: Before any adjustment occurs, verify inlet gas pressure meets the requirement set forth by the data plate on the heater. Once removed, increase pressure by rotating valve clockwise, (counter clockwise to step 4. IF NOT, refer to installation manual and/or contact installer. 17 Remove plug.
Universal H Series Troubleshooting Guide - Page 27

... wiring damaged, pinched, or worn? NO Test transformer resistance Is resistance YES correct? Open FC1 &/or F2 Fuse Open FC1 &/or F2 Fuse Problem solved Correct voltage YES selector plug? NO Correct/repair transformer wiring Contact Support (908) 355-7995 Replace transformer: IDXL2TRF1930 27 NO Install correct plug and replace fuse YES Did this correct the...
Universal H Series Troubleshooting Guide - Page 36

... secure? NO Replace ICB: FDXLICB1930 Problem solved Did "CE" code YES clear? NO Section B Replace ICB: FDXLICB1930 YES Did the "CE" code clear? NO Check display ribbon cable connection Secure connections & retest Problem solved Contact Support (908) 355-7995 NO Go to section B The "CE" code may clear with a reset of power, power cycle the heater YES Did the...
Universal H Series Troubleshooting Guide - Page 40

... red to YES black, do the readings differ by more than 1°? NO Replace thermistor: FDXLTER1930 Plumb correctly in compliance with installation manual Replace ICB: FDXLICB1930 Make sure water inlet & outlet are YES plumbed correctly, are they reversed? Service LED ON: "SF" OR "HS" Code "SF" OR "HS" Code Check display for High Sense (water temperature). 8. NO...
Universal H Series Troubleshooting Guide - Page 44

NO Did the "HF" YES code reappear? NO Test for heat YES Is 24VAC present? NO Verify error code & jump to section that best describes error Replace gas valve: Please refer to (pg. 20) 44 Reduce the temperature set point until heater stop firing Problem solved Did the "HF" YES code reappear? Service LED ON: "HF" Code "HF" Code Power cycle the heater at the breaker Does...
Universal H Series Troubleshooting Guide - Page 45

... is sensed when the gas valve is defective and needs to be replaced. IF "HF" reappears, go into lockout. IF power cycling clears to the "HF" message and the heater fires, drop the temperature to toggle the heater and call for 5 seconds then restart heater after 2 minutes. Service LED ON: "HF" Code (cont.) "HF" (heat or flame sensed) will...
Universal H Series Troubleshooting Guide - Page 46

Service LED ON: "LO" Code "LO" Code Verify adequate water flow, is continuity present? YES Is water pressure switch wiring free of damage? NO NO 46 Replace exhaust gas limit switch: FDXLEGL1930 YES Are wires free of damage? NO Contact Support (908) 355-7995 Did error YES clear? Heater made after Feb. 2016? 11. Verify high limit wires are free of...
Universal H Series Troubleshooting Guide - Page 51

... be replaced and the heat exchanger should be inspected for soot or damage. Service LED ON: "LO" Code (cont.) Note: This switch is a one time safety. IF open, replace switch (pg. 20). 11. Indoor/Outdoor: Feb. 2016 and newer Step 11I Test continuity across the exhaust gas limit switch. IF switch does not exist AND problem still persists, contact support...
Universal H Series Troubleshooting Guide - Page 52

... manifold gas pressure Replace gas valve: Replace ICB: 52 Please refer to gas valve during call for heat pressure correct? 12. NO YES Is voltage correct? Service LED ON: "IF" Code "IF" Code Is main gas supply ON? NO Turn on main gas supply & retest Go to section B (next page) On ICB, verify flame Inspect gas YES Is heater's gas YES sensor & gas valve valve in heater valve ON...
Universal H Series Troubleshooting Guide - Page 53

... YES damaged/ wrong? 12. NO Contact tech support: (908) 355-7995 53 NO Inspect and/or clean burner tubes & orifices Replace with new burner kit: FDXLBRN1930 OR Gas Valve (includes orifices): (pg. 20) YES Are burner tubes & orifices damaged? Service LED ON: "IF" Code Section B (continued from previous page) Is correct flame YES sensor installed OR damaged?
Universal H Series Troubleshooting Guide - Page 58

Service LED ON: "AO" Code "AO" Code Replace blower vacuum switch: FDXLBVS1930 Is blower YES damaged? NO Replace blower: Please refer to (pg. 20) Go to (pg. 20) Is vacuum tube YES damaged? 14. NO Replace blower: Please refer to section B NO Install correct plug and replace fuse Replace blower vacuum switch: FDXLBVS1930 Replace ICB: FDXLICB1930 58 Replace vacuum tubing: ...
UHS Heater - How To Guide - Page 7

Cut the wire tie inside the heater as you lower the exchanger back into the heater cabinet. Step 12 Lift and rotate the heat exchanger to the left side of the heater to not damage the insulation as shown. How To: Rotate UHS Heat Exchanger (cont.) Step 9 Step 10 Remove the Thermistor connection from ignition board. Route the RED...

Hayward H400FDP Reviews

Do you have an experience with the Hayward H400FDP that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hayward yet.

Popular Hayward H400FDP Search Terms

The following terms are frequently used to search for Hayward H400FDP support:

Ask a New Question
Use the box below to post a new question about Hayward H400FDP.
Manuals / Documents
Download any of our Hayward H400FDP manuals for free!

We have the following 3 documents available for the Hayward H400FDP:
  • Universal H Series Troubleshooting Guide
  • UHS Heater - How To Guide
  • Energy Guide Label

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward H400FDP manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward H400FDP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.