EMC PowerEdge RAID Controller S140 Users Guide
Page 10
...; PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 • PowerEdge R640 • PowerEdge R740 • PowerEdge R740xd • PowerEdge R740xd2 • PowerEdge R840 • PowerEdge R940 • PowerEdge R940xa • PowerEdge R6415 • PowerEdge R7425 • PowerEdge R7415 • PowerEdge T140 • PowerEdge T340 • PowerEdge T440 • PowerEdge T640 • PowerEdge XE2420 Supported physical disks The PERC S140 controller supports the following operating systems: NOTE: See Dell...
...; PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 • PowerEdge R640 • PowerEdge R740 • PowerEdge R740xd • PowerEdge R740xd2 • PowerEdge R840 • PowerEdge R940 • PowerEdge R940xa • PowerEdge R6415 • PowerEdge R7425 • PowerEdge R7415 • PowerEdge T140 • PowerEdge T340 • PowerEdge T440 • PowerEdge T640 • PowerEdge XE2420 Supported physical disks The PERC S140 controller supports the following operating systems: NOTE: See Dell...
Direct from Development - PowerEdge 14th Generation 1 Socket Servers
Page 1
...socket servers help users simplify their IT, improve productivity and grow into the future. or its subsidiaries The four new servers, the PowerEdge T140, T340, R240 and R340, feature several new internal technologies as well as expanded internal storage capacity: Memory technology supporting 2666...security will enable businesses to deliver high, balanced performance and reliable operation. Both are Intel's new Xeon E-2100 processors. The combination of Dell Inc. Thus, each of these new servers is implemented in the new servers, up 11% from the 2400 MT/s used with more...
...socket servers help users simplify their IT, improve productivity and grow into the future. or its subsidiaries The four new servers, the PowerEdge T140, T340, R240 and R340, feature several new internal technologies as well as expanded internal storage capacity: Memory technology supporting 2666...security will enable businesses to deliver high, balanced performance and reliable operation. Both are Intel's new Xeon E-2100 processors. The combination of Dell Inc. Thus, each of these new servers is implemented in the new servers, up 11% from the 2400 MT/s used with more...
Direct from Development - PowerEdge 14th Generation 1 Socket Servers
Page 2
...as 7 as well. While each of large organizations as the business grows. Dell, EMC and other trademarks are on a stable platform Enhanced high availability features can result in the R240). The T140 has a mini-tower form factor and typically goes to small office / ... about high availability and serviceability are optimized for different use cases and environments: PowerEdge T140: This is well-suited for single-tier workloads and offers room for expansion. or its subsidiaries PowerEdge Product Group Direct from older, installed servers to the new technologies: ...
...as 7 as well. While each of large organizations as the business grows. Dell, EMC and other trademarks are on a stable platform Enhanced high availability features can result in the R240). The T140 has a mini-tower form factor and typically goes to small office / ... about high availability and serviceability are optimized for different use cases and environments: PowerEdge T140: This is well-suited for single-tier workloads and offers room for expansion. or its subsidiaries PowerEdge Product Group Direct from older, installed servers to the new technologies: ...
EMC Technical Specifications
Page 1
Dell EMC PowerEdge T140 Technical Specifications Regulatory Model: E59S Series Regulatory Type: E59S001 June 2020 Rev. A06
Dell EMC PowerEdge T140 Technical Specifications Regulatory Model: E59S Series Regulatory Type: E59S001 June 2020 Rev. A06
EMC Technical Specifications
Page 3
Contents 1 Dell EMC PowerEdge T140 system overview 4 Front view of the system...5 Rear view of the system...6 2 Technical specifications...7 Chassis dimensions...7 System weight...8 Processor specifications...8 PSU ...redundant cabled power supply unit indicator codes 16 PowerEdge T140 system diagnostics...16 Dell Embedded System Diagnostics...17 4 Getting help...18 Recycling or End-of-Life service information...18 Contacting Dell...18 Accessing system information by using QRL...18 Quick Resource Locator for Dell EMC PowerEdge T140 system 19 Receiving automated support with SupportAssist ...
Contents 1 Dell EMC PowerEdge T140 system overview 4 Front view of the system...5 Rear view of the system...6 2 Technical specifications...7 Chassis dimensions...7 System weight...8 Processor specifications...8 PSU ...redundant cabled power supply unit indicator codes 16 PowerEdge T140 system diagnostics...16 Dell Embedded System Diagnostics...17 4 Getting help...18 Recycling or End-of-Life service information...18 Contacting Dell...18 Accessing system information by using QRL...18 Quick Resource Locator for Dell EMC PowerEdge T140 system 19 Receiving automated support with SupportAssist ...
EMC Technical Specifications
Page 4
... view of the system • Rear view of SAS, SATA drives, and SSDs are referred to four 3.5-inch cabled SAS or SATA drives. 1 Dell EMC PowerEdge T140 system overview The Dell EMC PowerEdge T140 system is a tower server that supports: • One Intel Xeon, Core i3, Pentium, or Celeron processor • Four DIMM slots • Cabled... • Up to as drives in this document, unless specified otherwise. For more information, see the Technical specifications section. NOTE: All instances of the system 4 Dell EMC PowerEdge T140 system overview
... view of the system • Rear view of SAS, SATA drives, and SSDs are referred to four 3.5-inch cabled SAS or SATA drives. 1 Dell EMC PowerEdge T140 system overview The Dell EMC PowerEdge T140 system is a tower server that supports: • One Intel Xeon, Core i3, Pentium, or Celeron processor • Four DIMM slots • Cabled... • Up to as drives in this document, unless specified otherwise. For more information, see the Technical specifications section. NOTE: All instances of the system 4 Dell EMC PowerEdge T140 system overview
EMC Technical Specifications
Page 5
Front view of the system Figure 1. Optical drive (optional) 2. Power button 3. iDRAC direct micro USB port For more information about the ports, see the Ports and connectors specifications section. Front view of the system 1. Dell EMC PowerEdge T140 system overview 5 USB 3.0 port 5. System health and ID indicator 4.
Front view of the system Figure 1. Optical drive (optional) 2. Power button 3. iDRAC direct micro USB port For more information about the ports, see the Ports and connectors specifications section. Front view of the system 1. Dell EMC PowerEdge T140 system overview 5 USB 3.0 port 5. System health and ID indicator 4.
EMC Technical Specifications
Page 6
... port 14. PSU Built-in Self Test (BIST) Button NOTE: For more information about the ports and connectors, see the Ports and connectors specifications section. 6 Dell EMC PowerEdge T140 system overview PSU Built-in Self Test (BIST) LED 2. USB 3.0 ports (2) 11. iDRAC MAC address and iDRAC secure password label 4. Rear view of the...
... port 14. PSU Built-in Self Test (BIST) Button NOTE: For more information about the ports and connectors, see the Ports and connectors specifications section. 6 Dell EMC PowerEdge T140 system overview PSU Built-in Self Test (BIST) LED 2. USB 3.0 ports (2) 11. iDRAC MAC address and iDRAC secure password label 4. Rear view of the...
EMC Technical Specifications
Page 7
Chassis dimensions Table 1. Dell EMC PowerEdge T140 system dimensions Xa Xb Ya Yb Za Zb Zc 175 mm (6.89 NA inches) 360 mm (14.17 inches) 362.9 mm (14.29 With bezel: ...
Chassis dimensions Table 1. Dell EMC PowerEdge T140 system dimensions Xa Xb Ya Yb Za Zb Zc 175 mm (6.89 NA inches) 360 mm (14.17 inches) 362.9 mm (14.29 With bezel: ...
EMC Technical Specifications
Page 8
...IT power systems with all drives) 11.84 kg (26.10 lb) Processor specifications Table 3. Cooling fan specifications The Dell EMC PowerEdge T140 system supports the following: • One system cooling fan located at the back of processors supported Intel Xeon processor E-2200...Core i3 8100 processor Intel Pentium G5500 processor Intel Celeron G4900 processor PSU specifications The Dell EMC PowerEdge T140 system supports up to -phase voltage not exceeding 240 V. Table 1. Table 4. Dell EMC PowerEdge T140 system dimensions Xa Xb Ya Yb Za Zb Zc Without bezel: NA System weight...
...IT power systems with all drives) 11.84 kg (26.10 lb) Processor specifications Table 3. Cooling fan specifications The Dell EMC PowerEdge T140 system supports the following: • One system cooling fan located at the back of processors supported Intel Xeon processor E-2200...Core i3 8100 processor Intel Pentium G5500 processor Intel Celeron G4900 processor PSU specifications The Dell EMC PowerEdge T140 system supports up to -phase voltage not exceeding 240 V. Table 1. Table 4. Dell EMC PowerEdge T140 system dimensions Xa Xb Ya Yb Za Zb Zc Without bezel: NA System weight...
EMC Technical Specifications
Page 9
... 64 GB Memory module sockets Four 288-pin Speed 2666 MT/s 2400 MT/s 2133 MT/s Storage controller specifications The Dell EMC PowerEdge T140 system supports the following memory specifications for optimized operation: Table 6. NOTE: When selecting or upgrading the system configuration,... to four PCI express (PCIe) Generation 3. Memory specifications The Dell EMC PowerEdge T140 system supports the following controller cards: Table 7. Expansion card slots supported on the system board PCIe slot Slot 1 (...
... 64 GB Memory module sockets Four 288-pin Speed 2666 MT/s 2400 MT/s 2133 MT/s Storage controller specifications The Dell EMC PowerEdge T140 system supports the following memory specifications for optimized operation: Table 6. NOTE: When selecting or upgrading the system configuration,... to four PCI express (PCIe) Generation 3. Memory specifications The Dell EMC PowerEdge T140 system supports the following controller cards: Table 7. Expansion card slots supported on the system board PCIe slot Slot 1 (...
EMC Technical Specifications
Page 10
... supports the following optical drives. Serial connector specifications The Dell EMC PowerEdge T140 system supports one 15-pin VGA port, on the back panel. VGA ports specification The Dell EMC PowerEdge T140 system supports one serial connector on the back panel, which is required for iDRAC Direct...USB 3.0-compliant ports • Four USB 2.0-compliant ports Internal USB • One internal USB 3.0-compliant port NIC ports specifications The Dell EMC PowerEdge T140 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports that are located on the back of drives...
... supports the following optical drives. Serial connector specifications The Dell EMC PowerEdge T140 system supports one 15-pin VGA port, on the back panel. VGA ports specification The Dell EMC PowerEdge T140 system supports one serial connector on the back panel, which is required for iDRAC Direct...USB 3.0-compliant ports • Four USB 2.0-compliant ports Internal USB • One internal USB 3.0-compliant port NIC ports specifications The Dell EMC PowerEdge T140 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports that are located on the back of drives...
EMC Technical Specifications
Page 11
... pulse on each side of the system) of 71 G for up to 95% RH with 29°C (84.2°F) maximum dew point. Video specifications The Dell EMC PowerEdge T140 system supports Matrox G200eR2 graphics card with the Manuals & Documents on www...
... pulse on each side of the system) of 71 G for up to 95% RH with 29°C (84.2°F) maximum dew point. Video specifications The Dell EMC PowerEdge T140 system supports Matrox G200eR2 graphics card with the Manuals & Documents on www...
EMC Technical Specifications
Page 15
...Figure 4. Blinking blue Indicates that the system ID mode is experiencing a fault. If the problem persists, see the Error Code Lookup page at qrl.dell.com NIC indicator codes Each NIC on , system is healthy, and system ID mode is flowing through the NIC, and the link LED indicator ... Topics: • System health and system ID indicator codes • NIC indicator codes • Non-redundant cabled power supply unit indicator codes • PowerEdge T140 system diagnostics System health and system ID indicator codes The system health and system ID indicator is in fail-safe mode.
...Figure 4. Blinking blue Indicates that the system ID mode is experiencing a fault. If the problem persists, see the Error Code Lookup page at qrl.dell.com NIC indicator codes Each NIC on , system is healthy, and system ID mode is flowing through the NIC, and the link LED indicator ... Topics: • System health and system ID indicator codes • NIC indicator codes • Non-redundant cabled power supply unit indicator codes • PowerEdge T140 system diagnostics System health and system ID indicator codes The system health and system ID indicator is in fail-safe mode.
EMC Technical Specifications
Page 16
...or received. AC PSU status indicator Table 24. Green A valid power source is connected to test your system, run the system diagnostics before contacting Dell for technical assistance. Link indicator is green, and activity indicator is operational. Condition The NIC is being sent or received. Figure 6. Self-diagnostic button... being sent or received. The NIC is connected to the network. Non-redundant cabled AC PSU status indicator and self-diagnostic button 1. PowerEdge T140 system diagnostics If you solve the problem. 16 System diagnostics and indicator codes
...or received. AC PSU status indicator Table 24. Green A valid power source is connected to test your system, run the system diagnostics before contacting Dell for technical assistance. Link indicator is green, and activity indicator is operational. Condition The NIC is being sent or received. Figure 6. Self-diagnostic button... being sent or received. The NIC is connected to the network. Non-redundant cabled AC PSU status indicator and self-diagnostic button 1. PowerEdge T140 system diagnostics If you solve the problem. 16 System diagnostics and indicator codes
EMC Technical Specifications
Page 18
... Technical Support b. If you can use the Quick Resource Locator (QRL) located on the information tag in the front of the T140, to access the information about the Dell EMC PowerEdge T140. To contact Dell for this product in your area. For customized support: a. Accessing system information by country and product, and some services may...
... Technical Support b. If you can use the Quick Resource Locator (QRL) located on the information tag in the front of the T140, to access the information about the Dell EMC PowerEdge T140. To contact Dell for this product in your area. For customized support: a. Accessing system information by country and product, and some services may...
EMC Technical Specifications
Page 19
... uploads it securely to troubleshoot the issue. • Proactive contact - Quick Resource Locator for Dell EMC PowerEdge T140 system Receiving automated support with Dell EMC Technical Support. • Automated diagnostic collection - By installing and setting up a SupportAssist application in your Dell EMC devices and automatically detects hardware issues, both proactively and predictively. • Automated case...
... uploads it securely to troubleshoot the issue. • Proactive contact - Quick Resource Locator for Dell EMC PowerEdge T140 system Receiving automated support with Dell EMC Technical Support. • Automated diagnostic collection - By installing and setting up a SupportAssist application in your Dell EMC devices and automatically detects hardware issues, both proactively and predictively. • Automated case...
EMC Installation and Service Manual
Page 1
Dell EMC PowerEdge T140 Installation and Service Manual Regulatory Model: E59S Series Regulatory Type: E59S001 June 2020 Rev. A06
Dell EMC PowerEdge T140 Installation and Service Manual Regulatory Model: E59S Series Regulatory Type: E59S001 June 2020 Rev. A06
EMC Installation and Service Manual
Page 3
Contents 1 About this document...7 2 Dell EMC PowerEdge T140 system overview 8 Front view of the system...9 Rear view of the system...10 Inside the system...11 Locating the information tag of your system...11 System Information Label...12 3 PowerEdge T140 initial system setup and configuration 15 Setting...utility...35 Device Settings...35 Dell Lifecycle Controller...35 Embedded system management...35 Boot Manager...36 Viewing Boot Manager...36 Boot Manager main menu...36 One-shot UEFI boot menu...36 System Utilities...36 PXE boot...36 5 PowerEdge T140 installing and removing system components...
Contents 1 About this document...7 2 Dell EMC PowerEdge T140 system overview 8 Front view of the system...9 Rear view of the system...10 Inside the system...11 Locating the information tag of your system...11 System Information Label...12 3 PowerEdge T140 initial system setup and configuration 15 Setting...utility...35 Device Settings...35 Dell Lifecycle Controller...35 Embedded system management...35 Boot Manager...36 Viewing Boot Manager...36 Boot Manager main menu...36 One-shot UEFI boot menu...36 System Utilities...36 PXE boot...36 5 PowerEdge T140 installing and removing system components...
EMC Installation and Service Manual
Page 5
... and indicator codes 96 System health and system ID indicator codes...96 NIC indicator codes...96 Non-redundant cabled power supply unit indicator codes 97 PowerEdge T140 system diagnostics...97 Dell Embedded System Diagnostics...98 9 Getting help...99 Recycling or End-of-Life service information...99 Contents 5
... and indicator codes 96 System health and system ID indicator codes...96 NIC indicator codes...96 Non-redundant cabled power supply unit indicator codes 97 PowerEdge T140 system diagnostics...97 Dell Embedded System Diagnostics...98 9 Getting help...99 Recycling or End-of-Life service information...99 Contents 5