Fluke 902 HVAC Clamp Meter Datasheet
Page 2
... Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006 Fluke Corporation. Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp...
... Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006 Fluke Corporation. Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp...
FE 902 Users Manual
Page 7
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
FE 902 Users Manual
Page 10
...avoid false readings that can be used to prevent shock and arc blast injury where hazardous live conductors are changed. • Do not hold the Meter anywhere beyond the tactile barrier, see Figure 1. • Adhere to electrical shock and injury, replace the batteries as soon as the low battery... indicator (B) appears. Such voltages pose a shock hazard. • Clean the case with voltages above 60 V dc or 30 V ac rms or 42 V ac peak. 902 Users Manual • Use caution when working with a damp cloth and mild detergent only. Individual protective equipment must...
...avoid false readings that can be used to prevent shock and arc blast injury where hazardous live conductors are changed. • Do not hold the Meter anywhere beyond the tactile barrier, see Figure 1. • Adhere to electrical shock and injury, replace the batteries as soon as the low battery... indicator (B) appears. Such voltages pose a shock hazard. • Clean the case with voltages above 60 V dc or 30 V ac rms or 42 V ac peak. 902 Users Manual • Use caution when working with a damp cloth and mild detergent only. Individual protective equipment must...
FE 902 Users Manual
Page 26
W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning. These solutions will react with a damp cloth and mild detergent. 20 Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. 902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning.
W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning. These solutions will react with a damp cloth and mild detergent. 20 Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. 902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning.
FE 902 Users Manual
Page 27
Turn the rotary switch to "OFF" and remove the test leads from the case bottom. 3. Use a Phillips screwdriver to possible electric shock or personal injury, replace the batteries as soon as the low battery indicator (B) appears. Disconnect the test...door to Figure 6): 1. Replace the batteries with two new AA batteries. 5. Remove the batteries. 4. To replace the batteries (refer to the case bottom and tighten the screw. 21 HVAC Clamp Meter Maintenance Battery Replacement XWWarning To avoid false readings that could lead to loosen the battery compartment door screw, and remove the...
Turn the rotary switch to "OFF" and remove the test leads from the case bottom. 3. Use a Phillips screwdriver to possible electric shock or personal injury, replace the batteries as soon as the low battery indicator (B) appears. Disconnect the test...door to Figure 6): 1. Replace the batteries with two new AA batteries. 5. Remove the batteries. 4. To replace the batteries (refer to the case bottom and tighten the screw. 21 HVAC Clamp Meter Maintenance Battery Replacement XWWarning To avoid false readings that could lead to loosen the battery compartment door screw, and remove the...