Fluke 787 and 789 Process Meter Datasheet
Page 1
... 1000 V safety-rated, true-rms multimeter In-field valve positioner checks Application Note (Literature code 2041342) Valve positioners open and close with mA source. Key Fluke 789 features: • 24 V loop power supply • HART mode setting with loop power (adds 250 ohm resistor) • Double-sized, dual display • 20 mA drive...
... 1000 V safety-rated, true-rms multimeter In-field valve positioner checks Application Note (Literature code 2041342) Valve positioners open and close with mA source. Key Fluke 789 features: • 24 V loop power supply • HART mode setting with loop power (adds 250 ohm resistor) • Double-sized, dual display • 20 mA drive...
FE 789 Users Manual
Page 9
... supply. It has all the features of this manual. To order replacement parts or spares, see Table 13 near the end of a digital multimeter, plus current output capability. ProcessMeter Introduction WWarning Read "Safety Information" before using the meter. The Fluke 789 ProcessMeter™ (referred to as... "the meter") is missing, contact the place of the nearest Fluke distributor or Service Center, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 ...
... supply. It has all the features of this manual. To order replacement parts or spares, see Table 13 near the end of a digital multimeter, plus current output capability. ProcessMeter Introduction WWarning Read "Safety Information" before using the meter. The Fluke 789 ProcessMeter™ (referred to as... "the meter") is missing, contact the place of the nearest Fluke distributor or Service Center, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 ...
FE 789 Users Manual
Page 13
... Series DMMs, or DMMs in general, read "Measuring Electrical Parameters" in addition to the sections referenced in "Getting Acquainted with the Fluke 80 Series DMM, read "Using the Current Output Functions," review the tables and figures in the previous paragraph. Later, use the ... COM V Pushbuttons Input/Output Jacks Figure 1. The sections following "Using the Current Output Functions" contain information about the various functions and features that can be used. Fluke 789 ProcessMeter anw014f.eps 5 How to Get Started If familiar with the Meter," and begin using the meter.
... Series DMMs, or DMMs in general, read "Measuring Electrical Parameters" in addition to the sections referenced in "Getting Acquainted with the Fluke 80 Series DMM, read "Using the Current Output Functions," review the tables and figures in the previous paragraph. Later, use the ... COM V Pushbuttons Input/Output Jacks Figure 1. The sections following "Using the Current Output Functions" contain information about the various functions and features that can be used. Fluke 789 ProcessMeter anw014f.eps 5 How to Get Started If familiar with the Meter," and begin using the meter.
FE 789 Users Manual
Page 14
789 Users Manual Getting Acquainted with the Meter To become familiar with the features and functions of the meter, study the following figures and tables. • Figure 2 and Table 2 describe the input/output jacks. • Figure 3 and Table 3 describe ...
789 Users Manual Getting Acquainted with the Meter To become familiar with the features and functions of the meter, study the following figures and tables. • Figure 2 and Table 2 describe the input/output jacks. • Figure 3 and Table 3 describe ...
FE 789 Users Manual
Page 27
... new stable reading. 19 Readings are still recorded, but the displayed average no longer changes. press H again to activate AutoHold. Press H to resume recording. This feature allows measurements to be off is disabled and auto ranging is recorded. The meter beeps and updates the display with each new stable reading (except...
... new stable reading. 19 Readings are still recorded, but the displayed average no longer changes. press H again to activate AutoHold. Press H to resume recording. This feature allows measurements to be off is disabled and auto ranging is recorded. The meter beeps and updates the display with each new stable reading (except...
FE 789 Users Manual
Page 28
789 Users Manual Compensating for Test Lead Resistance Use the relative reading feature (Q on the display will subtract the lead resistance. Use source mode whenever it is necessary to set the present measurement as a relative zero. The display looks the same in Figure 7. A common use for this feature is to see which pair of...
789 Users Manual Compensating for Test Lead Resistance Use the relative reading feature (Q on the display will subtract the lead resistance. Use source mode whenever it is necessary to set the present measurement as a relative zero. The display looks the same in Figure 7. A common use for this feature is to see which pair of...
FE 789 Users Manual
Page 36
789 Users Manual Option Change current span 0 % setting Disable beeper Disable auto power-off the meter power after 30 minutes of this option if MIN MAX recording is pushed), then shows firmware version. 28 Display HOLD (as long as button is on. Auto power off is disabled regardless of inactivity. Power-Up Options Pushbutton R G J (Blue) H Default Remembers last setting Enabled Enabled Disabled Action Taken Toggles between 0 - 20 mA and 4 - 20 mA range Disables beeper Disables the feature that turns off Display test/show firmware version Table 11.
789 Users Manual Option Change current span 0 % setting Disable beeper Disable auto power-off the meter power after 30 minutes of this option if MIN MAX recording is pushed), then shows firmware version. 28 Display HOLD (as long as button is on. Auto power off is disabled regardless of inactivity. Power-Up Options Pushbutton R G J (Blue) H Default Remembers last setting Enabled Enabled Disabled Action Taken Toggles between 0 - 20 mA and 4 - 20 mA range Disables beeper Disables the feature that turns off Display test/show firmware version Table 11.
FE 789 Users Manual
Page 39
... with a damp cloth and detergent; Contact a Fluke Service Center for instructions. 31 For maintenance procedures not described in this manual, contact a Fluke Service Center. Table 12 shows typical alkaline battery life.... Repair, calibration, and servicing not covered in this manual must be performed by qualified personnel. To preserve battery life: • Use current simulation instead of sourcing when possible. • Avoid using the backlight. • Do not disable the automatic power-off feature...
... with a damp cloth and detergent; Contact a Fluke Service Center for instructions. 31 For maintenance procedures not described in this manual, contact a Fluke Service Center. Table 12 shows typical alkaline battery life.... Repair, calibration, and servicing not covered in this manual must be performed by qualified personnel. To preserve battery life: • Use current simulation instead of sourcing when possible. • Avoid using the backlight. • Do not disable the automatic power-off feature...
Calibration Manual
Page 17
... preserve battery life: • Use current simulation instead of sourcing when possible. • Avoid using the backlight. • Do not disable the automatic power-off feature. • Turn the ProcessMeter off when not in use. Typical Alkaline Battery Life ProcessMeter Operation Measuring any parameter 140 Simulating Current 140 Sourcing 12 mA...
... preserve battery life: • Use current simulation instead of sourcing when possible. • Avoid using the backlight. • Do not disable the automatic power-off feature. • Turn the ProcessMeter off when not in use. Typical Alkaline Battery Life ProcessMeter Operation Measuring any parameter 140 Simulating Current 140 Sourcing 12 mA...