Manual
Page 2
GIGA -BYTE TECHNOLOGY CO., LTD. [3] Open Windows IE and connect to target system BMC Web UI for logon to system. [4] Power off the target system [5] Update BIOS (1.) Select Update page (2.) Select Firmware Type to "BIOS & ME" (3.) Select File Path of "image.RBU" (4.) Click Upload button
GIGA -BYTE TECHNOLOGY CO., LTD. [3] Open Windows IE and connect to target system BMC Web UI for logon to system. [4] Power off the target system [5] Update BIOS (1.) Select Update page (2.) Select Firmware Type to "BIOS & ME" (3.) Select File Path of "image.RBU" (4.) Click Upload button
Manual
Page 6
Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. GIGA -BYTE TECHNOLOGY CO., LTD. 2. BMC command format table Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. GIGA -BYTE TECHNOLOGY CO., LTD. 2. BMC command format table Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
Manual
Page 8
Use command 0x06 0x01 to target system BMC through ipmitool. ipmitool -H 10.1.27.150 -U admin -P password raw 0x06 0x01 2.3. Update BIOS (Sample on Windows client PC) [1] Set up TFTP service application Execute Tftpd64.exe Set Current Directory to file path of "image.RBU" GIGA -BYTE TECHNOLOGY CO., LTD. [2] Execute cmd.exe and connect to check connect BMC is success or not. e.g.
Use command 0x06 0x01 to target system BMC through ipmitool. ipmitool -H 10.1.27.150 -U admin -P password raw 0x06 0x01 2.3. Update BIOS (Sample on Windows client PC) [1] Set up TFTP service application Execute Tftpd64.exe Set Current Directory to file path of "image.RBU" GIGA -BYTE TECHNOLOGY CO., LTD. [2] Execute cmd.exe and connect to check connect BMC is success or not. e.g.
Manual
Page 10
... upload status e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available.) e.g. GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application.
... upload status e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available.) e.g. GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application.
Manual
Page 2
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power...
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power...
Manual
Page 5
... LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support...
... LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support...
Manual
Page 6
... required configuration requirements: Supported Browsers: Internet Explorer 8~12 Google chrome Version 29.0.1547.66m Firefox 2.0 JAVA Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to http://www.java.com 2. Choose the folder location. (Save the file to a known location on the saved file icon to replace. 9. Click Download on Agree and Start Free Download 4. Click...
... required configuration requirements: Supported Browsers: Internet Explorer 8~12 Google chrome Version 29.0.1547.66m Firefox 2.0 JAVA Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to http://www.java.com 2. Choose the folder location. (Save the file to a known location on the saved file icon to replace. 9. Click Download on Agree and Start Free Download 4. Click...
Manual
Page 7
Select BMC network Configuration 4. Select Server Management. 3. The BMC IP Address will appear on the IPv4 Address parameter. 6 Define Configuration Address source to enable the console redirection function. 1. Save and Exit. 6. Gigabyte Content Management Network Configuration Please follow the instruction to DynamicBmcDhcp or Static. 5. Go to BIOS setup menu. 2.
Select BMC network Configuration 4. Select Server Management. 3. The BMC IP Address will appear on the IPv4 Address parameter. 6 Define Configuration Address source to enable the console redirection function. 1. Save and Exit. 6. Gigabyte Content Management Network Configuration Please follow the instruction to DynamicBmcDhcp or Static. 5. Go to BIOS setup menu. 2.
Manual
Page 10
... in using your DHCP server. 2. It is Intel C20x series chipset, please enter the following values: Username: admin Password: password If your identified IP. Enter the following values: Username: root Password: superuser The default user name and password are in , you to enter Username and Password. 3. When you have full administrative powers. Gigabyte Content Management System Console Overview 1. Open a web browser and type in your motherboard is...
... in using your DHCP server. 2. It is Intel C20x series chipset, please enter the following values: Username: admin Password: password If your identified IP. Enter the following values: Username: root Password: superuser The default user name and password are in , you to enter Username and Password. 3. When you have full administrative powers. Gigabyte Content Management System Console Overview 1. Open a web browser and type in your motherboard is...
Manual
Page 12
... port. 2. Dedicate Mode When set to Shared Mode, you can configure the BMC related settings through the NIC2 port. (Shared NIC Mode) 3. Failover Mode When set to take effect of changes. 11 Select the Network Mode from the drop-down list. 1. Please note that the changes may not take effect immediately, click "Refresh" to Dedicate Mode, you can view and modify the network settings on this screen. Configuration Network You can configure...
... port. 2. Dedicate Mode When set to Shared Mode, you can configure the BMC related settings through the NIC2 port. (Shared NIC Mode) 3. Failover Mode When set to take effect of changes. 11 Select the Network Mode from the drop-down list. 1. Please note that the changes may not take effect immediately, click "Refresh" to Dedicate Mode, you can view and modify the network settings on this screen. Configuration Network You can configure...
Manual
Page 17
... Console redirection type and to be executed. Once the connection mode is communicating over. 16 An Administrator can change user access privileges. Privilege levels tell the BMC which commands are allowed, except for configuration commands that can even execute configuration commands that would disable the channel that the Administrator is set, select the Baud Rate and Flow Control from a remote location. The following...
... Console redirection type and to be executed. Once the connection mode is communicating over. 16 An Administrator can change user access privileges. Privilege levels tell the BMC which commands are allowed, except for configuration commands that can even execute configuration commands that would disable the channel that the Administrator is set, select the Baud Rate and Flow Control from a remote location. The following...
Manual
Page 18
IPMI Settings IPMI Settings provides remote configuration over LAN. When you finish the configuration, click "Apply Changes". 17 To activate IPMI remote configuration by LAN, check Enable IPMI Over LAN option, define the Channel Privilege Level Limit, and enter the Encryption Key.
IPMI Settings IPMI Settings provides remote configuration over LAN. When you finish the configuration, click "Apply Changes". 17 To activate IPMI remote configuration by LAN, check Enable IPMI Over LAN option, define the Channel Privilege Level Limit, and enter the Encryption Key.
Manual
Page 19
... immediate clock set Requested Mode, or Daemon Mode in place. Select Slew mode when you can modify configuration settings and click the Apply Changes button to execute the settings, as well as click the Sync Time Now button (when in Requested Mode) to adjust the time smoothly over time if there are time sensitive applications in this parameter. Select Step mode to configure the Network...
... immediate clock set Requested Mode, or Daemon Mode in place. Select Slew mode when you can modify configuration settings and click the Apply Changes button to execute the settings, as well as click the Sync Time Now button (when in Requested Mode) to adjust the time smoothly over time if there are time sensitive applications in this parameter. Select Step mode to configure the Network...
Manual
Page 25
Click Refresh to update current health status for Voltage, Power Supplies, Fans and Temperatures. 24 Define Auto Refresh Interval and Sensor Type form the drop-down list, and select Display Type. Server Information General Setting This page displays a real-time record of the system health related information such as Voltage, Power Supplies, Fans and Temperatures.
Click Refresh to update current health status for Voltage, Power Supplies, Fans and Temperatures. 24 Define Auto Refresh Interval and Sensor Type form the drop-down list, and select Display Type. Server Information General Setting This page displays a real-time record of the system health related information such as Voltage, Power Supplies, Fans and Temperatures.
Manual
Page 3
... 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IP Configuration...27 CPU Utilization...27...
... 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IP Configuration...27 CPU Utilization...27...
Manual
Page 5
... required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows 2008...
... required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows 2008...
Manual
Page 16
Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos.d/fedora.repo and /etc/yum.repos.d/fedora-updates.repo ([fedora] sections) Install PGDG RPM file: curl -O http://yum...
Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos.d/fedora.repo and /etc/yum.repos.d/fedora-updates.repo ([fedora] sections) Install PGDG RPM file: curl -O http://yum...
Manual
Page 31
... information. Chassis Power Control: Power control function to clear current group SEL. Gigabyte Server Management Console Click Clear to power on system. When you finish the configuration, click ON to power on /off/cycle and hard reset the remote host system. Displays the connected Node SEL information. Click Refresh to view the Node health information. Click on or power off system. - 31 - Click Refresh to power on...
... information. Chassis Power Control: Power control function to clear current group SEL. Gigabyte Server Management Console Click Clear to power on system. When you finish the configuration, click ON to power on /off/cycle and hard reset the remote host system. Displays the connected Node SEL information. Click Refresh to view the Node health information. Click on or power off system. - 31 - Click Refresh to power on...
Manual
Page 32
... Events screen, you can enable the generation of firmware. Select the file on your local system using Browse. BIOS can also choose to the new version of a specified device. BIOS Update Guide in Help page. To re-configure the power limit value, click Deactivate. Displays the Trap IP dstination list. To update the Trap IP Destination List, click Refresh. To configure Trap IPv4/IPv6 Denstination, check Enable box, enter IP...
... Events screen, you can enable the generation of firmware. Select the file on your local system using Browse. BIOS can also choose to the new version of a specified device. BIOS Update Guide in Help page. To re-configure the power limit value, click Deactivate. Displays the Trap IP dstination list. To update the Trap IP Destination List, click Refresh. To configure Trap IPv4/IPv6 Denstination, check Enable box, enter IP...
Manual
Page 38
... Copy catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Connection timeout between client and host system. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Power limit is...
... Copy catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Connection timeout between client and host system. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Power limit is...