Fluke 741B, 743B, and 744 Process Calibrator Datasheet
Page 1
...Offer one and two-year calibration cycles and a three-year warranty (one -year. When you to monitor, control, and calibrate HART instrumentation. Ordering information Fluke-741B Documenting Process Calibrator Fluke-743B Documenting Process Calibrator Fluke-744 Documenting Process Calibrator For more information, go ... sets), TP220 Test Probes, BP7217 Battery Pack, BC7217 Battery Charger, instruction manual, NIST Traceable calibration certificate and data, three year warranty, serial port cable (743B and 744 only), DPC/TRACK Sample Version with software - Battery life: Typically over eight...
...Offer one and two-year calibration cycles and a three-year warranty (one -year. When you to monitor, control, and calibrate HART instrumentation. Ordering information Fluke-741B Documenting Process Calibrator Fluke-743B Documenting Process Calibrator Fluke-744 Documenting Process Calibrator For more information, go ... sets), TP220 Test Probes, BP7217 Battery Pack, BC7217 Battery Charger, instruction manual, NIST Traceable calibration certificate and data, three year warranty, serial port cable (743B and 744 only), DPC/TRACK Sample Version with software - Battery life: Typically over eight...
Fluke 744 Users Manual
Page 1
Users Manual All rights reserved. All product names are trademarks of their respective companies. Printed in U.S.A. ® 744 Documenting Process Calibrator PN 691287 September 1998 Rev.1, 2/99 © 1998,1999 Fluke Corporation.
Users Manual All rights reserved. All product names are trademarks of their respective companies. Printed in U.S.A. ® 744 Documenting Process Calibrator PN 691287 September 1998 Rev.1, 2/99 © 1998,1999 Fluke Corporation.
Fluke 744 Users Manual
Page 4
744 Users Manual Displaying the Date and Time 24 Using the Backlight 26 Personalizing the Calibrator 26 Using Measure Mode...28 Measurement Ranges 28 Measuring Electrical Parameters 28 Testing Continuity ...30 Measuring Pressure 30 Measuring Temperature 34 Using Thermocouples 34 Using ...
744 Users Manual Displaying the Date and Time 24 Using the Backlight 26 Personalizing the Calibrator 26 Using Measure Mode...28 Measurement Ranges 28 Measuring Electrical Parameters 28 Testing Continuity ...30 Measuring Pressure 30 Measuring Temperature 34 Using Thermocouples 34 Using ...
Fluke 744 Users Manual
Page 5
Contents (continued) Using Manual Step 60 Using Auto Step 61 Ramping the Output 62 Simultaneous Measure/Source 65 Calibrating a Process Instrument 68 Generating "As Found" Test Data 68 Adjusting the Transmitter 73 "As Left" Test Run ...74 Test Comments ...75 Calibrating a Delta-Pressure Flow Instrument 75 Calibrating a Limit Switch 76 Transmitter Mode ...79 Memory Operations... Value 88 Quick Guide to Applications 88 Communicating with a PC 98 Maintenance...98 Replacing the Battery Pack 98 Internal Lithium Backup Battery 99 Cleaning the Calibrator 99 iii
Contents (continued) Using Manual Step 60 Using Auto Step 61 Ramping the Output 62 Simultaneous Measure/Source 65 Calibrating a Process Instrument 68 Generating "As Found" Test Data 68 Adjusting the Transmitter 73 "As Left" Test Run ...74 Test Comments ...75 Calibrating a Delta-Pressure Flow Instrument 75 Calibrating a Limit Switch 76 Transmitter Mode ...79 Memory Operations... Value 88 Quick Guide to Applications 88 Communicating with a PC 98 Maintenance...98 Replacing the Battery Pack 98 Internal Lithium Backup Battery 99 Cleaning the Calibrator 99 iii
Fluke 744 Users Manual
Page 6
744 Users Manual Calibration Data ...99 In Case of Difficulty 99 Service Center Calibration or Repair 100 Replacement Parts ...101 Accessories...102 Specifications...104 DC Voltage Measurement 105 AC Voltage Measurement 106 DC Current Measurement 107 Resistance Measurement 107 ...
744 Users Manual Calibration Data ...99 In Case of Difficulty 99 Service Center Calibration or Repair 100 Replacement Parts ...101 Accessories...102 Specifications...104 DC Voltage Measurement 105 AC Voltage Measurement 106 DC Current Measurement 107 Resistance Measurement 107 ...
Fluke 744 Users Manual
Page 10
.... Checking a Switch ...94 33. Limit Switch Terminology...76 25. Calibrating a Current-to -Current (P/I /P) Transmitter 91 29. Calibrating a Pressure-to -Pressure (I ) Transmitter 95 35. Checking a Relay Output Trip Alarm 64 23. Calibrating a Chart Recorder 89 26. Monitoring AC Line Voltage and Frequency 90 28. 744 Users Manual 18. Measuring Voltage Drop ...89 27. Measuring a Precision Resistor...
.... Checking a Switch ...94 33. Limit Switch Terminology...76 25. Calibrating a Current-to -Current (P/I /P) Transmitter 91 29. Calibrating a Pressure-to -Pressure (I ) Transmitter 95 35. Checking a Relay Output Trip Alarm 64 23. Calibrating a Chart Recorder 89 26. Monitoring AC Line Voltage and Frequency 90 28. 744 Users Manual 18. Measuring Voltage Drop ...89 27. Measuring a Precision Resistor...
Fluke 744 Users Manual
Page 11
... an external temperature reference. The ability to store results for instructions on process instruments. Documenting Process Calibrator Introduction The Fluke 744 Documenting Process Calibrator (hereafter referred to as the calibrator) is unstable. A summary of the manual. Or, you set the display to use the HART communication feature. A setup option that measures and sources electrical and physical...
... an external temperature reference. The ability to store results for instructions on process instruments. Documenting Process Calibrator Introduction The Fluke 744 Documenting Process Calibrator (hereafter referred to as the calibrator) is unstable. A summary of the manual. Or, you set the display to use the HART communication feature. A setup option that measures and sources electrical and physical...
Fluke 744 Users Manual
Page 12
744 Users Manual The ability to automatically log up to the next. Built-in which the calibrator can be configured to engineering units, percent of scale, square-law outputs, or custom units. Trip detect is either a 1 V change or a continuity status change (Open ...or Short) from one ramp increment to 8,000 data points. To contact Fluke...
744 Users Manual The ability to automatically log up to the next. Built-in which the calibrator can be configured to engineering units, percent of scale, square-law outputs, or custom units. Trip detect is either a 1 V change or a continuity status change (Open ...or Short) from one ramp increment to 8,000 data points. To contact Fluke...
Fluke 744 Users Manual
Page 13
... 946769) • Jumper for three-wire RTD measurement connections (two included, PN 944632) Documenting Process Calibrator Standard Equipment • 744 Users Manual English (PN 691287) French (PN 691300) German (PN 691311) Italian (PN 691318) Spanish (PN 691303) • 744 HART® Mode Users Guide English (PN 691292) French (PN 691326) German (PN 691334) Italian...
... 946769) • Jumper for three-wire RTD measurement connections (two included, PN 944632) Documenting Process Calibrator Standard Equipment • 744 Users Manual English (PN 691287) French (PN 691300) German (PN 691311) Italian (PN 691318) Spanish (PN 691303) • 744 HART® Mode Users Guide English (PN 691292) French (PN 691326) German (PN 691334) Italian...
Fluke 744 Users Manual
Page 17
...European Union directives. Definition of Impluse Withstand Voltage protection provided. Use the calibrator only as specified in manual Common (LO) Input equipotentiality Equipment protected throughout by the calibrator may be impaired. AC-Alternating Current DC-Direct Current Fuse Pressure ON/... relevent Canadian Standards Association directives. Mains Wall outlets, local appliances and PORTABLE EQUIPMENT. Symbols used on the calibrator and in this manual, otherwise the protection provided by DOUBLE INSULATION or REINFORCED INSULATION Conforms to the level of Symbols gj56f.eps 7...
...European Union directives. Definition of Impluse Withstand Voltage protection provided. Use the calibrator only as specified in manual Common (LO) Input equipotentiality Equipment protected throughout by the calibrator may be impaired. AC-Alternating Current DC-Direct Current Fuse Pressure ON/... relevent Canadian Standards Association directives. Mains Wall outlets, local appliances and PORTABLE EQUIPMENT. Symbols used on the calibrator and in this manual, otherwise the protection provided by DOUBLE INSULATION or REINFORCED INSULATION Conforms to the level of Symbols gj56f.eps 7...
Fluke 744 Users Manual
Page 18
...that pose hazards to the insulation surrounding the connectors. • Disconnect the power and discharge all highvoltage capacitors in doubt, have the calibrator serviced. • Select the proper function and range for your fingers away from the probe contacts. Check test lead continuity. Such voltages...Do not use the calibrator if it is a low battery indication on the probes. • Connect the common test lead before using the probes, keep your measurement. • Use caution when working above 30 V ac rms, 42 V ac pk, or 60 V dc. 744 Users Manual Safety Information (cont...
...that pose hazards to the insulation surrounding the connectors. • Disconnect the power and discharge all highvoltage capacitors in doubt, have the calibrator serviced. • Select the proper function and range for your fingers away from the probe contacts. Check test lead continuity. Such voltages...Do not use the calibrator if it is a low battery indication on the probes. • Connect the common test lead before using the probes, keep your measurement. • Use caution when working above 30 V ac rms, 42 V ac pk, or 60 V dc. 744 Users Manual Safety Information (cont...
Fluke 744 Users Manual
Page 20
..., and you will make it easier to understand the instructions in the calibrator. 3. The calibrator is simultaneously sourcing dc volts and measuring dc volts. When you first unpack the calibrator, you can see the active measurements at the top of the manual. 1. 744 Users Manual Getting Started Exercise The following is a brief getting started exercise that...
..., and you will make it easier to understand the instructions in the calibrator. 3. The calibrator is simultaneously sourcing dc volts and measuring dc volts. When you first unpack the calibrator, you can see the active measurements at the top of the manual. 1. 744 Users Manual Getting Started Exercise The following is a brief getting started exercise that...
Fluke 744 Users Manual
Page 22
...Battery Eliminator. Pressure module connector TC input/output wMEAS V jacks wSOURCE mA, MEAS mA Ω RTD jacks wSOURCE V Ω RTD jacks Connects the calibrator to center. This jack accepts a miniature polarized thermocouple plug with flat, in-line blades spaced 7.9 mm (0.312 in) center to a pressure module...., and for measuring voltage, frequency, or three- Input jacks for simulating RTDs. 12 Table 2. or four-wire RTDs (Resistance Temperature Detectors). 744 Users Manual Operating Features Input and Output Jacks Figure 5 shows the calibrator input and output jacks.
...Battery Eliminator. Pressure module connector TC input/output wMEAS V jacks wSOURCE mA, MEAS mA Ω RTD jacks wSOURCE V Ω RTD jacks Connects the calibrator to center. This jack accepts a miniature polarized thermocouple plug with flat, in-line blades spaced 7.9 mm (0.312 in) center to a pressure module...., and for measuring voltage, frequency, or three- Input jacks for simulating RTDs. 12 Table 2. or four-wire RTDs (Resistance Temperature Detectors). 744 Users Manual Operating Features Input and Output Jacks Figure 5 shows the calibrator input and output jacks.
Fluke 744 Users Manual
Page 24
... SOURCE 30V MEAS 30V 300V TC MAX MAX 12 Figure 6. Keys 4 5 6 7 8 9 10 11 ot06f.eps The softkeys are shown in this manual in bold type, for example, Choices. 14 744 DOCUMENTING PROCESS CALIBRATOR 16 15 14 13 123 MEAS SOURCE mA SETUP V V Hz TC RTD 7 8 9 CLEAR ( ZERO) 4 5 6 1 2 3 0 . Softkey functions are defined by the...
... SOURCE 30V MEAS 30V 300V TC MAX MAX 12 Figure 6. Keys 4 5 6 7 8 9 10 11 ot06f.eps The softkeys are shown in this manual in bold type, for example, Choices. 14 744 DOCUMENTING PROCESS CALIBRATOR 16 15 14 13 123 MEAS SOURCE mA SETUP V V Hz TC RTD 7 8 9 CLEAR ( ZERO) 4 5 6 1 2 3 0 . Softkey functions are defined by the...
Fluke 744 Users Manual
Page 30
...Note When you remove a charged battery from the charger, wait for the blinking indicator to go off before you use the calibrator for the battery charger to line power. Switching between charging modes is maintained after that time in fast-charge mode (steady ...indicator light on the charger). 744 Users Manual Charging the Battery wBefore you insert a discharged battery. The charger automatically senses line voltage and adjusts itself accordingly. It takes about...
...Note When you remove a charged battery from the charger, wait for the blinking indicator to go off before you use the calibrator for the battery charger to line power. Switching between charging modes is maintained after that time in fast-charge mode (steady ...indicator light on the charger). 744 Users Manual Charging the Battery wBefore you insert a discharged battery. The charger automatically senses line voltage and adjusts itself accordingly. It takes about...
Fluke 744 Users Manual
Page 32
... battery life and best performance, wait for instructions. To replace the battery, refer to meet specifications until the battery gauge reads empty (Y or b). 744 Users Manual Battery Life The calibrator senses which battery is time to appear before you charge the battery. Table 4 shows the typical operating time for a low battery symbol b, that...
... battery life and best performance, wait for instructions. To replace the battery, refer to meet specifications until the battery gauge reads empty (Y or b). 744 Users Manual Battery Life The calibrator senses which battery is time to appear before you charge the battery. Table 4 shows the typical operating time for a low battery symbol b, that...
Fluke 744 Users Manual
Page 34
...and time can also control the format used for example in five languages. Selecting the Display Language The calibrator displays information in Setup mode, use the optional Fluke Model BE9005 Battery Eliminator to highlight your choice. The language you choose is available, you can be ...being used , the battery is applied to exit Setup mode. Press uor d to conserve battery power. You can be removed from the calibrator. 744 Users Manual Where ac power is the power-up default. 7. Press d three times. 4. When the battery eliminator is used to display the date ...
...and time can also control the format used for example in five languages. Selecting the Display Language The calibrator displays information in Setup mode, use the optional Fluke Model BE9005 Battery Eliminator to highlight your choice. The language you choose is available, you can be ...being used , the battery is applied to exit Setup mode. Press uor d to conserve battery power. You can be removed from the calibrator. 744 Users Manual Where ac power is the power-up default. 7. Press d three times. 4. When the battery eliminator is used to display the date ...
Fluke 744 Users Manual
Page 108
...Calibration Manual (PN 602505). Spent batteries should be disposed of replaceable parts is included with the solid waste stream. To order a replacement battery, order Model BP7235 Nickel-Metal Hydride or Model BP7217 NickelCadmium Battery Pack. An IBM PCTM-compatible personal computer, Microsoft Windows, and Fluke... the battery pack when it no longer holds a charge for recycling information. 98 Contact your authorized Fluke Service Center for the rated interval. 744 Users Manual Communicating with a PC You can upload and download procedures and saved results to the DPC/TRACK Users...
...Calibration Manual (PN 602505). Spent batteries should be disposed of replaceable parts is included with the solid waste stream. To order a replacement battery, order Model BP7235 Nickel-Metal Hydride or Model BP7217 NickelCadmium Battery Pack. An IBM PCTM-compatible personal computer, Microsoft Windows, and Fluke... the battery pack when it no longer holds a charge for recycling information. 98 Contact your authorized Fluke Service Center for the rated interval. 744 Users Manual Communicating with a PC You can upload and download procedures and saved results to the DPC/TRACK Users...
Fluke 744 Users Manual
Page 109
... the u and d keys to the 74X Series Calibration Manual (PN 602505). The CAL. Calibration of the 744 is not maladjusted. When in Setup mode. If the display is blank or unreadable, but the beeper works when you need to an authorized Fluke service center listed at the next calibration interval as a preventive maintenance procedure. STATUS number...
... the u and d keys to the 74X Series Calibration Manual (PN 602505). The CAL. Calibration of the 744 is not maladjusted. When in Setup mode. If the display is blank or unreadable, but the beeper works when you need to an authorized Fluke service center listed at the next calibration interval as a preventive maintenance procedure. STATUS number...
Fluke 744 Users Manual
Page 113
... Pneumatic test pump • 700HTP Hydraulic test pump • Fluke-700TC1 TC miniplug kit • Fluke-700TC2 TC miniplug kit Documenting Process Calibrator Accessories • C781 Soft Carrying Case • C789 Soft Carrying... Case • C700 Hard Carrying Case • BE9005 Series Battery Eliminator for bench-top use • BP7235 NiMH Battery Pack • BP7217 Ni-Cd Battery Pack • BC7217 Battery Charger • 74X Series Calibration Manual...
... Pneumatic test pump • 700HTP Hydraulic test pump • Fluke-700TC1 TC miniplug kit • Fluke-700TC2 TC miniplug kit Documenting Process Calibrator Accessories • C781 Soft Carrying Case • C789 Soft Carrying... Case • C700 Hard Carrying Case • BE9005 Series Battery Eliminator for bench-top use • BP7235 NiMH Battery Pack • BP7217 Ni-Cd Battery Pack • BC7217 Battery Charger • 74X Series Calibration Manual...