Fluke 741B, 743B, and 744 Process Calibrator Datasheet
Page 1
...; Protected against dirt, dust, and moisture; Ordering information Fluke-741B Documenting Process Calibrator Fluke-743B Documenting Process Calibrator Fluke-744 Documenting Process Calibrator For more information, go to calibrate, maintain, and troubleshoot HART instrumentation. Summary specifications: best case, midrange, one -year for pressure modules) 744: Get HART-ability The Fluke 744 offers all the capabilities of the 741B plus...
...; Protected against dirt, dust, and moisture; Ordering information Fluke-741B Documenting Process Calibrator Fluke-743B Documenting Process Calibrator Fluke-744 Documenting Process Calibrator For more information, go to calibrate, maintain, and troubleshoot HART instrumentation. Summary specifications: best case, midrange, one -year for pressure modules) 744: Get HART-ability The Fluke 744 offers all the capabilities of the 741B plus...
Fluke 744 Users Manual
Page 11
... and sourcing functions provided by the calibrator is unstable. A thermocouple (TC) input/output jack and internal isothermal block with HART-capable transmitters. A summary of the manual. Or, you troubleshoot, calibrate, verify, and document your work on how to...manually enter an external temperature reference. Refer to the 744 HART® Mode Users Guide for instructions on process instruments. The ability to use the HART communication feature. Documenting Process Calibrator Introduction The Fluke 744 Documenting Process Calibrator (hereafter referred to as the calibrator...
... and sourcing functions provided by the calibrator is unstable. A thermocouple (TC) input/output jack and internal isothermal block with HART-capable transmitters. A summary of the manual. Or, you troubleshoot, calibrate, verify, and document your work on how to...manually enter an external temperature reference. Refer to the 744 HART® Mode Users Guide for instructions on process instruments. The ability to use the HART communication feature. Documenting Process Calibrator Introduction The Fluke 744 Documenting Process Calibrator (hereafter referred to as the calibrator...
Fluke 744 Users Manual
Page 13
...; TL24 industrial test leads (two sets) • AC20 test clips (two sets) • TP20 test probes (one set) • HART interface cable • BP7235 rechargeable nickel-metal hydride pack • BC7217 battery charger with Instruction Sheet • Adjustable quick-release strap (PN ...measurement connections (two included, PN 944632) Documenting Process Calibrator Standard Equipment • 744 Users Manual English (PN 691287) French (PN 691300) German (PN 691311) Italian (PN 691318) Spanish (PN 691303) • 744 HART® Mode Users Guide English (PN 691292) French (PN 691326) German ...
...; TL24 industrial test leads (two sets) • AC20 test clips (two sets) • TP20 test probes (one set) • HART interface cable • BP7235 rechargeable nickel-metal hydride pack • BC7217 battery charger with Instruction Sheet • Adjustable quick-release strap (PN ...measurement connections (two included, PN 944632) Documenting Process Calibrator Standard Equipment • 744 Users Manual English (PN 691287) French (PN 691300) German (PN 691311) Italian (PN 691318) Spanish (PN 691303) • 744 HART® Mode Users Guide English (PN 691292) French (PN 691326) German ...
Fluke 744 Users Manual
Page 16
Standard Equipment (cont) ot02f.eps 6 744 Users Manual BC7217 Battery Charger BP7235 Nickel-Metal Hydride Battery Pack HART Mode Users Guide Users Manual HART Interface Cable Figure 1.
Standard Equipment (cont) ot02f.eps 6 744 Users Manual BC7217 Battery Charger BP7235 Nickel-Metal Hydride Battery Pack HART Mode Users Guide Users Manual HART Interface Cable Figure 1.
Fluke 744 Users Manual
Page 25
... off. 6 p key Selects the pressure measurement or sourcing function. 7 t key Selects TC (thermocouple) or RTD (resistance temperature detector) measurement or sourcing functions. 8 r key Toggles between HART communication mode and analog operation.
... off. 6 p key Selects the pressure measurement or sourcing function. 7 t key Selects TC (thermocouple) or RTD (resistance temperature detector) measurement or sourcing functions. 8 r key Toggles between HART communication mode and analog operation.
Fluke 744 Users Manual
Page 78
... simulate a thermocouple and measure the corresponding output current. 2. When the calibrator is in simultaneous MEASURE/SOURCE mode, a built-in HART interface, you use this case the calibrator is calibrated.) The calibrator runs preloaded tasks (procedures) that follows. Switch tests. Use the... the condition of a thermocouple and measuring the resulting current from the transmitter. 744 Users Manual Calibrating a Process Instrument Note To calibrate a HART-capable transmitter using a host computer and compatible application software. Enter a source value, for instructions.
... simulate a thermocouple and measure the corresponding output current. 2. When the calibrator is in simultaneous MEASURE/SOURCE mode, a built-in HART interface, you use this case the calibrator is calibrated.) The calibrator runs preloaded tasks (procedures) that follows. Switch tests. Use the... the condition of a thermocouple and measuring the resulting current from the transmitter. 744 Users Manual Calibrating a Process Instrument Note To calibrate a HART-capable transmitter using a host computer and compatible application software. Enter a source value, for instructions.
Fluke 744 Users Manual
Page 136
... frequency, 28 pressure, 30 resistance, 28 temperature with thermocouples, 34 voltage, 28 Memory, 81 reviewing, 83 Min and Max measurement display, 86 -N- HART mode, 1, 68 -J- Ramping the output, 62 Repair, 100 Replacement parts, 101 Resistance measuring, 28 sourcing, 46 Results saving, 81 RTD simulating,... 56 types, 34 RTD (Resistance-temperature Detectors), 37 744 Users Manual format, 24 Display, 17 Display language selecting, 24 -F- Name field in setup, 26 Ni-Cd battery, 22 -P- Key functions, ...
... frequency, 28 pressure, 30 resistance, 28 temperature with thermocouples, 34 voltage, 28 Memory, 81 reviewing, 83 Min and Max measurement display, 86 -N- HART mode, 1, 68 -J- Ramping the output, 62 Repair, 100 Replacement parts, 101 Resistance measuring, 28 sourcing, 46 Results saving, 81 RTD simulating,... 56 types, 34 RTD (Resistance-temperature Detectors), 37 744 Users Manual format, 24 Display, 17 Display language selecting, 24 -F- Name field in setup, 26 Ni-Cd battery, 22 -P- Key functions, ...
Fluke 744 Users Manual
Page 137
... for measure, 41, 42 temperature, 34, 39 Scale softkey, 41 Servicing, 100 Simulating, 55 loop power, 48 thermocouples, 55 Simultaneous measure/source, 65 Smart transmitters, HART, 1, 68 Source mode, 46 Source mode, 46 Sourcing current, 46 electrical parameters, 46 frequency, 46 loop power, 50 pressure, 52 resistance, 46 thermocouples, 55 voltage...
... for measure, 41, 42 temperature, 34, 39 Scale softkey, 41 Servicing, 100 Simulating, 55 loop power, 48 thermocouples, 55 Simultaneous measure/source, 65 Smart transmitters, HART, 1, 68 Source mode, 46 Source mode, 46 Sourcing current, 46 electrical parameters, 46 frequency, 46 loop power, 50 pressure, 52 resistance, 46 thermocouples, 55 voltage...