Get support for Hayward Aqua Plus Controls plus Chlorination

Hayward Aqua Plus Controls plus Chlorination Support Question

Hayward Aqua Plus Controls plus Chlorination Support Question

Find answers below for this question about Hayward Aqua Plus Controls plus Chlorination.
Need a Hayward Aqua Plus Controls plus Chlorination manual? We have 4 online manuals for this item!
Question posted by JSPlato on August 5th, 2011

Aqua Plus Chlorination With External Pump Control

Apparently I bought (online)much more than I needed with the Aqua Plus Automation and Chlorination. All I wanted was the salt chlorination but see the Aq Plus can do much more. I have the old fashioned timers on my pool filter pump and the Polaris booster pump. Initially I palnned to leave those as they are and set up th Aq+ just to chlorinate. Later when I buy a new VS pump I'll rewire everything and get the most from the Aq+ system. I have control power in, T-15 cell , flow switch with proper flow direction, air and water temperature sensors all plugged into the mainboard. Date and time set OK, default menu only displays , date/time, air temp, pool temp, I see no salt level display with filter button "on" or "off", no pool temp reading with filter button "off". I thought I could either program the Aq+ chlorination to be "on" within the time interval that my pool pump is running (under the control of the old switches), or just set it to chlorinate 24 hours, but it would only actually work when the pump was on (flow switch control). There are no chlorination options in the Settings menu, just day, time, light, beep. Questions: 1. Can I set up Aq+ clorination with my pump controlled by an external switch? 2. If I need to change the configuration, how do I unlock the Config menu? Should I? 3. What changes need to be made in Config? 4. Other possible causes for chlorination apparently not working?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward Aqua Plus Controls plus Chlorination Manual Pages

Model: PL-PLUS Installation - Page 1

Wizard pool/spa filter heater1 solar external input active state lights aux1 aux2 valve3 6 button spa side remote remote menus 7-day or weekend/weekday timeclock 12 hour or 24 hour time format ºF or ºC vsp speed (% or rpm) reset to default denotes conditional items 092359D RevF Copyright © 2010 Hayward Aqua Plus® Automation and Chlorination Installation Manual...
Model: PL-PLUS Installation - Page 7

... flowing), when the pool/spa suction return valves are controlled by commands sent to start a Super Chlorinate cycle when the Aux button is pressed and then will turn on the aux relay to circulate the water. If "VSP" is selected, the Aux relay is not available for proper operation. Aux1 External Input Interlock is used...
Model: PL-PLUS Installation - Page 8

... the pump that has been selected in any position other than "pool only", or for use the Aqua Plus to the Aqua dispense the Plus. NOTE: The configuration parameters for plumbing and wiring instructions. Swimmers may become entrapped underneath the cover. The Control Center is important not to be installed at all chips and burrs. 2. Chlorination Function The Aqua Plus...
Model: PL-PLUS Installation - Page 11

... FEATURE VALVE WATER FEATURE PUMP SPA JET PUMP SPA POP-UP IN-FLOOR CLEANER SKIM SUCTION CLEANER MAIN DRAIN ENERGY SAVER PRESSURE CLEANER SPILLOVER POOL OVERFLOW POP-UP POP-UP POP-UP RETURN JET VALVE WATER FEATURE PUMP WATER FEATURE NON-BOOST PRESSURE CLEANER PRESSURE CLEANER Some important notes regarding the Aqua Plus control of the pool. The air sensor...
Model: PL-PLUS Installation - Page 12

... specific information regarding the control logic for 2-speed or variable speed pump operation. Refer to plumbing diagram below ), the Aqua Plus will turn off for a watertight seal. Refer to the appropriate sections in the Pool/Spa sub-menu, the valves will also alternate between the pool and spa every 30 minutes and the filter pump will run at during...
Model: PL-PLUS Installation - Page 13

... any wiring -Follow all the time the pool is being filtered and/or the super chlorinate is "Enabled" and "Pool and Spa", the homeowner will automatically switch the pool/spa suction and return valves to be made to pumps, lights, etc., as well as providing direct input power to the Aqua Plus control relays or circuit breakers. Grounding and Bonding...
Model: PL-PLUS Installation - Page 15

... off , the relay will supply input power to the VSP pump control and be only 1 "primary" unit. Units using version 4.00 or later have both speeds. ! SPST External Switch (either Normally Open or Normally Closed) Hayward Aqua Rite Chlorinator The Aqua Plus can be connected to the Aqua Plus as "secondary". Refer to the wiring diagrams below AND to...
Model: PL-PLUS Installation - Page 16

...Kit Plug in the Aqua Plus control unit. Turbo Cell Only applicable if the chlorinator function is given, ... with solar heating, Hayward offers the AQ-SOL-KIT-xx solar kit that the...Aqua Plus Control Center at the position shown in order to the pool/ spa suction (Valve2) and return (Valve1) valves. Valve3 is enabled. The Aqua Plus does NOT control the power going to an external control...
Model: PL-PLUS Operation - Page 4

... Overview The Hayward Aqua Plus is a multifunction pool controller used to fully manage your pool/spa. if EcoStar VSPs are available. No function Move to previous/next menu item This display will continuously recycle, virtually eliminating the need to add more remote display/keypads. Automation The Aqua Plus can control pumps, valves, lighting, heaters, and chlorination. The delay time...
Model: PL-PLUS Operation - Page 6

... of the Aqua Plus is to automate the operation of heater cooldown operation. Note that if you turn a relay on manually, it off manually, or the next time the programmed automatic operation would normally turn off the filter pump. Display Heater Indicator Valve 3 Indicator Check System Indicator Service Button (main display only) Salt Level 3200ppm...
Model: PL-PLUS Operation - Page 7

... filter pump will switch the Aqua Plus to normal operation after 3 hours. If you want to completely disable the automatic operation and operate the system manually, you when the Aqua Plus detects any problems that may occur in your pool and/ or spa system. Check System Indicator The "CHECK SYSTEM" LED will switch back to inspect theAqua Plus chlorinator cell...
Model: PL-PLUS Operation - Page 9

... temperature air temperature chlorinator setting salt level reason pump is running (not scheduled) inspect cell reason hi-speed is running (not scheduled) countdown time remaining heater control status system manual off check system error filter vsp speed/reason lights/aux speed/reason pH/ORP levels spa heater1 temperature pool heater1 temperature spa solar temperature pool solar temperature vsp...
Model: PL-PLUS Operation - Page 18

... Aqua Plus will turn the output off while the valves are controlled by commands sent to run at . Timeclock - Aux1 Pump Speed This is the speed of operation anytime the pump has been off . If "Pool and Spa" is allowed to a Hayward Variable Speed Pump (VSP). Interlock is on and off for low speed filter pump, dimmer, group, super chlorinate...
Model: PL-PLUS Operation - Page 19

... the relay type is the minimum speed the pump will have precedence over freeze protection. WARNING: Do not use the Aqua Plus to previous/next configuration menu ! If applicable, the homeowner will be prompted to enter separate "pool" and "spa" settings. On, off , first 3 minutes of the pool/spa suction valves, the proper temperature setting will be...
Model: PL-PLUS Operation - Page 20

... control logic is "Enabled", several additional steps must be allowed during solar heating except for the first 3 minutes after a programmed time (see Timers Menu in the "Solar Config." the Aqua Plus... enabled and "2-speed Filter" is enabled, low speed pump operation will be used to control other pool devices that only one of the external input device when active. 17 Lights Config. + to...
Model: PL-PLUS-16V Installation - Page 1

... chlorinator setting salt level reason pump is running (not scheduled) inspect cell reason hi-speed is running (not scheduled) countdown time remaining heater control status system manual off check system error group active filter vsp speed/reason spa filter vsp speed/reason lights/aux speed/reason pH/ORP levels spa heater1 temperature pool heater1 temperature spa heater2 temperature pool...
Model: PL-PLUS-16V Installation - Page 8

... to "spa only" or "spillover" operation. Do not mount the Aqua Plus 16v inside the box), it will be forced off whenever the filter pump is on and add salt directly into the pool. Note that has been selected in swimming pools". Always check stabilizer (cyanuric acid), when checking salt. POUNDS and (Kg) OF STABILIZER (CYANURIC ACID) NEEDED FOR...
Model: PL-PLUS-16V Installation - Page 10

... damage. If in the Aqua Plus 16v Operation Manual and the owner's manual of the pump that the internal cams in and around the pool/spa area. AQL2-SS-RF, AQL2-POD The AQL2-SS-RF and AQL2-POD are waterproof portable remote controls that can be forced off when the external input is intended to mount...
Model: PL-PLUS-16V Installation - Page 13

... running . 10 NOTE: The configuration parameters for all Aux outputs are controlled by commands sent to the heater(s) and will be changed . Otherwise, the Aqua Plus 16v will only chlorinate the pool and the spa sanitization will display the spa temperature whenever the "Spa Filter" pump is renamed "Pool Filter" and can be initiated (Manual On/Off, Countdown Timer, or...
Model: PL-PLUS-16V Operation - Page 8

... Low - Pressing the "HEATER" button causes the Aqua Plus 16v to switch the heater control output between 50ºF and 140ºF, and the salt level must be between a "forced off while the pool/spa valves are OK, the timeout may need to normal operation after you check the chlorinator operation in order to Heater2 when Heater2 is...

Similar Questions

Leaking Hayward Ec40 Pool Filter
My filter is leaking from where we clamp to seal closed. We checked fingers, rubber seal and clamps ...
(Posted by Mare101670 1 year ago)
Can't Unlock The Configuration Menu On The Aql Plus 20 Controller
When I press the left and right arrows simultaneously for greater than 5 seconds the configuration m...
(Posted by Jjvarone 10 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Aqua Plus Controls plus Chlorination manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.