Fluke 787 and 789 Process Meter Datasheet
Page 1
...Lead Set plus alligator clips, 4 AA alkaline batteries (installed), product overview and users manual (CD-ROM) in 14 languages. Key Fluke 789 features: • 24 V loop power supply • HART mode setting with loop power (adds 250 ohm resistor) • ...III 1000 V safety-rated, true-rms multimeter In-field valve positioner checks Application Note (Literature code 2041342) Valve positioners open and close correctly. 31 Specifications - 787 and 789 ProcessMeter Measurement Function Best Accuracy Range and Resolution (% of reading + LSD) V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, ...
...Lead Set plus alligator clips, 4 AA alkaline batteries (installed), product overview and users manual (CD-ROM) in 14 languages. Key Fluke 789 features: • 24 V loop power supply • HART mode setting with loop power (adds 250 ohm resistor) • ...III 1000 V safety-rated, true-rms multimeter In-field valve positioner checks Application Note (Literature code 2041342) Valve positioners open and close correctly. 31 Specifications - 787 and 789 ProcessMeter Measurement Function Best Accuracy Range and Resolution (% of reading + LSD) V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, ...
FE 789 Users Manual
Page 4
789 Users Manual Auto Ramping the mA Output 26 Power-Up Options ...27 Loop Power Supply Mode 29 Battery Life ...31 Maintenance...31 General Maintenance ...31 Calibration ...31 Replacing a Fuse...34 If the Meter does not Work 34 Replacement Parts and Accessories 35 Specifications ...39 ii
789 Users Manual Auto Ramping the mA Output 26 Power-Up Options ...27 Loop Power Supply Mode 29 Battery Life ...31 Maintenance...31 General Maintenance ...31 Calibration ...31 Replacing a Fuse...34 If the Meter does not Work 34 Replacement Parts and Accessories 35 Specifications ...39 ii
FE 789 Users Manual
Page 26
... function switch to the cathode (side with band or bands). The meter should indicate the appropriate diode voltage drop. 5. See "Specifications" for taking measurements follows: 1. Testing Diodes To test a single diode: 1. Reverse the probes. Plug the test leads into the COM jack.... 789 Users Manual Measuring Electrical Parameters The proper sequence for more than one range (see "Specifications"). Set the rotary function switch to the lowest range. At the highest range, it is changed to ...
... function switch to the cathode (side with band or bands). The meter should indicate the appropriate diode voltage drop. 5. See "Specifications" for taking measurements follows: 1. Testing Diodes To test a single diode: 1. Reverse the probes. Plug the test leads into the COM jack.... 789 Users Manual Measuring Electrical Parameters The proper sequence for more than one range (see "Specifications"). Set the rotary function switch to the lowest range. At the highest range, it is changed to ...
FE 789 Users Manual
Page 39
... provides some basic maintenance procedures. Table 12 shows typical alkaline battery life. Repair, calibration, and servicing not covered in this manual, contact a Fluke Service Center. Calibration Calibrate the meter once a year to ensure that it performs according to possible electric shock or personal injury, replace the battery...Maintenance Periodically wipe the case with a damp cloth and detergent; Battery Life WWarning To avoid false readings, which could lead to its specifications. For maintenance procedures not described in use abrasives or solvents. do not use .
... provides some basic maintenance procedures. Table 12 shows typical alkaline battery life. Repair, calibration, and servicing not covered in this manual, contact a Fluke Service Center. Calibration Calibrate the meter once a year to ensure that it performs according to possible electric shock or personal injury, replace the battery...Maintenance Periodically wipe the case with a damp cloth and detergent; Battery Life WWarning To avoid false readings, which could lead to its specifications. For maintenance procedures not described in use abrasives or solvents. do not use .
FE 789 Users Manual
Page 47
... is 1 year. DC Volts Measurement Range (V dc) Resolution Accuracy, ±(% of the least significant digit. All specifications assume a 5-minute warm-up period. ProcessMeter Specifications Specifications All specifications apply from +18 °C to the number of increments or decrements of Reading + Counts) 4.000 0.001 V 0.1 % + 1 40.00 0.01 V 0.1 % + 1 400.0 0.1 V 0.1 % + 1 1000 1 V 0.1 % + 1 Input impedance: 10 MΩ (...
... is 1 year. DC Volts Measurement Range (V dc) Resolution Accuracy, ±(% of the least significant digit. All specifications assume a 5-minute warm-up period. ProcessMeter Specifications Specifications All specifications apply from +18 °C to the number of increments or decrements of Reading + Counts) 4.000 0.001 V 0.1 % + 1 40.00 0.01 V 0.1 % + 1 400.0 0.1 V 0.1 % + 1 1000 1 V 0.1 % + 1 Input impedance: 10 MΩ (...
FE 789 Users Manual
Page 48
789 Users Manual DC Millivolts Measurement Range (mV dc) Resolution Accuracy, ±(% of Reading + Counts) 400.0 0. 1 mV 0.1 % + 2 AC Volts Measurement Accuracy, ±(%... Hz to 200 Hz 200 Hz to 500 Hz 400.0 mV 0.1 mV 0.7 % + 4 1.2 % + 4 7.0 % + 4 4.000 V 0.001 V 0.7 % + 2 1.2 % + 4 7.0 % + 4 40.00 V 400.0 V 0.01 V 0.1 V 0.7 % + 2 0.7 % + 2 1.2 % + 4 1.2 % + 4 7.0 % + 4 7.0 % + 4 1000 V 1 V 0.7 % + 2 Specifications are valid from 5 % to 100 % of amplitude range. AC conversion: true rms Maximum crest factor: 3 (between 50 and 60 Hz) For non-sinusoidal waveforms, add...
789 Users Manual DC Millivolts Measurement Range (mV dc) Resolution Accuracy, ±(% of Reading + Counts) 400.0 0. 1 mV 0.1 % + 2 AC Volts Measurement Accuracy, ±(%... Hz to 200 Hz 200 Hz to 500 Hz 400.0 mV 0.1 mV 0.7 % + 4 1.2 % + 4 7.0 % + 4 4.000 V 0.001 V 0.7 % + 2 1.2 % + 4 7.0 % + 4 40.00 V 400.0 V 0.01 V 0.1 V 0.7 % + 2 0.7 % + 2 1.2 % + 4 1.2 % + 4 7.0 % + 4 7.0 % + 4 1000 V 1 V 0.7 % + 2 Specifications are valid from 5 % to 100 % of amplitude range. AC conversion: true rms Maximum crest factor: 3 (between 50 and 60 Hz) For non-sinusoidal waveforms, add...
FE 789 Users Manual
Page 49
...45 Hz to 2 kHz Resolution Accuracy, ±(% of Reading + Counts) 1.000 A (Note) 0.001 A 1 % + 2 Note: 440 mA continuous, 1 A 30 seconds maximum Specifications are valid from 5 % to 100 % of Reading + Counts) 30.000 mA 0.001 mA 0.05 % + 2 1.000 A (Note) 0.001 A 0.2 % + 2 Note...: 440 mA continuous, 1 A 30 seconds maximum Overload protection: 440 mA, 1000 V fast-blow fuse ProcessMeter Specifications Typical Burden Voltage 1.5 V/A Typical Burden Voltage 14 mV/mA 1.5 V/A 41 AC conversion: true rms Maximum crest factor: 3 (between 50 and 60 Hz) For ...
...45 Hz to 2 kHz Resolution Accuracy, ±(% of Reading + Counts) 1.000 A (Note) 0.001 A 1 % + 2 Note: 440 mA continuous, 1 A 30 seconds maximum Specifications are valid from 5 % to 100 % of Reading + Counts) 30.000 mA 0.001 mA 0.05 % + 2 1.000 A (Note) 0.001 A 0.2 % + 2 Note...: 440 mA continuous, 1 A 30 seconds maximum Overload protection: 440 mA, 1000 V fast-blow fuse ProcessMeter Specifications Typical Burden Voltage 1.5 V/A Typical Burden Voltage 14 mV/mA 1.5 V/A 41 AC conversion: true rms Maximum crest factor: 3 (between 50 and 60 Hz) For ...
FE 789 Users Manual
Page 51
ProcessMeter Specifications Frequency Counter Accuracy Range Resolution 199.99 Hz 0.01 Hz 1999.9 Hz 0.1 Hz 19.999 kHz 0.001 kHz Display updates 3 times/second at > 10 Hz Accuracy, ±(% of Reading + Counts) 0.005 % + 1 0.005 % + 1 0.005 % + 1 Frequency Counter Sensitivity Input Range 400 mV Minimum Sensitivity (rms Sinewave) 5 Hz to 5 kHz* AC DC (approximate trigger level 5 % of full scale) 150 mV (50 Hz to 5 kHz) 150 mV 4 V 1 V 1 V 40 V 4 V 4 V 400 V 40 V 40 V 1000 V 400 V 400 V *Usable 0.5 Hz to 20 kHz with reduced sensitivity. 106 VHz max 43
ProcessMeter Specifications Frequency Counter Accuracy Range Resolution 199.99 Hz 0.01 Hz 1999.9 Hz 0.1 Hz 19.999 kHz 0.001 kHz Display updates 3 times/second at > 10 Hz Accuracy, ±(% of Reading + Counts) 0.005 % + 1 0.005 % + 1 0.005 % + 1 Frequency Counter Sensitivity Input Range 400 mV Minimum Sensitivity (rms Sinewave) 5 Hz to 5 kHz* AC DC (approximate trigger level 5 % of full scale) 150 mV (50 Hz to 5 kHz) 150 mV 4 V 1 V 1 V 40 V 4 V 4 V 400 V 40 V 40 V 1000 V 400 V 400 V *Usable 0.5 Hz to 20 kHz with reduced sensitivity. 106 VHz max 43
FE 789 Users Manual
Page 52
789 Users Manual Diode Test and Continuity Test Diode test indication: Displays voltage drop across device, 2.0 V full scale. Continuity test indication: Continuous audible tone for test ... overrange to 24 mA Accuracy: 0.05 % of span1 Loop voltage: 24 V nominal, 48 V maximum, 15 V minimum Compliance voltage: 21 V for 24 V supply Burden voltage: < 3 V General Specifications Maximum voltage applied between any jack and earth ground: 1000 V Storage temperature: -40 °C to 60 °C Operating temperature: -20 °C to 55 °C Operating...
789 Users Manual Diode Test and Continuity Test Diode test indication: Displays voltage drop across device, 2.0 V full scale. Continuity test indication: Continuous audible tone for test ... overrange to 24 mA Accuracy: 0.05 % of span1 Loop voltage: 24 V nominal, 48 V maximum, 15 V minimum Compliance voltage: 21 V for 24 V supply Burden voltage: < 3 V General Specifications Maximum voltage applied between any jack and earth ground: 1000 V Storage temperature: -40 °C to 60 °C Operating temperature: -20 °C to 55 °C Operating...
FE 789 Users Manual
Page 53
Accuracy adders for use in RF Fields: In an RF field of 3 V/m, change the accuracy specifications as follows: For AC Volts Measurement, add 0.25 % of range For DC Current Measurement, 30.000 mA range, add 0.14 % or range For DC Current ... Hz Shock: 1 meter drop test Safety: Complies with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III. ProcessMeter Specifications Certifications: , , , Power requirements: Four AA batteries (alkaline recommended) Size: 10.0 cm X 20.3 cm X 5.0 cm (3.94 in X 8.00 in X 1.97 in RF fields...
Accuracy adders for use in RF Fields: In an RF field of 3 V/m, change the accuracy specifications as follows: For AC Volts Measurement, add 0.25 % of range For DC Current Measurement, 30.000 mA range, add 0.14 % or range For DC Current ... Hz Shock: 1 meter drop test Safety: Complies with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III. ProcessMeter Specifications Certifications: , , , Power requirements: Four AA batteries (alkaline recommended) Size: 10.0 cm X 20.3 cm X 5.0 cm (3.94 in X 8.00 in X 1.97 in RF fields...
Calibration Manual
Page 1
All rights reserved. 789 ProcessMeter™ Calibration Manual September 2002, Rev.1, 3/13 © 2002-2013 Fluke Corporation. Specifications are trademarks of their respective companies. All product names are subject to change without notice.
All rights reserved. 789 ProcessMeter™ Calibration Manual September 2002, Rev.1, 3/13 © 2002-2013 Fluke Corporation. Specifications are trademarks of their respective companies. All product names are subject to change without notice.
Calibration Manual
Page 2
... reseller, and does not apply to fuses, disposable batteries, or to Buyer, transportation prepaid (FOB Destination). Fluke assumes no authority to that service center, with its functional specifications for importation costs of repair/replacement parts when product purchased in material and workmanship under normal use outside the product's specified rating, or normal...
... reseller, and does not apply to fuses, disposable batteries, or to Buyer, transportation prepaid (FOB Destination). Fluke assumes no authority to that service center, with its functional specifications for importation costs of repair/replacement parts when product purchased in material and workmanship under normal use outside the product's specified rating, or normal...
Calibration Manual
Page 3
Table of Contents Title Page Introduction...1 How to Contact Fluke 1 Safety Information 2 Symbols ...3 Specifications...4 Required Equipment 7 Basic Maintenance 8 Cleaning the ProcessMeter 8 Replacing the Batteries 8 Battery Life...9 Checking and Replacing the Fuses 10 Calibration Verification 10 Preparing to Perform Calibration ...
Table of Contents Title Page Introduction...1 How to Contact Fluke 1 Safety Information 2 Symbols ...3 Specifications...4 Required Equipment 7 Basic Maintenance 8 Cleaning the ProcessMeter 8 Replacing the Batteries 8 Battery Life...9 Checking and Replacing the Fuses 10 Calibration Verification 10 Preparing to Perform Calibration ...
Calibration Manual
Page 9
...the 789 ProcessMeter (hereafter, also referred to as "the ProcessMeter" or "the UUT") provides the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE ...do so, follow the standard practices for the use of the following information: • Precautions and Safety information • Specifications • Basic maintenance (cleaning, replacing the batteries and fuses) • Calibration verification test procedures • Calibration adjustment procedures...
...the 789 ProcessMeter (hereafter, also referred to as "the ProcessMeter" or "the UUT") provides the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE ...do so, follow the standard practices for the use of the following information: • Precautions and Safety information • Specifications • Basic maintenance (cleaning, replacing the batteries and fuses) • Calibration verification test procedures • Calibration adjustment procedures...
Calibration Manual
Page 12
Note "Counts" refers to the number of increments or decrements of amplitude range. The standard specification interval is 1 year. DC Volts Measurement Range (V dc) 4.000 40.00 400.0 1000 ...V 0.01 V 0.1 V 1 V 0.7 % + 2 0.7 % + 2 0.7 % + 2 0.7 % + 2 1.2 % + 4 1.2 % + 4 1.2 % + 4 1.2 % + 4 7.0 % + 4 7.0 % + 4 7.0 % + 4 7.0 % + 4 Specifications are valid from +18 °C to +28 °C unless stated otherwise. All specifications assume a 5-minute warm-up period. 789 Calibration Manual Specifications All specifications apply from 5 % to 100 % of the least significant digit.
Note "Counts" refers to the number of increments or decrements of amplitude range. The standard specification interval is 1 year. DC Volts Measurement Range (V dc) 4.000 40.00 400.0 1000 ...V 0.01 V 0.1 V 1 V 0.7 % + 2 0.7 % + 2 0.7 % + 2 0.7 % + 2 1.2 % + 4 1.2 % + 4 1.2 % + 4 1.2 % + 4 7.0 % + 4 7.0 % + 4 7.0 % + 4 7.0 % + 4 Specifications are valid from +18 °C to +28 °C unless stated otherwise. All specifications assume a 5-minute warm-up period. 789 Calibration Manual Specifications All specifications apply from 5 % to 100 % of the least significant digit.
Calibration Manual
Page 13
... Current Measurement Range 45 Hz to 2 kHz Resolution Accuracy, ±(% of Reading + Counts) 1.000 A (Note) 0.001 A 1 % + 2 Note: 440 mA continuous, 1 A 30 seconds maximum Specifications are valid from 5 % to 100 % of Reading + Counts) 0.005 % + 1 0.005 % + 1 0.005 % + 1 5 AC conversion: true rms Maximum crest factor: 3 (between 50 and 60 Hz) For non-...
... Current Measurement Range 45 Hz to 2 kHz Resolution Accuracy, ±(% of Reading + Counts) 1.000 A (Note) 0.001 A 1 % + 2 Note: 440 mA continuous, 1 A 30 seconds maximum Specifications are valid from 5 % to 100 % of Reading + Counts) 0.005 % + 1 0.005 % + 1 0.005 % + 1 5 AC conversion: true rms Maximum crest factor: 3 (between 50 and 60 Hz) For non-...
Calibration Manual
Page 15
... model is intended for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it meets the specifications indicated. Warning To avoid safety hazards and equipment damage during the calibration procedure, use in some cases other equipment... Equipment (Industrial Broadcasting & Communication Equipment[1] [1] .. This equipment is not available, in business environments and not to use a Fluke 5500A calibrator or Agilent 3458A. This product meets requirements for use the specified calibration equipment listed in Table 2.
... model is intended for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it meets the specifications indicated. Warning To avoid safety hazards and equipment damage during the calibration procedure, use in some cases other equipment... Equipment (Industrial Broadcasting & Communication Equipment[1] [1] .. This equipment is not available, in business environments and not to use a Fluke 5500A calibrator or Agilent 3458A. This product meets requirements for use the specified calibration equipment listed in Table 2.
Calibration Manual
Page 16
... that the slot is preferable Fluke Model 5500A Fluke 787 ProcessMeter 741,743, or 744 Process Calibrator Agilent 3458A Fluke 5440A-7002 Low Thermal Test Leads --- Remove the ProcessMeter's batteries. 5. Required Equipment and Software Minimum Specifications Recommended Model No Substitute No... With a standard blade hand screwdriver, turn the ProcessMeter OFF. 2. Replace with the screw picture molded into the case. 3. 789 Calibration Manual Equipment Calibration Source Digital Process Meter or Digital Process Calibrator Digital Multimeter Test Leads, low leakage, RG-58/U type...
... that the slot is preferable Fluke Model 5500A Fluke 787 ProcessMeter 741,743, or 744 Process Calibrator Agilent 3458A Fluke 5440A-7002 Low Thermal Test Leads --- Remove the ProcessMeter's batteries. 5. Required Equipment and Software Minimum Specifications Recommended Model No Substitute No... With a standard blade hand screwdriver, turn the ProcessMeter OFF. 2. Replace with the screw picture molded into the case. 3. 789 Calibration Manual Equipment Calibration Source Digital Process Meter or Digital Process Calibrator Digital Multimeter Test Leads, low leakage, RG-58/U type...
Calibration Manual
Page 18
... Move red test lead to . 2. Refer to the ProcessMeter, use only the specified replacement fuse, 440 mA 1000 V fast-blow, Fluke PN 943121. The specifications assume the ProcessMeter has been warmed up for one end loose, then sliding the fuse out of +18 °C to +28 °... turn the ProcessMeter OFF. 2. The ProcessMeter's performance and accuracy are specified for 5 minutes before handling the test connections or test cables. 789 Calibration Manual Checking and Replacing the Fuses Warning To avoid personal injury or damage to Figure 1 as follows. To determine ...
... Move red test lead to . 2. Refer to the ProcessMeter, use only the specified replacement fuse, 440 mA 1000 V fast-blow, Fluke PN 943121. The specifications assume the ProcessMeter has been warmed up for one end loose, then sliding the fuse out of +18 °C to +28 °... turn the ProcessMeter OFF. 2. The ProcessMeter's performance and accuracy are specified for 5 minutes before handling the test connections or test cables. 789 Calibration Manual Checking and Replacing the Fuses Warning To avoid personal injury or damage to Figure 1 as follows. To determine ...
Calibration Manual
Page 19
...176;C (64.4 °F and 82.4 °F) and that the person performing the tests has read the 789 Users Manual, knows how to select functions and ranges on the ProcessMeter or the multimeter falls within the acceptable...a different calibrator or DMM make the connections appropriate for the calibration verification tests in Table 2. If using Fluke's MET/CAL Calibration Software). ProcessMeter™ Calibration Verification values, and determine if the reading on ...calibrator and multimeter as required by their specifications. 5. Make sure that the UUT is available (see Table 2). 2.
...176;C (64.4 °F and 82.4 °F) and that the person performing the tests has read the 789 Users Manual, knows how to select functions and ranges on the ProcessMeter or the multimeter falls within the acceptable...a different calibrator or DMM make the connections appropriate for the calibration verification tests in Table 2. If using Fluke's MET/CAL Calibration Software). ProcessMeter™ Calibration Verification values, and determine if the reading on ...calibrator and multimeter as required by their specifications. 5. Make sure that the UUT is available (see Table 2). 2.