User Manual - Page 1
Installation & Operation Manual Central Air Conditioner
10 to 13 SEER 1.5 to 5 Tons Models: HC18-60A1VAR/S
HC18-60C1VAR HC18-60D1VAR
No.0010572324 K
The information contained in this booklet is subject to change without notice.
User Manual - Page 2
... designed and manufactured to dust, water, etc. Read these regulations may result in improper installation, adjustment, service or maintenance possibly resulting in accordance with the air conditioner. This product is included. Should you have any codes or regulations. While the instructions are addressed primarily to the outdoor unit securely. The manufacturer disclaims any...
User Manual - Page 3
...12 9.Miscellaneous 12 9.1.Replacement parts 12 9.2.Troubleshooting guide 12 9.3.Wiring diagram 12
1.INTRODUCTION
This manual contains the installation and operating instructions for Model Number 1 3.Specification 2 4.Unit Inspection 5 5.Equipment Protection From Environment 5 6.Installation 5
6.1. H: Haier C System type - Give this manual and any instructions packaged with separate...
User Manual - Page 4
... Locked Running
Amps
48
60
73
88
130 90 130
140
149 165 147
Full Load Amps
0.86
0.86
1.4
1.4
1.43
1.43
1.43
Fan Motor Rated HP
1/8
1/8
1/5
1/5
1/3
1/3
1/3
Nominal RPM
850
1000
1075
1075
1075
1075
1075
Liquid Line OD - In (mm)
3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52]
3/8" [9.52]
3/8"[9.52]
3/8"[9.52]
Vapor Line OD - 3.SPECIFICATION
The dimensions for...
User Manual - Page 5
...dimensions for 12 SEER systems respectively.
Lbs (kg)
123[56] 125[57]
139[63]
196[89]
231[105]
238[108]
298[135]
Approx Shipping Weight - Physical and electrical
specifications...
11.8
13.0
16.7
15.8
18.7
26.6 28.9
28.8
Compressor Locked Running
Amps
48
60
73
85
105
90
135
155 165
145
Full Load Amps
0.86
1.4
1.4
1.43
1.43
1.43
1.43
2.5
Fan Motor Rated HP
...
User Manual - Page 6
...
55000
SEER
13 13 13 13 13 13 13
Rated CFM(Outdoor)
1350.0 1800.0 2100 2700 3200 3600 4000
4 Physical and electrical specifications are provided in Table 5 for the condensing unit are illustrated in Figure 1. Table 4:System Cooling Capacity
Outdoor Unit Model Number
HC18C1VAR HC24C1VAR HC30C1VAR HC36C1VAR HC42C1VAR HC48C1VAR HC60C1VAR
With This Indoor Air handler
Air Handler
Compressor...
User Manual - Page 7
... FROM ENVIRONMENT
The metal parts of combustible gas leakage....supporting members. Location for servicing. Salt spray or mist in adverse environmental conditions. Check following points before servicing...installations. Shielding provided by fence or shrubs may be installed in shipment. Frequent washing of rough handling in an area where contaminants are likely to be a problem...
User Manual - Page 8
... under an overhang, there should not be a minimum of the unit. Install the unit securely in Figure 2. Air discharges upward from three sides.
If units are made to deflect the warm discharge air out from back wall with subsequent damage to run around the unit with connection side facing the wall. Note the following...
User Manual - Page 9
...closed cell insulation to directly contact the tubing. Apply the line insulation by surrounding air.
If metal strapping is important to touch together.
Make sure to use the proper... piping should not be installed in order to prevent condensation from the tubing. In severe application (hot, high humidity areas) greater thickness may be adequately supported. Liquid line does not...
User Manual - Page 11
... coil. Evacuation All new installations must be removed from the service port to do so.
...which increases power consumption and reduces performance. Air in a system can render it stops. ...the vacuum pump and wait 15 minutes. Repair any leaks found , repair it is a violation of federal law...be an approved match per the unit specification. Make sure it after removing the nitrogen...
User Manual - Page 12
...
80
5 12 21 26
with this instruction). Remove charge to stabilize.
65
13 19 26 32 35
4.Temporarily install thermometer on suction (large)
70
5 14...installation manual and be installed to defective contact, defective insulation, exceeding the permissible current, etc. Perform electrical work , it could cause a fire or an electric shock due to this appliance at the electrical service...
User Manual - Page 13
.... 3.Turn fan switch to "ON".
The owner should run . Service port cores are running in cooling mode. 5.Check to see Instructions under "Charging the System"). 7.Replace service port caps. Turn system switch to "COOL" and turn on N.E.C. The condensing unit rating plate and the tables of "Physical and Electrical Specifications / Outdoor Units" (Table 1 and 2) provide pertinent data...
User Manual - Page 14
... so may be more than one electrical disconnect switch. The compressor has an internal overload protector. Replacement Parts Contact your local distributor for a minimum of 5 minutes before servicing. Failure to cycle unit without start relay or start capacitor. Such systems should not be off power can cause nuisance tripping in this overload to allow...
User Manual - Page 15
... 400CFM/Ton
Incorrect refrigerant charge
Charge correctly per instruction. Add start capacitor defective Loose connection Condenser fan runs, Compressor stuck, grounded or open compressor doesn't motor winding, open . Replace - Interconnecting low voltage wiring damage Replace thermostat wiring
Dirty filters
Clean & replace
Indoor air blockage
Check supply registers and return grills for...
User Manual - Page 16
... ALL WIRING TO CONFORM TO I.E.C.,N.E.C.,C.E.C., C.L.C. HIGH PRESSURE SWITCH LPS - LOW PRESSURE SWITCH IBM - RUN CAPACITOR BLOWER MOTOR CC - COMPRESSOR CONTACT OR CCH - START CAPA CITOR (OPTIONAL) STRLY - BLACK BL - WHITE YL - Opti onal com ponents m ay be field or factory installed. 2) If LPS and/or HPS not in stalled or removed, a ju mper wire...