Haier HSU-09LEK13 Support and Manuals
Get Help and Manuals for this Haier item
This item is in your list!
View All Support Options Below
Free Haier HSU-09LEK13 manuals!
Problems with Haier HSU-09LEK13?
Ask a Question
Free Haier HSU-09LEK13 manuals!
Problems with Haier HSU-09LEK13?
Ask a Question
Popular Haier HSU-09LEK13 Manual Pages
User Manual - Page 1
...
4
10
1
Pipe supporting plate
11
Connecting cable 1
Arrangement of drain hose
A
more than 10cm
C
more than 10cm
D E
No.0010518787
more than 60cm
more than 15cm
The marks from A to G in the figure are the parts numbers.
The distance between the indoor unit and the floor should be paid to this manual. Installation Manual of indoor...
User Manual - Page 2
...supporter... 12 6.35mm(1/4") 12.7mm...Install an exclusive branch circuit of the unit are not disturbed. Do not extend the cable by rain or direct sunlight and is the same as illustrated in the room are not increased. Indoor Unit
Selection of earthquake and strong wind. Use optional parts for piping set...HSU-09LEK13 HSU-12LEK13 HSU-07LEK03 HSU-07HEK03
HSU-09LEK03 HSU-12LEK03 HSU-09HEK03 HSU...
User Manual - Page 3
... side Wall hole 60mm
Outdoor side
Thickness of wall
(Section of wall hole) G Piping hole pipe
3.Installation of the Indoor Unit Drawing of pipe
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left Left-rear ...
User Manual - Page 4
....
[Other direction piping]
Cut away, with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Lid for right piping ...plate.
Indoor unit
1. Move the body from side to side to the position of connecting part specially.
In order to leave agraffe,then lift the bottom of indoor unit, and pull it...
User Manual - Page 5
... After installation, the power plug should be incorporated into terminal block, then tighten the screws. A breaker should be not less than 3mm.
1( ) L ) N (3 42
1 L) 2( N) (
Indoor unit
Outdoor unit
HSU-07LEK03 HSU-09LEK03 HSU-12LEK03
HSU-09LEK13 HSU-12LEK13
connecting wiring: -mod 07-12: 3G1.0mm
Power cable: -mod 07-12: 3G1.0mm
Indoor unit
Outdoor unit
HSU-07HEK03 HSU-09HEK03
HSU...
User Manual - Page 6
Outdoor unit
Outdoor unit
1.Installation of Outdoor Unit
Install according to Drawing for heat pump unit.)
6 Pipe Diameter ( ) Fastening torque
Liquid side 6.35mm(1/4") Gas side 9.52mm(3/8") Gas side 12.7mm(1/2")
18N.m 42N.m 50N.m
Be careful that matters, such as the indoor unit. Insert the cable according to crush the pipe Connecting the pipe of...
User Manual - Page 7
...: When extending piping, air inside piping shall be installed every 5~7m.
Piping length
for first installation, this procedure, 50g refrigerant will be discharged in ...
2-way valve 6.35mm(1/4") 6.35mm(1/4")
3-way valve 9.52mm(3/8") 12.70mm(1/2")
HSU-07LEK03 HSU-09LEK03 HSU-12LEK03 HSU-09LEK13 HSU-12LEK13 HSU-07HEK03 HSU-09HEK03 HSU-12HEK03
Indoor unit
A
Outdoor unit
B
A
B
Indoor unit...
User Manual - Page 8
...12.7mm(1/2")
) Size A(mm) 0.8~1.5 1.0~1.8 1.2~2.0
Correct
Incorrect
Lean Damage of flare Crack Partial Too outside
3.On Drainage
Please install... abided by the code? Is there any...installation in a moist place, please install an earth leakage breaker. Is the connecting wiring of pipe connecting? Is the operation of indoor and outdoor firmly inserted to operate through the instruction manual...