User Manual
Page 1
Mobile Air Conditioner HM-07CO3 AM052ACNBA HM-09OA03 (HM-05CB03/R1) HM-07CO3/R1 Operation Manual Contents • Outline • Description of the components 3 • Usage 6 • Maintenance 9 • Preservation 10 • Check on troubles by self 11 • Points of attention 12 • Operating principle 13 • Installation of the accessories 13 • Please read this manual carefully before use. • Please keep it attentively. No.7465602 I
Mobile Air Conditioner HM-07CO3 AM052ACNBA HM-09OA03 (HM-05CB03/R1) HM-07CO3/R1 Operation Manual Contents • Outline • Description of the components 3 • Usage 6 • Maintenance 9 • Preservation 10 • Check on troubles by self 11 • Points of attention 12 • Operating principle 13 • Installation of the accessories 13 • Please read this manual carefully before use. • Please keep it attentively. No.7465602 I
User Manual
Page 2
In using the cooling function,please install the hot air exhaust duct as packaged air conditioner offering partial cooling function,instead of reducing the temperature of the whole room significantly. Remark per EMC Directive 89/336/EEC To prevent flicker impression during the start of the compressor(Technical Process) following installation conditions do apply for family and office usage,especially family Exhaust duct Cold air with the functions like...
In using the cooling function,please install the hot air exhaust duct as packaged air conditioner offering partial cooling function,instead of reducing the temperature of the whole room significantly. Remark per EMC Directive 89/336/EEC To prevent flicker impression during the start of the compressor(Technical Process) following installation conditions do apply for family and office usage,especially family Exhaust duct Cold air with the functions like...
User Manual
Page 3
Rooms with good heat-insulation structure. There' s ideal cooling effect in the Hot air whole area in front of the blowing wind(Fig.1) 2. If the area of T.3.15A/250V. 6.Not intended to be used in the following ...cold air 3.Applicable temperature range: max: D.B.T. 35°C W.B.T. 30°C min: D.B.T. 18°C W.B.T. 14°C 4.The wiring method should be in line with the local wiring standard. 5.If the fuse is broken or power cable damaged it should be replaced by the qualified person.lf the fuse on PC board is broken, please change it with the type of the room is adaptive...
Rooms with good heat-insulation structure. There' s ideal cooling effect in the Hot air whole area in front of the blowing wind(Fig.1) 2. If the area of T.3.15A/250V. 6.Not intended to be used in the following ...cold air 3.Applicable temperature range: max: D.B.T. 35°C W.B.T. 30°C min: D.B.T. 18°C W.B.T. 14°C 4.The wiring method should be in line with the local wiring standard. 5.If the fuse is broken or power cable damaged it should be replaced by the qualified person.lf the fuse on PC board is broken, please change it with the type of the room is adaptive...
User Manual
Page 4
Description of the components Machine body Front LCD Control panel Vertical pendulum blade Gaster wheel Back Hot air exhaust duct Handle buckle 0 Power plug Water tank Accessories of hot air exhaust duct Hot air exhaust exit 111 Top air intake bar Water exit • Use to connect the drainage • Do not pull out this part when the drainage is not used or it may result in leakage of water Low air intake bar -3-
Description of the components Machine body Front LCD Control panel Vertical pendulum blade Gaster wheel Back Hot air exhaust duct Handle buckle 0 Power plug Water tank Accessories of hot air exhaust duct Hot air exhaust exit 111 Top air intake bar Water exit • Use to connect the drainage • Do not pull out this part when the drainage is not used or it may result in leakage of water Low air intake bar -3-
User Manual
Page 5
Description of the components Control panel Water full indicator Fan selection key The running indicator of the compressor Running mode key 0 WATER FULL 0 OPERATION MODE FAN SPEED LOUVER Sweeping key Temperature setting key TEMP SET SLEEP 1/0 ON/OFF TIME SET Time setting key LCD window Sleep setting key Power switch key Displaying of sleeping Displaying of automatic sweeping Displaying of Displaying of Cooling dehumidifying Fan mode Displaying of the fan speed
Description of the components Control panel Water full indicator Fan selection key The running indicator of the compressor Running mode key 0 WATER FULL 0 OPERATION MODE FAN SPEED LOUVER Sweeping key Temperature setting key TEMP SET SLEEP 1/0 ON/OFF TIME SET Time setting key LCD window Sleep setting key Power switch key Displaying of sleeping Displaying of automatic sweeping Displaying of Displaying of Cooling dehumidifying Fan mode Displaying of the fan speed
User Manual
Page 6
... will flash,and alarm with beep.The compressor stops working.The air conditioner enters fan mode.Please take out the water tank,pour the condensed water,then replace it.The air conditioner runs as per the mode before stopping of the compressor(the compressor can only start after 3 minutes of timedelay protection). 9.The run indicator of the compressor: In cooling or dehumidifying mode,the indicator will be on in the running mode:cooling LCD window displays...
... will flash,and alarm with beep.The compressor stops working.The air conditioner enters fan mode.Please take out the water tank,pour the condensed water,then replace it.The air conditioner runs as per the mode before stopping of the compressor(the compressor can only start after 3 minutes of timedelay protection). 9.The run indicator of the compressor: In cooling or dehumidifying mode,the indicator will be on in the running mode:cooling LCD window displays...
User Manual
Page 7
...,Middle,Low. the indoor temperature will rise a little. 1) Confirm that the water tank is well placed. 6 • 2) Press Running Mode key to select dehumidifying mode.The LCD window displays The machine runs under the sunlight,please shelter with the wall or other heat sources in the room as far as dehumidifying device the hot air exhaust duct is not needed. 3.Fan running: 1) Press the...
...,Middle,Low. the indoor temperature will rise a little. 1) Confirm that the water tank is well placed. 6 • 2) Press Running Mode key to select dehumidifying mode.The LCD window displays The machine runs under the sunlight,please shelter with the wall or other heat sources in the room as far as dehumidifying device the hot air exhaust duct is not needed. 3.Fan running: 1) Press the...
User Manual
Page 8
... water inside the position where the tank is placed.It is used . 8.Method of consecutive drainage 1) Take out the drain hose. The air conditioner runs under Cooling or Dehumidifying mode,or the machine will give eight beeping.At the same time the compress or stops working,and the complete appliance blows at the former set fan speed.After 3 minutes the complete appliance stops working mode to Fan mode. \.- (2) If you drain...
... water inside the position where the tank is placed.It is used . 8.Method of consecutive drainage 1) Take out the drain hose. The air conditioner runs under Cooling or Dehumidifying mode,or the machine will give eight beeping.At the same time the compress or stops working,and the complete appliance blows at the former set fan speed.After 3 minutes the complete appliance stops working mode to Fan mode. \.- (2) If you drain...
User Manual
Page 9
... hose into the drain mouth.Please insert the root reliably. 4) Drainage: • During drainage,especially there are children nearby,please do not add force on the drain groove. • Do not bend the hose. Usage 3) Hold the drain groove,and plug the top of the smoke smell and odor,and filter the dust in the air. (1) Filter bar (2) Active carbon screen: use...
... hose into the drain mouth.Please insert the root reliably. 4) Drainage: • During drainage,especially there are children nearby,please do not add force on the drain groove. • Do not bend the hose. Usage 3) Hold the drain groove,and plug the top of the smoke smell and odor,and filter the dust in the air. (1) Filter bar (2) Active carbon screen: use...
User Manual
Page 10
... detergent to clean it,then dry it should be performed after the machine stops running, that is to say,the power is switched off,so as to avoid accidents of corresponding clamp hole.Push the handle to positioning. Install the air screen and filter bar Fix the active carbon air screen at the position of electric shock. In cleaning do not use solvent...
... detergent to clean it,then dry it should be performed after the machine stops running, that is to say,the power is switched off,so as to avoid accidents of corresponding clamp hole.Push the handle to positioning. Install the air screen and filter bar Fix the active carbon air screen at the position of electric shock. In cleaning do not use solvent...
User Manual
Page 11
... result in troubles. 1.Pour the water in Fan mode. 2.Bind the power line with the line tying at the back. 3.Cover the machine with water or likely to touch water,so as to avoid changing color. Do not use it at places soaked with rubber bag,and keep it at dry ventilating places. 4.Do not put the machine horizontally. / Drain hose Lid -10...
... result in troubles. 1.Pour the water in Fan mode. 2.Bind the power line with the line tying at the back. 3.Cover the machine with water or likely to touch water,so as to avoid changing color. Do not use it at places soaked with rubber bag,and keep it at dry ventilating places. 4.Do not put the machine horizontally. / Drain hose Lid -10...
User Manual
Page 12
... for repair or service.If the trouble is too low Is the filter screen blocked with Please clean the filte screen dust? (refer to P8) Is there barrier at the wind gap? Set to cool,but cannot start running ...Water Full indicator light up . mode,but find no cold air(the LCD wind- It will start running indicator of temperature,not abnormal phenomenon. -11- Is the filter screen too dirty? Please insert the power plug into the outlet reliably? It is normal phenomenon. The noise and vibration in Is the machine used in running are too hot too loose? The LCD window displays...
... for repair or service.If the trouble is too low Is the filter screen blocked with Please clean the filte screen dust? (refer to P8) Is there barrier at the wind gap? Set to cool,but cannot start running ...Water Full indicator light up . mode,but find no cold air(the LCD wind- It will start running indicator of temperature,not abnormal phenomenon. -11- Is the filter screen too dirty? Please insert the power plug into the outlet reliably? It is normal phenomenon. The noise and vibration in Is the machine used in running are too hot too loose? The LCD window displays...
User Manual
Page 13
... check it. 2) Please hold the plug tightly to pull it out.If you meet the problem,please first pull off the power plug,and pour out the water in the tank. • Do not make the product slanting or overturn.If you pull the wire,it may result in deformation or cracks...electric shock. • Before moving the air conditioner please first pull off the power plug,and send it to the sales department on checking and repairing. • Please do not spray it with cloth,or it may result in breakdown and deformation. • Please do not let the air exit adhere to wall,or cover the air...
... check it. 2) Please hold the plug tightly to pull it out.If you meet the problem,please first pull off the power plug,and pour out the water in the tank. • Do not make the product slanting or overturn.If you pull the wire,it may result in deformation or cracks...electric shock. • Before moving the air conditioner please first pull off the power plug,and send it to the sales department on checking and repairing. • Please do not spray it with cloth,or it may result in breakdown and deformation. • Please do not let the air exit adhere to wall,or cover the air...
User Manual
Page 14
..., it enters the condenser,and performs heat exchange with the indoor air so as to reduce the relative humidity of the indoor air.The cycle is lower than the dew- Window Drainpipe Accessory of the front air exit. 2.Dehumidifying cycle: After the power is switched on,the Fan 1 Fan 1 Motor 1 1 Heat exchanger and 2 and the compressor start running ,The low-temperature low-pressure refrigerant vapor Cold air Current 1 in the...
..., it enters the condenser,and performs heat exchange with the indoor air so as to reduce the relative humidity of the indoor air.The cycle is lower than the dew- Window Drainpipe Accessory of the front air exit. 2.Dehumidifying cycle: After the power is switched on,the Fan 1 Fan 1 Motor 1 1 Heat exchanger and 2 and the compressor start running ,The low-temperature low-pressure refrigerant vapor Cold air Current 1 in the...
User Manual
Page 15
No.7465602 Mobile Air Conditioner Operation Manual HM-07C03 HM-09CA03 HM-07C03/R1 Contents Outline 1 Description of the components 3 Usage 6 Maintenance 9 Preservation 10 Check on troubles by self 11 Points of attention 12 Operating principle 13 Installation of the accessories 13 • Please read this manual carefully before use. • Please keep it attentively.
No.7465602 Mobile Air Conditioner Operation Manual HM-07C03 HM-09CA03 HM-07C03/R1 Contents Outline 1 Description of the components 3 Usage 6 Maintenance 9 Preservation 10 Check on troubles by self 11 Points of attention 12 Operating principle 13 Installation of the accessories 13 • Please read this manual carefully before use. • Please keep it attentively.