Model: ALL MODELS Installation
Page 1
Hayward ECOMMAND 4 Automation Installation Manual for models HPC-4 HPC-4-ACT HPC-4-RC HPC-4-ACT-RC www.haywardnet.com
Hayward ECOMMAND 4 Automation Installation Manual for models HPC-4 HPC-4-ACT HPC-4-RC HPC-4-ACT-RC www.haywardnet.com
Model: ALL MODELS Installation
Page 4
...ECOMMAND 4 Electronics Unit (3) Temperature sensors with 15 ft. (5m) cable, hose clamp (2) Goldline GVA-24 actuators (HPC-4-ACT, HPC-4-ACT-RC only) (1) Goldline AQL2-BASE-RF/AQL2-SS-RF remote control (HPC-4-RC, HPC-4-ACT-RC only) What's NOT Included Some of the additional items that you may need to complete an installation include: Circuit breakers... filter pump and other high voltage loads Wire for bonding Miscellaneous Mounting hardware (screws, etc.) for mounting ECOMMAND 4 Valves (use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators Accessory Products -
...ECOMMAND 4 Electronics Unit (3) Temperature sensors with 15 ft. (5m) cable, hose clamp (2) Goldline GVA-24 actuators (HPC-4-ACT, HPC-4-ACT-RC only) (1) Goldline AQL2-BASE-RF/AQL2-SS-RF remote control (HPC-4-RC, HPC-4-ACT-RC only) What's NOT Included Some of the additional items that you may need to complete an installation include: Circuit breakers... filter pump and other high voltage loads Wire for bonding Miscellaneous Mounting hardware (screws, etc.) for mounting ECOMMAND 4 Valves (use standard Hayward, Pentair/Compool, or Jandy valves) Additional valve actuators Accessory Products -
Model: ALL MODELS Installation
Page 5
...the knockouts facing downward. This information can be installed at all times for outdoor mounting. Because the enclosure also acts as the collectors. Drill a 3/8" (10mm) diameter hole in the filtration plumbing after the filter but before ...and gently tighten until O-ring collar sits flush on a flat surface with AQL2-SS-RF wireless remote control only. ACT-RC) The ECOMMAND 4 is installed in the PVC piping and remove all 15 ft. (5m) long. The control...the temperature sensors, and valve actuators (if applicable) are included with HPC-4-RC, HPC-4- If in the Settings Menu.
...the knockouts facing downward. This information can be installed at all times for outdoor mounting. Because the enclosure also acts as the collectors. Drill a 3/8" (10mm) diameter hole in the filtration plumbing after the filter but before ...and gently tighten until O-ring collar sits flush on a flat surface with AQL2-SS-RF wireless remote control only. ACT-RC) The ECOMMAND 4 is installed in the PVC piping and remove all 15 ft. (5m) long. The control...the temperature sensors, and valve actuators (if applicable) are included with HPC-4-RC, HPC-4- If in the Settings Menu.
Model: ALL MODELS Installation
Page 6
... valve and the desired valve action. RETURN SUCTION OUT OUT IN IN (ComINmon) OUT (Common) 3 Optional Valve Actuators (included with HPC-4-ACT, HPC-4-ACT-RC) For optional actuators used . Optional Base Station (included with HPC-4-RC, HPC-4-ACT-RC) The AQL2-BASE-RF optional base station must be adjusted depending on the way the actuator is used with the ECOMMAND...
... valve and the desired valve action. RETURN SUCTION OUT OUT IN IN (ComINmon) OUT (Common) 3 Optional Valve Actuators (included with HPC-4-ACT, HPC-4-ACT-RC) For optional actuators used . Optional Base Station (included with HPC-4-RC, HPC-4-ACT-RC) The AQL2-BASE-RF optional base station must be adjusted depending on the way the actuator is used with the ECOMMAND...