User Manual
Page 3
... installation of drain hose A more than 2m. 1 Accessory parts Number of articles 1 Remote controller 1 2 R-03 dry battery 2 more than 5cm The models adopt HFC free refrigerant R410A 3 1 Mounting plate 4 1 Drain hose 5 4X25 Screw Plastic cap 4 6 Drain-elbow 1 7 Cushion 4 8 1 Pipe supporting plate more than10 cm Attention must be more than 10 cm...
... installation of drain hose A more than 2m. 1 Accessory parts Number of articles 1 Remote controller 1 2 R-03 dry battery 2 more than 5cm The models adopt HFC free refrigerant R410A 3 1 Mounting plate 4 1 Drain hose 5 4X25 Screw Plastic cap 4 6 Drain-elbow 1 7 Cushion 4 8 1 Pipe supporting plate more than10 cm Attention must be more than 10 cm...
User Manual
Page 8
... bending radius should be conducted by professional air conditioner engineer. Connecting the pipe of sands, etc. The connection pipe is over 7m, the function of refrigerant must be charged, according to 40 mm or longer. shall not enter the pipe. If it as figure. (Note: Only for heat pump unit.) 6 If... the pipe has to be lengthened, the refrigerant should be 30 to 20 g/m. But the charge of the unit will be affected. Insert the cable according to terminal number in the same manner...
... bending radius should be conducted by professional air conditioner engineer. Connecting the pipe of sands, etc. The connection pipe is over 7m, the function of refrigerant must be charged, according to 40 mm or longer. shall not enter the pipe. If it as figure. (Note: Only for heat pump unit.) 6 If... the pipe has to be lengthened, the refrigerant should be 30 to 20 g/m. But the charge of the unit will be affected. Insert the cable according to terminal number in the same manner...
User Manual
Page 9
... 9.52mm(3/8") 12.7mm(1/2") 3-way valve If it does not stop the operation of pipe connection. Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. 2-way valve 3-way valve Service port cap Valve rod cap Valve... and 3-way's, connect the service port into the projection of the air conditioner leaks, it is necessary to discharge all the refrigerant. CAUTION: 1.If the refrigerant of charge hose (low) for gaugemanifold. If the scale-moves of charge hose (center) for gaugemanifold into the cooling circulation system...
... 9.52mm(3/8") 12.7mm(1/2") 3-way valve If it does not stop the operation of pipe connection. Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. 2-way valve 3-way valve Service port cap Valve rod cap Valve... and 3-way's, connect the service port into the projection of the air conditioner leaks, it is necessary to discharge all the refrigerant. CAUTION: 1.If the refrigerant of charge hose (low) for gaugemanifold. If the scale-moves of charge hose (center) for gaugemanifold into the cooling circulation system...