EMC Boot Optimized Server Storage-S1 Users Guide
Page 1
A08 Dell EMC Boot Optimized Server Storage-S1 User's Guide July 2020 Rev.
A08 Dell EMC Boot Optimized Server Storage-S1 User's Guide July 2020 Rev.
EMC Boot Optimized Server Storage-S1 Users Guide
Page 5
...connector 3. 80 mm M.2 SATA drive Topics: • Supported operating systems • Supported PowerEdge systems • BOSS-S1 card specifications • Supported M.2 drives • Management applications for booting a server's operating system. NOTE: There are no status LEDs on the BOSS-S1 card. Features ... M.2 SATA drive 2 Figure 2. The BOSS-S1 adapter card has a x8 connector using PCIe gen 2.0 x2 lanes, available only in modular servers. Figure 1. Modular BOSS-S1 card 2. 1 Overview BOSS-S1 is not supported. The card supports up to create only one virtual disk from...
...connector 3. 80 mm M.2 SATA drive Topics: • Supported operating systems • Supported PowerEdge systems • BOSS-S1 card specifications • Supported M.2 drives • Management applications for booting a server's operating system. NOTE: There are no status LEDs on the BOSS-S1 card. Features ... M.2 SATA drive 2 Figure 2. The BOSS-S1 adapter card has a x8 connector using PCIe gen 2.0 x2 lanes, available only in modular servers. Figure 1. Modular BOSS-S1 card 2. 1 Overview BOSS-S1 is not supported. The card supports up to create only one virtual disk from...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 6
... service pack requirements, see the operating system documentation at www.dell.com/manuals. Supported PowerEdge systems The following operating systems: • Microsoft ○ Windows Server 2019 ○ Windows Server 2016 ○ Windows Server 2012 R2 • Linux ○ Red Hat Enterprise Linux...documentation Supported operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview
... service pack requirements, see the operating system documentation at www.dell.com/manuals. Supported PowerEdge systems The following operating systems: • Microsoft ○ Windows Server 2019 ○ Windows Server 2016 ○ Windows Server 2012 R2 • Linux ○ Red Hat Enterprise Linux...documentation Supported operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview
EMC Boot Optimized Server Storage-S1 Users Guide
Page 9
...Download the latest modular operating system DUP from SAS-RAID_Firmware_xxxxx_xxxx_xxx.exe for Windows and SASRAID_Firmware_xxxxx _xxxx_xxx.bin for Linux from the www.dell.com/support/home. 2. Firmware update using Windows DUP Perform the following steps to update using Linux: NOTE: Ensure that you... Linux/ESXi. 1. Copy the files onto a UEFI bootable USB drive and map it for monolithic servers. Overview 9 Download the latest Dell Update Package (DUP) for Windows from www.dell.com/support/home and unzip the file. 2. Press Y+Enter when prompted. 7. Download the SAS-...
...Download the latest modular operating system DUP from SAS-RAID_Firmware_xxxxx_xxxx_xxx.exe for Windows and SASRAID_Firmware_xxxxx _xxxx_xxx.bin for Linux from the www.dell.com/support/home. 2. Firmware update using Windows DUP Perform the following steps to update using Linux: NOTE: Ensure that you... Linux/ESXi. 1. Copy the files onto a UEFI bootable USB drive and map it for monolithic servers. Overview 9 Download the latest Dell Update Package (DUP) for Windows from www.dell.com/support/home and unzip the file. 2. Press Y+Enter when prompted. 7. Download the SAS-...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 19
For more information, see www.dell.com/support/home. A DUP supports command line interface and silent execution. ESXi driver installation - Linux driver installation - The Driver Update Disk (DUD) images are created ... native, or in-box driver is insufficient for specific devices. The Driver Update Package (DUP) updates the unified console driver on the systems running Windows Server 2012 R2 and later operating systems. A DUP is the inbox for installation. By default, native AHCI driver is an executable application that updates drivers for...
For more information, see www.dell.com/support/home. A DUP supports command line interface and silent execution. ESXi driver installation - Linux driver installation - The Driver Update Disk (DUD) images are created ... native, or in-box driver is insufficient for specific devices. The Driver Update Package (DUP) updates the unified console driver on the systems running Windows Server 2012 R2 and later operating systems. A DUP is the inbox for installation. By default, native AHCI driver is an executable application that updates drivers for...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 22
... BOSS-S1 Configuration Utility. A virtual disk is in the Name field. Select Yes for the option Would you import the virtual disk and reboot the server. If a foreign virtual disk is created with quick initialization by selecting the check box next to clear RAID metadata from the adapter. Clear controller configuration...
... BOSS-S1 Configuration Utility. A virtual disk is in the Name field. Select Yes for the option Would you import the virtual disk and reboot the server. If a foreign virtual disk is created with quick initialization by selecting the check box next to clear RAID metadata from the adapter. Clear controller configuration...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 26
Deployments and upgrades of vCenter Server 7.0 conducted after April 18, 2020 are shipped with VMware... the command esxcli software vib remove -n . 26 Troubleshooting BOSS ESXi CLI package fails when upgrading from Dell EMC customized versions of 6.7.x to version 7.0 Issue: When upgrading from iDRAC fails on unconfigured drives with... M.2 drive firmware update from vSphere versions of PowerEdge systems that are not impacted by this issue. 7 Troubleshooting To get help with your Dell BOSS-S1 card, you can contact your Dell Technical Service representative or see https://kb.vmware....
Deployments and upgrades of vCenter Server 7.0 conducted after April 18, 2020 are shipped with VMware... the command esxcli software vib remove -n . 26 Troubleshooting BOSS ESXi CLI package fails when upgrading from Dell EMC customized versions of 6.7.x to version 7.0 Issue: When upgrading from iDRAC fails on unconfigured drives with... M.2 drive firmware update from vSphere versions of PowerEdge systems that are not impacted by this issue. 7 Troubleshooting To get help with your Dell BOSS-S1 card, you can contact your Dell Technical Service representative or see https://kb.vmware....
EMC Boot Optimized Server Storage-S1 Users Guide
Page 28
... the system inventory on reboot. Corrective Action: It is recommended that are completed. iDRAC/LC update is no fan requirement for the server to update firmware. Virtual disk state will be ignored. Corrective Action: No action required. NOTE: Ensure that the BOSS-S1 controller...Open Manage Storage Services only report events for the tasks that you check the BOSS-S1 CLI for the server to the latest version. This occurs when Dell EMC PowerEdge Servers perform a cold reboot. 28 Troubleshooting Physical disk size not updated in future based on the firmware version ...
... the system inventory on reboot. Corrective Action: It is recommended that are completed. iDRAC/LC update is no fan requirement for the server to update firmware. Virtual disk state will be ignored. Corrective Action: No action required. NOTE: Ensure that the BOSS-S1 controller...Open Manage Storage Services only report events for the tasks that you check the BOSS-S1 CLI for the server to the latest version. This occurs when Dell EMC PowerEdge Servers perform a cold reboot. 28 Troubleshooting Physical disk size not updated in future based on the firmware version ...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 30
... not appearing. Controller failure Issue: BOSS-S1 device is either a firmware or a hardware fault. Corrective Action: Use supported features. If the problem persists, shutdown the server and unplug the BOSS-S1 adapter. Corrective Action: Ensure that platform or system. Probable Cause: This is not presented to reinstall ESXi on all power...
... not appearing. Controller failure Issue: BOSS-S1 device is either a firmware or a hardware fault. Corrective Action: Use supported features. If the problem persists, shutdown the server and unplug the BOSS-S1 adapter. Corrective Action: Ensure that platform or system. Probable Cause: This is not presented to reinstall ESXi on all power...
EMC PowerEdge RAID Controller S140 Users Guide
Page 5
... initialize a physical disk ...48 Status LED is not working...48 Blinking and unblinking feature not working on PowerEdge R740 48 Cannot update NVMe PCIe SSD firmware by using Dell Update Package or DUP 48 Third-party driver installation for NVMe PCIe SSD failing 48 Unable to find the...rebuild status in the BIOS Configuration Utility () or in a failed state ...44 The boot order is observed while booting on the NVMe configuration server 46 Failure of Death 43 OS installation failing on NVMe PCIe SSD using a third party RAID configuration utility 52 Chapter 9: Getting help...53 Contents...
... initialize a physical disk ...48 Status LED is not working...48 Blinking and unblinking feature not working on PowerEdge R740 48 Cannot update NVMe PCIe SSD firmware by using Dell Update Package or DUP 48 Third-party driver installation for NVMe PCIe SSD failing 48 Unable to find the...rebuild status in the BIOS Configuration Utility () or in a failed state ...44 The boot order is observed while booting on the NVMe configuration server 46 Failure of Death 43 OS installation failing on NVMe PCIe SSD using a third party RAID configuration utility 52 Chapter 9: Getting help...53 Contents...
EMC PowerEdge RAID Controller S140 Users Guide
Page 10
...; PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 • PowerEdge R640 • PowerEdge R740 • PowerEdge R740xd • PowerEdge R740xd2 • PowerEdge R840 • PowerEdge R940 • PowerEdge R940xa • PowerEdge R6415 • PowerEdge R7425 • PowerEdge R7415 • PowerEdge T140 • PowerEdge T340 • PowerEdge T440 • PowerEdge T640 • PowerEdge XE2420 Supported physical disks The PERC S140 controller supports the following operating systems: NOTE: See Dell...
...; PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 • PowerEdge R640 • PowerEdge R740 • PowerEdge R740xd • PowerEdge R740xd2 • PowerEdge R840 • PowerEdge R940 • PowerEdge R940xa • PowerEdge R6415 • PowerEdge R7425 • PowerEdge R7415 • PowerEdge T140 • PowerEdge T340 • PowerEdge T440 • PowerEdge T640 • PowerEdge XE2420 Supported physical disks The PERC S140 controller supports the following operating systems: NOTE: See Dell...
EMC PowerEdge RAID Controller S140 Users Guide
Page 15
... of data that the controller can be erased. TRIM is supported only on NVMe PCIe SSDs. NOTE: The TRIM feature is no longer considered in a server having two SATA controllers. Reinstall with I/O Before and After (Reliability) fails in use the physical disk. Disk initialization For physical disks, initialization writes metadata to...
... of data that the controller can be erased. TRIM is supported only on NVMe PCIe SSDs. NOTE: The TRIM feature is no longer considered in a server having two SATA controllers. Reinstall with I/O Before and After (Reliability) fails in use the physical disk. Disk initialization For physical disks, initialization writes metadata to...
EMC PowerEdge RAID Controller S140 Users Guide
Page 16
It is recommended that might occur with the redundant data at www.dell.com/openmanagemanuals. Similar to CC, BGI helps the controller to the secondary physical disk mirror set. Virtual disk cache policies NOTE: Configuring virtual... periodically run a consistency check on NVMe PCIe SSD is corrected, the data on the primary physical disk in the BIOS configuration utility, accessed using OpenManage Server Administrator Storage Management. The PERC S140 uses part of checkpointing are available: • Consistency Check (CC) • Background Initialization (BGI) • Rebuild ...
It is recommended that might occur with the redundant data at www.dell.com/openmanagemanuals. Similar to CC, BGI helps the controller to the secondary physical disk mirror set. Virtual disk cache policies NOTE: Configuring virtual... periodically run a consistency check on NVMe PCIe SSD is corrected, the data on the primary physical disk in the BIOS configuration utility, accessed using OpenManage Server Administrator Storage Management. The PERC S140 uses part of checkpointing are available: • Consistency Check (CC) • Background Initialization (BGI) • Rebuild ...
EMC PowerEdge RAID Controller S140 Users Guide
Page 43
...the physical disk write cache policy for NVMe PCIe SSDs are not supported in NVMe in non-RAID mode may cause an extra reboot on a server. Unable to 5.4.1.1 or later. SATA in RAID mode and NVMe in RAID mode. Corrective Action: Third-party drivers for SATA drives section....Description Likely Cause: The system may cause the OS installation to the system (A UPS is recommended). Extra reboot during the OS installation using Dell LifeCycle controller, then the physical disk write cache policy is constant power supply to fail. NOTE: Ensure that the maximum number of virtual ...
...the physical disk write cache policy for NVMe PCIe SSDs are not supported in NVMe in non-RAID mode may cause an extra reboot on a server. Unable to 5.4.1.1 or later. SATA in RAID mode and NVMe in RAID mode. Corrective Action: Third-party drivers for SATA drives section....Description Likely Cause: The system may cause the OS installation to the system (A UPS is recommended). Extra reboot during the OS installation using Dell LifeCycle controller, then the physical disk write cache policy is constant power supply to fail. NOTE: Ensure that the maximum number of virtual ...
EMC PowerEdge RAID Controller S140 Users Guide
Page 44
... option to Boot Sequence Retry. WARNING: While switching from the first virtual disk. 44 Troubleshooting your changes and then exit. When the Dell POST screen is displayed, press F2 to access the system BIOS configuration utility. 2. Check for a bootable virtual disk 1. In the system ...Configuration Utility Ctrl+R list after a system reboot NOTE: When booting from a Non-RAID virtual disk, creating a virtual disk in OpenManage Server Administrator changes the virtual disk order and displaces the bootable Non-RAID virtual disk from the drives beyond the first 10 drives listed in the...
... option to Boot Sequence Retry. WARNING: While switching from the first virtual disk. 44 Troubleshooting your changes and then exit. When the Dell POST screen is displayed, press F2 to access the system BIOS configuration utility. 2. Check for a bootable virtual disk 1. In the system ...Configuration Utility Ctrl+R list after a system reboot NOTE: When booting from a Non-RAID virtual disk, creating a virtual disk in OpenManage Server Administrator changes the virtual disk order and displaces the bootable Non-RAID virtual disk from the drives beyond the first 10 drives listed in the...
EMC PowerEdge RAID Controller S140 Users Guide
Page 45
...Ctrl+R option does not display if the PERC S140 mode is set incorrectly at System Setup on page 44 Configuring RAID using OpenManage Server Administrator Storage Management. Press Enter to allow the operating system to continue with NVMe PCIe SSD(s). Check the status at least one ... 5, a single physical disk failure causes a Degraded status. -For a virtual disk at system startup, press Ctrl+R to enter setup ---. Warning Messages The Dell Inc. For the virtual disk to boot. When prompted at RAID 10, the failure of a physical disk in Normal or Ready status before a system boot...
...Ctrl+R option does not display if the PERC S140 mode is set incorrectly at System Setup on page 44 Configuring RAID using OpenManage Server Administrator Storage Management. Press Enter to allow the operating system to continue with NVMe PCIe SSD(s). Check the status at least one ... 5, a single physical disk failure causes a Degraded status. -For a virtual disk at system startup, press Ctrl+R to enter setup ---. Warning Messages The Dell Inc. For the virtual disk to boot. When prompted at RAID 10, the failure of a physical disk in Normal or Ready status before a system boot...
EMC PowerEdge RAID Controller S140 Users Guide
Page 46
... source. • Determine if two or more physical disks in a redundant virtual disk have only one or more number of NVMe drives is connected to a server having less number of cores, then there is a lack of resources to investigate the cause of the physical disks have failed. To investigate the cause... Ctrl+R to service the NVMe and BSOD can occur. Other errors appearing on the BIOS screen BSOD is observed while booting on the NVMe configuration server Description: NVMe drives utilize the system resources, if more of the Degraded and Failed virtual disks.
... source. • Determine if two or more physical disks in a redundant virtual disk have only one or more number of NVMe drives is connected to a server having less number of cores, then there is a lack of resources to investigate the cause of the physical disks have failed. To investigate the cause... Ctrl+R to service the NVMe and BSOD can occur. Other errors appearing on the BIOS screen BSOD is observed while booting on the NVMe configuration server Description: NVMe drives utilize the system resources, if more of the Degraded and Failed virtual disks.
EMC PowerEdge RAID Controller S140 Users Guide
Page 48
...installed. A physical disk is : 1. Only physical disks that it is not working on PowerEdge R740 Description The Blink task allows you update the NVMe PCIe SSD firmware using Dell Update Package or DUP Likely Cause: The supported device driver for the operating system available on...a physical disk Check whether or not the physical disk is highlighted red at the BIOS Configuration Utility or Ctrl R 1. Install Open Manage Server Administrator management utility version 8.0 (or higher). Third-party drivers for NVMe PCIe SSD may fail. Check if the Physical Disk might be ...
...installed. A physical disk is : 1. Only physical disks that it is not working on PowerEdge R740 Description The Blink task allows you update the NVMe PCIe SSD firmware using Dell Update Package or DUP Likely Cause: The supported device driver for the operating system available on...a physical disk Check whether or not the physical disk is highlighted red at the BIOS Configuration Utility or Ctrl R 1. Install Open Manage Server Administrator management utility version 8.0 (or higher). Third-party drivers for NVMe PCIe SSD may fail. Check if the Physical Disk might be ...
EMC Systems Management Overview Guide Version 20.0
Page 3
... to help manage the PowerEdge servers. Dell EMC systems management 3 Dell EMC has connected or integrated the advanced management capabilities of Dell hardware into the hardware and firmware architecture for managing Dell EMC PowerEdge servers are faced by many console to manage your Dell EMC servers ○ Built-in tools that is to completely manage Dell EMC PowerEdge servers. OpenManage Enterprise helps the...
... to help manage the PowerEdge servers. Dell EMC systems management 3 Dell EMC has connected or integrated the advanced management capabilities of Dell hardware into the hardware and firmware architecture for managing Dell EMC PowerEdge servers are faced by many console to manage your Dell EMC servers ○ Built-in tools that is to completely manage Dell EMC PowerEdge servers. OpenManage Enterprise helps the...
EMC Systems Management Overview Guide Version 20.0
Page 4
... APIs • RACADM CLI • GitHub Scripting Libraries Integration with third-party consoles • Dell EMC Server Deployment Pack for Microsoft System Center Configuration Manager (SCCM) • Dell EMC Server PRO Management Pack for Microsoft System Center Virtual Machine Manager (SCVMM) • Dell EMC Server Management Pack Suite for Microsoft System Center Operations Manager (SCOM) •...
... APIs • RACADM CLI • GitHub Scripting Libraries Integration with third-party consoles • Dell EMC Server Deployment Pack for Microsoft System Center Configuration Manager (SCCM) • Dell EMC Server PRO Management Pack for Microsoft System Center Virtual Machine Manager (SCVMM) • Dell EMC Server Management Pack Suite for Microsoft System Center Operations Manager (SCOM) •...