Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet
Page 1
... accuracy 177; 0.09 % (Models 177 and 179) 177; 0.15 % (Model 175) 177; 1.0 % of reading 177; 1.0 % of reading 177; 1.5 % of reading 177; 0.9 % of reading 177; 1.2 % of reading 177; 0.1 % of reading 1.0 % of reading 1All ac voltage and ac current ranges are protected to freeze the measurement display. Ordering information Fluke-175 Digital Multimeter Fluke-177 Digital Multimeter Fluke-179 Digital Multimeter Fluke-73-3 Digital Multimeter Fluke-77...
... accuracy 177; 0.09 % (Models 177 and 179) 177; 0.15 % (Model 175) 177; 1.0 % of reading 177; 1.0 % of reading 177; 1.5 % of reading 177; 0.9 % of reading 177; 1.2 % of reading 177; 0.1 % of reading 1.0 % of reading 1All ac voltage and ac current ranges are protected to freeze the measurement display. Ordering information Fluke-175 Digital Multimeter Fluke-177 Digital Multimeter Fluke-179 Digital Multimeter Fluke-73-3 Digital Multimeter Fluke-77...
FE 175,177,179 Users Manual
Page 1
All rights reserved. Printed in USA. ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation.
All rights reserved. Printed in USA. ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation.
FE 175,177,179 Users Manual
Page 3
Table of Contents Title Page Contacting Fluke ...1 "Warning" and "Caution" Statements 1 Unsafe Voltage...1 Test Lead Alert ...1 Battery Saver ("Sleep Mode 2 Terminals ...2 Rotary Switch Positions...2 Display ...3 MIN MAX AVG Recording Mode 4 Display HOLD and AutoHOLD Modes 4 YELLOW Button ...4 Display Backlight (Model 177 and 179 Only 4 Manual Ranging and Autoranging 5 Power-Up Options ...5 Making Basic...
Table of Contents Title Page Contacting Fluke ...1 "Warning" and "Caution" Statements 1 Unsafe Voltage...1 Test Lead Alert ...1 Battery Saver ("Sleep Mode 2 Terminals ...2 Rotary Switch Positions...2 Display ...3 MIN MAX AVG Recording Mode 4 Display HOLD and AutoHOLD Modes 4 YELLOW Button ...4 Display Backlight (Model 177 and 179 Only 4 Manual Ranging and Autoranging 5 Power-Up Options ...5 Making Basic...
FE 175,177,179 Users Manual
Page 5
... Y symbol is momentarily displayed when you to make a measurement with a 6000-count, 3 3/4-digit display and a bar graph. The Fluke Model 175, Model 177, and Model 179 are designed to all three models. CAT III meters are in Singapore +1-425-446-5500 from the mA or A ...IV meters are batterypowered, true-RMS multimeters (hereafter "the Meter") with a test lead in fixed-equipment installations at : register.fluke.com Models 175, 177 & 179 True RMS Multimeters "Warning" and "Caution" Statements A " XWWarning" identifies hazardous conditions and actions that could cause bodily harm...
... Y symbol is momentarily displayed when you to make a measurement with a 6000-count, 3 3/4-digit display and a bar graph. The Fluke Model 175, Model 177, and Model 179 are designed to all three models. CAT III meters are in Singapore +1-425-446-5500 from the mA or A ...IV meters are batterypowered, true-RMS multimeters (hereafter "the Meter") with a test lead in fixed-equipment installations at : register.fluke.com Models 175, 177 & 179 True RMS Multimeters "Warning" and "Caution" Statements A " XWWarning" identifies hazardous conditions and actions that could cause bodily harm...
FE 175,177,179 Users Manual
Page 14
Test fuses as shown below. Models 175, 177 & 179 Users Manual Cleaning Wipe the case with a damp cloth and mild detergent. XW Testing the Fuses Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse. HOLD MINMAX RANGE 440 mA 11 A Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings.
Test fuses as shown below. Models 175, 177 & 179 Users Manual Cleaning Wipe the case with a damp cloth and mild detergent. XW Testing the Fuses Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse. HOLD MINMAX RANGE 440 mA 11 A Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings.