Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet
Page 1
... seconds. 3Voltage frequency is specified from 2 Hz to measurement Category III 1000 V and Category IV 600 V. The Fluke 179 comes with TL75 test leads, 9 V battery (installed), and manual. Waveform Normal sine wave Non True-rms meter Correct True-rms meter Correct Square Reads wave 10 % high Correct ... 44 80T-IR See page 42 80I-400 See page 40 Fluke 73 Included accessories Every Fluke 170 Series meter comes packaged with an 80BK Temperature Probe. Battery life: 200 hours typical for maintenance, field service and bench repair. The 170 Series have the features needed to...
... seconds. 3Voltage frequency is specified from 2 Hz to measurement Category III 1000 V and Category IV 600 V. The Fluke 179 comes with TL75 test leads, 9 V battery (installed), and manual. Waveform Normal sine wave Non True-rms meter Correct True-rms meter Correct Square Reads wave 10 % high Correct ... 44 80T-IR See page 42 80I-400 See page 40 Fluke 73 Included accessories Every Fluke 170 Series meter comes packaged with an 80BK Temperature Probe. Battery life: 200 hours typical for maintenance, field service and bench repair. The 170 Series have the features needed to...
Fluke Multimeters - Anatomy of a High Quality Meter Application Note
Page 2
... +1 (425) 446-5116 Web access: http://www.fluke.com Transient test values for finger guards and rubber molded grips to . This verifies that reason could save your life. tion equipment • Outside and service entrance, service drop from CAT III source • Outlets at the... is made to an appropriately low level • Any high-voltage-low-energy source derived from CAT IV source Category III - Manuals actually are designed with high-quality, safety-rated accessories. sible. typically covers electronic equipment • Protected electronic equipment • Equipment...
... +1 (425) 446-5116 Web access: http://www.fluke.com Transient test values for finger guards and rubber molded grips to . This verifies that reason could save your life. tion equipment • Outside and service entrance, service drop from CAT III source • Outlets at the... is made to an appropriately low level • Any high-voltage-low-energy source derived from CAT IV source Category III - Manuals actually are designed with high-quality, safety-rated accessories. sible. typically covers electronic equipment • Protected electronic equipment • Equipment...
Fluke Precision Multimeters - Understanding Specifications for Precision Multimeters Application Note
Page 2
...calculate the mean 99.7 % of the readings will record a narrow spread of the readings will be traceable to any input in the DMM service manual. • The calibrator was within the specification, especially toward the beginning of spec between the DMM and national standards, including calibrators...9400 9.9600 9.9800 10.0000 10.0200 10.0400 10.0600 10.0800 Figure 1: A normal distribution with simple instruments like the Fluke 5700A or Fluke 9100. Traceability and specifications So far we have not discussed how we make sure we're all the measurements, which corresponds...
...calculate the mean 99.7 % of the readings will record a narrow spread of the readings will be traceable to any input in the DMM service manual. • The calibrator was within the specification, especially toward the beginning of spec between the DMM and national standards, including calibrators...9400 9.9600 9.9800 10.0000 10.0200 10.0400 10.0600 10.0800 Figure 1: A normal distribution with simple instruments like the Fluke 5700A or Fluke 9100. Traceability and specifications So far we have not discussed how we make sure we're all the measurements, which corresponds...
FE 175,177,179 Users Manual
Page 4
...might be impaired. ⇒ Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. see manual b Battery (Low battery when shown on display.) Inspected and licensed by measuring a known voltage. ⇒ Do not apply more than the rated voltage,... the Meter case or battery door. These voltages pose a shock hazard. ⇒ Replace the battery as soon as specified in doubt, have the Meter serviced. ⇒ Always use the Meter around explosive gas or vapor. ⇒ When using the test leads, keep your fingers behind the finger guards. ⇒...
...might be impaired. ⇒ Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. see manual b Battery (Low battery when shown on display.) Inspected and licensed by measuring a known voltage. ⇒ Do not apply more than the rated voltage,... the Meter case or battery door. These voltages pose a shock hazard. ⇒ Replace the battery as soon as specified in doubt, have the Meter serviced. ⇒ Always use the Meter around explosive gas or vapor. ⇒ When using the test leads, keep your fingers behind the finger guards. ⇒...
FE 175,177,179 Users Manual
Page 5
...is momentarily displayed when you to IV) based on the magnitude of data. This manual applies to protect against transients in fixed-equipment installations at : register.fluke.com Models 175, 177 & 179 True RMS Multimeters "Warning" and "Caution" Statements A " XWWarning" identifies hazardous ... display and a bar graph. XW Warning Attempting to or from the primary supply level (overhead or underground utility service). The Fluke Model 175, Model 177, and Model 179 are batterypowered, true-RMS multimeters (hereafter "the Meter") with a test lead in an incorrect terminal might blow ...
...is momentarily displayed when you to IV) based on the magnitude of data. This manual applies to protect against transients in fixed-equipment installations at : register.fluke.com Models 175, 177 & 179 True RMS Multimeters "Warning" and "Caution" Statements A " XWWarning" identifies hazardous ... display and a bar graph. XW Warning Attempting to or from the primary supply level (overhead or underground utility service). The Fluke Model 175, Model 177, and Model 179 are batterypowered, true-RMS multimeters (hereafter "the Meter") with a test lead in an incorrect terminal might blow ...
FE 175,177,179 Users Manual
Page 7
...Voltage ≥ 30 V, or voltage overload (OL) Display HOLD is present on the capacitor being tested. MIN MAX AVG enabled. Low battery. Manual Range The user selects the range. 13 ± Bar graph polarity. 14 0L 15 LEAd WThe input out of range. Invalid EEPROM data.... In the capacitance function, too much electrical charge is enabled. Have Meter serviced. Display . 5 6 4 3 2 1 7 8 7 9 13 12 11 14 10 15 No. 1 2 OSymbol s h3 K 4 Y 5 6 Amh MAX , MIN, AVG AIK02F.EPS Meaning Continuity test. Diode...
...Voltage ≥ 30 V, or voltage overload (OL) Display HOLD is present on the capacitor being tested. MIN MAX AVG enabled. Low battery. Manual Range The user selects the range. 13 ± Bar graph polarity. 14 0L 15 LEAd WThe input out of range. Invalid EEPROM data.... In the capacitance function, too much electrical charge is enabled. Have Meter serviced. Display . 5 6 4 3 2 1 7 8 7 9 13 12 11 14 10 15 No. 1 2 OSymbol s h3 K 4 Y 5 6 Amh MAX , MIN, AVG AIK02F.EPS Meaning Continuity test. Diode...