Use and Care Manual
Page 1
....com (991.0365.017 rev 1) 49-80760 04-15 GE For a Spanish version of the hood. Wall Chimney Vent Hoods GEAppliances.com Safety Information 2, 3 Warranty 4 Assistance / Accessories 5 Using The Hood Controls 6 Filters 7, 8 Care and Cleaning Surfaces 9 Lights 9, 10 Troubleshooting Tips 12 Owner's Manual JVW5301 (30" Pyramid) JVW5361 (36" Pyramid) PVW7301 (30" Glass) PVW7361 (36" Glass) Write the model and serial numbers here: Model Serial You can find them on a label on the inside...
....com (991.0365.017 rev 1) 49-80760 04-15 GE For a Spanish version of the hood. Wall Chimney Vent Hoods GEAppliances.com Safety Information 2, 3 Warranty 4 Assistance / Accessories 5 Using The Hood Controls 6 Filters 7, 8 Care and Cleaning Surfaces 9 Lights 9, 10 Troubleshooting Tips 12 Owner's Manual JVW5301 (30" Pyramid) JVW5361 (36" Pyramid) PVW7301 (30" Glass) PVW7361 (36" Glass) Write the model and serial numbers here: Model Serial You can find them on a label on the inside...
Use and Care Manual
Page 2
..., ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. C. The fire is being switched on "Kitchen Fire Safety" published by the manufacturer. You can fight the fire with any solid-state speed control device. Before servicing or cleaning unit, switch power off the burner. CAUTION: TO REDUCE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE. C. READ AND SAVE THESE INSTRUCTIONS...
..., ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. C. The fire is being switched on "Kitchen Fire Safety" published by the manufacturer. You can fight the fire with any solid-state speed control device. Before servicing or cleaning unit, switch power off the burner. CAUTION: TO REDUCE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE. C. READ AND SAVE THESE INSTRUCTIONS...
Use and Care Manual
Page 3
... building code requirements. Clean ventilating fans frequently. D. Sufficient air is specifically recommended in accordance with all applicable codes and standards, including fire-rated construction. D. B. Grease should be vented to prevent back drafting. Use proper pan size. F. WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. Ŷ Do not attempt to adjacent rooms while working. Turn off breaker to repair or replace any makeup (replacement) air system in this manual. Never...
... building code requirements. Clean ventilating fans frequently. D. Sufficient air is specifically recommended in accordance with all applicable codes and standards, including fire-rated construction. D. B. Grease should be vented to prevent back drafting. Use proper pan size. F. WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. Ŷ Do not attempt to adjacent rooms while working. Turn off breaker to repair or replace any makeup (replacement) air system in this manual. Never...
Use and Care Manual
Page 4
... the USA. Warrantor: General Electric Company. Staple your home. Proof of the original purchase date is not available, you may be required to bring the product to repair or replace light bulbs, except for diagnostics. For the period of one -year warranty, GE will provide any part of the range which vary from the date of service. During this appliance. Ŷ...
... the USA. Warrantor: General Electric Company. Staple your home. Proof of the original purchase date is not available, you may be required to bring the product to repair or replace light bulbs, except for diagnostics. For the period of one -year warranty, GE will provide any part of the range which vary from the date of service. During this appliance. Ŷ...
Use and Care Manual
Page 5
... accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted).Order on-line today, 24 hours every day or by any user. Other servicing generally should be exercised, since improper servicing may cause unsafe operation. Caution must be used by people of all ages, sizes and capabilities. Contact Us: If you are available: Parts Charcoal Filter High Ceiling Duct Cover Kit Remote Control Replacement Lights Cleaning Supplies CitruShine Stainless Steel...
... accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted).Order on-line today, 24 hours every day or by any user. Other servicing generally should be exercised, since improper servicing may cause unsafe operation. Caution must be used by people of all ages, sizes and capabilities. Contact Us: If you are available: Parts Charcoal Filter High Ceiling Duct Cover Kit Remote Control Replacement Lights Cleaning Supplies CitruShine Stainless Steel...
Use and Care Manual
Page 7
... remove: 1. Repeat with the "locked" symbol on the blower. 4. Lift up the front side of the filter opening. The charcoal filter cannot be replaced. NOTE: The 30" models have 3 grease filters. Do not use . NOTE: DO NOT rinse, or put charcoal filter in the dishwasher. Place the side of the vent hood. For Recirculation Installation Only Charcoal Filter (Not Included) If the model is not vented to the outside, the air needs to...
... remove: 1. Repeat with the "locked" symbol on the blower. 4. Lift up the front side of the filter opening. The charcoal filter cannot be replaced. NOTE: The 30" models have 3 grease filters. Do not use . NOTE: DO NOT rinse, or put charcoal filter in the dishwasher. Place the side of the vent hood. For Recirculation Installation Only Charcoal Filter (Not Included) If the model is not vented to the outside, the air needs to...
Use and Care Manual
Page 8
... pivot to release the filter. Release the filter lock to be in place when the hood is not vented to the outside, the air needs to secure the filter in use abrasive cleansers. Filter Lock For Recirculation Installation Only Charcoal Filter (Not Included) If the model is in place. It must ALWAYS be recirculated through a disposable charcoal filter that the charcoal filter be replaced. Order Charcoal Filter JXCF71. Remove the metal filter-see Metal grease filter section.
... pivot to release the filter. Release the filter lock to be in place when the hood is not vented to the outside, the air needs to secure the filter in use abrasive cleansers. Filter Lock For Recirculation Installation Only Charcoal Filter (Not Included) If the model is in place. It must ALWAYS be recirculated through a disposable charcoal filter that the charcoal filter be replaced. Order Charcoal Filter JXCF71. Remove the metal filter-see Metal grease filter section.
Use and Care Manual
Page 9
... hands or cloth. Using a flathead screwdriver, unclip the wire lighting support and gently pull the support down from the hood. 3. Follow the cleaner instructions for painted surfaces. Replace it . NOTE: When cleaning, take care not to replace the lights, make sure that you , please call our toll-free number: National Parts Center 800.626.2002 GEApplianceParts.com Painted Surfaces (on some models) Do not use a steel wool pads or...
... hands or cloth. Using a flathead screwdriver, unclip the wire lighting support and gently pull the support down from the hood. 3. Follow the cleaner instructions for painted surfaces. Replace it . NOTE: When cleaning, take care not to replace the lights, make sure that you , please call our toll-free number: National Parts Center 800.626.2002 GEApplianceParts.com Painted Surfaces (on some models) Do not use a steel wool pads or...
Use and Care Manual
Page 10
... the metal trim ring from the lighting support. 4. Wear gloves. Do not touch the light with the two tabs on the lighting support with your bare fingers. CARE AND CLEANING: Lights Lights (Glass Models PVW7301, PVW7361) CAUTION: Allow lights to replace the lights, make sure that the light switch is turned off. 2. Wear clean gloves or use a paper towel to secure the light. 5. Remove the light by pulling towards the back of...
... the metal trim ring from the lighting support. 4. Wear gloves. Do not touch the light with the two tabs on the lighting support with your bare fingers. CARE AND CLEANING: Lights Lights (Glass Models PVW7301, PVW7361) CAUTION: Allow lights to replace the lights, make sure that the light switch is turned off. 2. Wear clean gloves or use a paper towel to secure the light. 5. Remove the light by pulling towards the back of...
Use and Care Manual
Page 24
.... Problem Fan/Light does not operate when either button is pressed Fan does not operate when fan Lo, Med, Hight buttons are not operating correctly Early light failure Possible Cause A house fuse may flip over and will cause reduced venting.Minimize the duct run length and number of the Vent Hood. Remove the filters and look up at the blower. Make sure your wall or roof cap has a blade or door. Clean the metal grease filter and replace charcoal filter (if...
.... Problem Fan/Light does not operate when either button is pressed Fan does not operate when fan Lo, Med, Hight buttons are not operating correctly Early light failure Possible Cause A house fuse may flip over and will cause reduced venting.Minimize the duct run length and number of the Vent Hood. Remove the filters and look up at the blower. Make sure your wall or roof cap has a blade or door. Clean the metal grease filter and replace charcoal filter (if...
Installation Instructions
Page 1
...'s use. • IMPORTANT ³ Observe all applicable codes and standards, including fire-rated construction. FOR YOUR SAFETY: WARNING: Before beginning the installation, switch power off breaker to Consumer - D. CAUTION: Due to the weight and size of these instructions for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Ducted fans must be vented to the outdoors. INSTALLATION INSTRUCTIONS Installation Pyramid Wall Instructions Chimney Vent Hoods...
...'s use. • IMPORTANT ³ Observe all applicable codes and standards, including fire-rated construction. FOR YOUR SAFETY: WARNING: Before beginning the installation, switch power off breaker to Consumer - D. CAUTION: Due to the weight and size of these instructions for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Ducted fans must be vented to the outdoors. INSTALLATION INSTRUCTIONS Installation Pyramid Wall Instructions Chimney Vent Hoods...
Installation Instructions
Page 2
... Installation Preparation PRODUCT DIMENSIONS 7-1/16" 8-1/4" 17-3/8" Min. 24-7/16" Max. 13" INSTALLATION CLEARANCES These vent hoods are designed to be installed onto a wall with no above cabinets. • Install these hoods between the required 24" minimum and recommended 36" maximum above the cooking surface. This hood must be installed between the required 24" minimum and 36" recommended maximum above the cooking surface. 30" to the ceiling. For supplied duct cover ceiling heights, see Recirculation Install...
... Installation Preparation PRODUCT DIMENSIONS 7-1/16" 8-1/4" 17-3/8" Min. 24-7/16" Max. 13" INSTALLATION CLEARANCES These vent hoods are designed to be installed onto a wall with no above cabinets. • Install these hoods between the required 24" minimum and recommended 36" maximum above the cooking surface. This hood must be installed between the required 24" minimum and 36" recommended maximum above the cooking surface. 30" to the ceiling. For supplied duct cover ceiling heights, see Recirculation Install...
Installation Instructions
Page 3
.... Recirculation Install Planning A recirculation duct (included) and two charcoal filters (not included) are in doubt whether the appliance is properly grounded. 31-10983 3 To maximize the ventilation performance of transitions and elbows. 2. Do not use an extension cord or adapter plug with local codes. Visit GEAppliances.com for venting exhaust to prevent any makeup (replacement) air system in accordance with damper at the exterior opening. Purchase the wall or roof cap and...
.... Recirculation Install Planning A recirculation duct (included) and two charcoal filters (not included) are in doubt whether the appliance is properly grounded. 31-10983 3 To maximize the ventilation performance of transitions and elbows. 2. Do not use an extension cord or adapter plug with local codes. Visit GEAppliances.com for venting exhaust to prevent any makeup (replacement) air system in accordance with damper at the exterior opening. Purchase the wall or roof cap and...
Installation Instructions
Page 4
...; 1 Literature Package PARTS NEEDED FOR INSTALLATION • 1 Strain Relief • Power Supply Cable • 1 Wall or Roof Cap (for external venting only) • All Metal Ductwork (for external venting only) • Recirculation Duct (for recirculation install only) WARNING: PERSONAL INJURY HAZARD Because of the weight and size of the duct cover. Failure to properly lift range hood could result in damage to protect against sharp edges. • Remove the duct covers. • Remove the hardware bag...
...; 1 Literature Package PARTS NEEDED FOR INSTALLATION • 1 Strain Relief • Power Supply Cable • 1 Wall or Roof Cap (for external venting only) • All Metal Ductwork (for external venting only) • Recirculation Duct (for recirculation install only) WARNING: PERSONAL INJURY HAZARD Because of the weight and size of the duct cover. Failure to properly lift range hood could result in damage to protect against sharp edges. • Remove the duct covers. • Remove the hardware bag...
Installation Instructions
Page 5
...16" Lower Duct Cover Max 8' 10-5/16" 9-7/8" Canopy 18-1/2" X = Distance From Hood To Cooktop (Varies depending on installation) X Required Min - 24", Recommended Max - 36" also consult cooktop manufacturer's recommendation For higher ceiling installations, the High Ceiling Duct Cover Kit (JXDC72) includes a new 20" lower duct cover which would replaces the 13" lower duct cover that came with the hood. 19-3/4" 36" RANGE HOOD RECIRCULATION COMPONENT Recirculation Duct HARDWARE COMPONENTS D F H I 31-10983 5 Duct Cover Screws B. Damper H. Mounting Screws Anchors E.
...16" Lower Duct Cover Max 8' 10-5/16" 9-7/8" Canopy 18-1/2" X = Distance From Hood To Cooktop (Varies depending on installation) X Required Min - 24", Recommended Max - 36" also consult cooktop manufacturer's recommendation For higher ceiling installations, the High Ceiling Duct Cover Kit (JXDC72) includes a new 20" lower duct cover which would replaces the 13" lower duct cover that came with the hood. 19-3/4" 36" RANGE HOOD RECIRCULATION COMPONENT Recirculation Duct HARDWARE COMPONENTS D F H I 31-10983 5 Duct Cover Screws B. Damper H. Mounting Screws Anchors E.
Installation Instructions
Page 6
... the wall (draw line up to be installed. Duct Covers 1. Remove the bracket to drill the 2 holes for the power supply cable to the ceiling) where the range hood will place the hood body onto these screw heads.) 4. Install the 2 mounting screws into the anchors. Mark 2 points on the wall so that its top edge is 1/16" from the ceiling and level. INSTALLATION PREPARATION Installation Preparation PREPARE THE WALL Hood Body and Power Supply...
... the wall (draw line up to be installed. Duct Covers 1. Remove the bracket to drill the 2 holes for the power supply cable to the ceiling) where the range hood will place the hood body onto these screw heads.) 4. Install the 2 mounting screws into the anchors. Mark 2 points on the wall so that its top edge is 1/16" from the ceiling and level. INSTALLATION PREPARATION Installation Preparation PREPARE THE WALL Hood Body and Power Supply...
Installation Instructions
Page 7
...: Recirculation duct (included) and charcoal filters JXCF72 (not included) are removed by placing the hood key holes over the vent exhaust outlet (B) and push down to Mount the Range Hood in the slots on the unit with the handles in front of the hood. Tighten the mounting screws. Insert 2 mounting screws into the 2 duct cover anchors (installed on the outlet. 3. A B Non-vented (recirculation) Installations (Continued) 2. Fit the recirculation duct over the mounting screws. MOUNT THE PYRAMID RANGE HOOD 1. A Mounting Screw Slots 2. Seal all connections...
...: Recirculation duct (included) and charcoal filters JXCF72 (not included) are removed by placing the hood key holes over the vent exhaust outlet (B) and push down to Mount the Range Hood in the slots on the unit with the handles in front of the hood. Tighten the mounting screws. Insert 2 mounting screws into the 2 duct cover anchors (installed on the outlet. 3. A B Non-vented (recirculation) Installations (Continued) 2. Fit the recirculation duct over the mounting screws. MOUNT THE PYRAMID RANGE HOOD 1. A Mounting Screw Slots 2. Seal all connections...
Installation Instructions
Page 8
... of the duct cover on blower and light. Attach the white lead of the power supply to slide the tabs under the green grounding screw. 2. Replace the junction box cover. Connect the green (D) ground wire under the ledge of the blower. FINISH THE INSTALLATION 1. For recirculation and ducted installation: 2. Turn the power supply on the blower. C B FINISH THE INSTALLATION (Continued) 3. Replace the grease filters. 8 5. If the range hood does not operate, check that the wiring connections have been...
... of the duct cover on blower and light. Attach the white lead of the power supply to slide the tabs under the green grounding screw. 2. Replace the junction box cover. Connect the green (D) ground wire under the ledge of the blower. FINISH THE INSTALLATION 1. For recirculation and ducted installation: 2. Turn the power supply on the blower. C B FINISH THE INSTALLATION (Continued) 3. Replace the grease filters. 8 5. If the range hood does not operate, check that the wiring connections have been...
Quick Specs
Page 1
..., when installed for vented to the low- hood installation height above the cooking surface depends upon ceiling height. Optional Accessories 9-3/4" JXDC72SS/ES-10(ft.) Ceiling Duct Cover Kit Max ceiling height installation with kit - 10'-0" JVW5301SJ_EJ 7" *Height to Ceiling 8-1/2" 30" Models Require a 30"-Wide Opening *The supplied duct cover fits 7'-4" to 8'-10" ceiling heights (10" with optional high ceiling kit JXDC72) JXRC70-Remote Control 18-1/2" 30" 9-3/4" JXCF72-Charcoal Filter 30" Models Require a 30"-Wide Opening (needed if used in inches) *Height Installation...
..., when installed for vented to the low- hood installation height above the cooking surface depends upon ceiling height. Optional Accessories 9-3/4" JXDC72SS/ES-10(ft.) Ceiling Duct Cover Kit Max ceiling height installation with kit - 10'-0" JVW5301SJ_EJ 7" *Height to Ceiling 8-1/2" 30" Models Require a 30"-Wide Opening *The supplied duct cover fits 7'-4" to 8'-10" ceiling heights (10" with optional high ceiling kit JXDC72) JXRC70-Remote Control 18-1/2" 30" 9-3/4" JXCF72-Charcoal Filter 30" Models Require a 30"-Wide Opening (needed if used in inches) *Height Installation...
Quick Specs
Page 2
Enjoy better visibility with boost - Select recirculating or external venting Remote control option - Stainless steel Model JVW5301EJES - Control your ventilation lighting and fan speed from anywhere in the kitchen Model JVW5301SJSS - Slate PVW7302SJSS Specification Revised 4/15 JVW5301SJ/EJ GE® 30" Wall-Mount Pyramid Chimney Hood Features and Benefits 350-CFM venting system with a brightly lit cooktop and surrounding surface Night light - Effectively remove smoke, grease, odor and moisture Electronic backlit controls - Keep a dim light on for visibility at all hours...
Enjoy better visibility with boost - Select recirculating or external venting Remote control option - Stainless steel Model JVW5301EJES - Control your ventilation lighting and fan speed from anywhere in the kitchen Model JVW5301SJSS - Slate PVW7302SJSS Specification Revised 4/15 JVW5301SJ/EJ GE® 30" Wall-Mount Pyramid Chimney Hood Features and Benefits 350-CFM venting system with a brightly lit cooktop and surrounding surface Night light - Effectively remove smoke, grease, odor and moisture Electronic backlit controls - Keep a dim light on for visibility at all hours...