Dell PowerEdge Systems 6350 Service Manual
Page 10
...and a power-supply paralleling board (PSPB). Three peer-to-peer PCI expansion subsystems. A VGA-compatible video subsystem with the PowerEdge Expandable RAID controller. A National Semiconductor PC87309 super I/O controller that support up to three hot-pluggable 1-inch SCSI hard-disk ...shown in Figure 1-1. An Adaptec AIC-7860 Ultra/Narrow SCSI-III host adapter that monitors operation of the PowerEdge 6350 systems. 1-2 Dell PowerEdge 6350 Systems Service Manual Server management circuitry that supports the CD-ROM drive. Four redundant system cooling fans. The backplane supports ...
...and a power-supply paralleling board (PSPB). Three peer-to-peer PCI expansion subsystems. A VGA-compatible video subsystem with the PowerEdge Expandable RAID controller. A National Semiconductor PC87309 super I/O controller that support up to three hot-pluggable 1-inch SCSI hard-disk ...shown in Figure 1-1. An Adaptec AIC-7860 Ultra/Narrow SCSI-III host adapter that monitors operation of the PowerEdge 6350 systems. 1-2 Dell PowerEdge 6350 Systems Service Manual Server management circuitry that supports the CD-ROM drive. Four redundant system cooling fans. The backplane supports ...
Dell PowerEdge Systems 6350 Service Manual
Page 12
lock access panel diskette drive access indicator bezel and hard-disk drive keylock power button CD-ROM drive diskette drive expansion slots (7) parallel port connector external SCSI connectors (optional) (2) AC power receptacle video connector serial port 2 connector serial port 1 connector server management bus (SMB) connectors (2) keyboard connector mouse connector 1-4 Dell PowerEdge 6350 Systems Service Manual
lock access panel diskette drive access indicator bezel and hard-disk drive keylock power button CD-ROM drive diskette drive expansion slots (7) parallel port connector external SCSI connectors (optional) (2) AC power receptacle video connector serial port 2 connector serial port 1 connector server management bus (SMB) connectors (2) keyboard connector mouse connector 1-4 Dell PowerEdge 6350 Systems Service Manual
Dell PowerEdge Systems 6350 Service Manual
Page 14
... the system board, memory board, microprocessors, and expansion cards. right panel door panel door keylock door latches (2) left door. Lift the left panel door 1-6 Dell PowerEdge 6350 Systems Service Manual Two panel doors on the right-side panel door secures both doors properly. The right panel door provides access to open the computer panel doors...
... the system board, memory board, microprocessors, and expansion cards. right panel door panel door keylock door latches (2) left door. Lift the left panel door 1-6 Dell PowerEdge 6350 Systems Service Manual Two panel doors on the right-side panel door secures both doors properly. The right panel door provides access to open the computer panel doors...
Dell PowerEdge Systems 6350 Service Manual
Page 16
... DIMMs to 4 GB by installing combinations of four sockets labeled "DIMM A" through "DIMM D" (see Figure 1-8). it does not matter which bank holds which size. 1-8 Dell PowerEdge 6350 Systems Service Manual and 32-MB DIMMs can be mixed within a memory bank. The memory module provides 16 168-pin DIMM sockets divided into four banks, each other...
... DIMMs to 4 GB by installing combinations of four sockets labeled "DIMM A" through "DIMM D" (see Figure 1-8). it does not matter which bank holds which size. 1-8 Dell PowerEdge 6350 Systems Service Manual and 32-MB DIMMs can be mixed within a memory bank. The memory module provides 16 168-pin DIMM sockets divided into four banks, each other...
Dell PowerEdge Systems 6350 Service Manual
Page 18
... drives are supplied by the SCSI backplane board. SCSI hard-disk drives must be disabled. All Dell PowerEdge 6350 systems have their termination should be set by Dell in special drive carriers that the drive motors wait for the SCSI bus. Configure the drives so...for SCSI hard-disk drives are set to SCSI ID 5, and their termination disabled. The Dell PowerEdge 6350 system includes a PSPB and three 275-W redundant system power supplies. 1-10 Dell PowerEdge 6350 Systems Service Manual Although you can install a mixture of Ultra2/LVD and Ultra hard-disk drives, they ...
... drives are supplied by the SCSI backplane board. SCSI hard-disk drives must be disabled. All Dell PowerEdge 6350 systems have their termination should be set by Dell in special drive carriers that the drive motors wait for the SCSI bus. Configure the drives so...for SCSI hard-disk drives are set to SCSI ID 5, and their termination disabled. The Dell PowerEdge 6350 system includes a PSPB and three 275-W redundant system power supplies. 1-10 Dell PowerEdge 6350 Systems Service Manual Although you can install a mixture of Ultra2/LVD and Ultra hard-disk drives, they ...
Dell PowerEdge Systems 6350 Service Manual
Page 20
... and distributes it to the power supplies. For information on -5 VDC and -12 VDC outputs cannot exceed 0.6 A. The PSPB receives input from the PSPB. 1-12 Dell PowerEdge 6350 Systems Service Manual monitoring voltage and current outputs from the power supplies, voltage going to connectors on the PSPB when they are installed. . 1 +3.3 VDC +3.23 to +3.46...
... and distributes it to the power supplies. For information on -5 VDC and -12 VDC outputs cannot exceed 0.6 A. The PSPB receives input from the PSPB. 1-12 Dell PowerEdge 6350 Systems Service Manual monitoring voltage and current outputs from the power supplies, voltage going to connectors on the PSPB when they are installed. . 1 +3.3 VDC +3.23 to +3.46...
Dell PowerEdge Systems 6350 Service Manual
Page 22
... 13 14 common (black) +5 VL (red) PRES_DET (gray) +5 VL (red) common (black) +3.3 VL (orange) 12C_ALRT_EXT# (gray) 1 23 45 6 7 PLANAR_ID (gray) I2C_SCL_EXT (gray) I2C_SDA_EXT (gray) 1-14 Dell PowerEdge 6350 Systems Service Manual +5 VL (red) -5 VL (white) +5 VL (red) +5 VL (red) common (black) common (black) NC_TFSC (gray) +5 VL (red) common (black) SYS_PS_ON #1 (gray) +3.3 VL (orange) common (black...
... 13 14 common (black) +5 VL (red) PRES_DET (gray) +5 VL (red) common (black) +3.3 VL (orange) 12C_ALRT_EXT# (gray) 1 23 45 6 7 PLANAR_ID (gray) I2C_SCL_EXT (gray) I2C_SDA_EXT (gray) 1-14 Dell PowerEdge 6350 Systems Service Manual +5 VL (red) -5 VL (white) +5 VL (red) +5 VL (red) common (black) common (black) NC_TFSC (gray) +5 VL (red) common (black) SYS_PS_ON #1 (gray) +3.3 VL (orange) common (black...
Dell PowerEdge Systems 6350 Service Manual
Page 24
19 1 20 2 1 FAN_2-VCC 11 GROUND 2 FAN_TRAY_ID_1 12 FAN_3_TACH 3 FAN_2_TACH 13 Reserved 4 FAN_1_VCC 14 GROUND 5 GROUND 15 Reserved 6 FAN_1_TACH 16 Reserved 7 FAN_4_VCC 17 GROUND 8 GROUND 18 Reserved 9 FAN_4_TACH 19 FAN_TRAY_ID_2 10 FAN_3_VCC 20 GROUND 24 19 B5 B1 A1 A3 61 1-16 Dell PowerEdge 6350 Systems Service Manual
19 1 20 2 1 FAN_2-VCC 11 GROUND 2 FAN_TRAY_ID_1 12 FAN_3_TACH 3 FAN_2_TACH 13 Reserved 4 FAN_1_VCC 14 GROUND 5 GROUND 15 Reserved 6 FAN_1_TACH 16 Reserved 7 FAN_4_VCC 17 GROUND 8 GROUND 18 Reserved 9 FAN_4_TACH 19 FAN_TRAY_ID_2 10 FAN_3_VCC 20 GROUND 24 19 B5 B1 A1 A3 61 1-16 Dell PowerEdge 6350 Systems Service Manual
Dell PowerEdge Systems 6350 Service Manual
Page 26
... input connector (POWER1) power input connector (POWER2) diskette drive interface connector (FLOPPY) power input connector (POWER3) Dell Remote Assistant Card connector (SVR_MGT) front of important system board components. The subsections that follow provide service-related information about the system board components. Figure 1-19 illustrates the location of system board Ultra2/LVD...(VGA) memory board connector (MEMORY_BD) 32-bit PCI connectors (PCI1 [top] through PCI3) 64-bit PCI connectors (PCI4 through PCI7) battery connector (BATTERY) 1-18 Dell PowerEdge 6350 Systems Service Manual
... input connector (POWER1) power input connector (POWER2) diskette drive interface connector (FLOPPY) power input connector (POWER3) Dell Remote Assistant Card connector (SVR_MGT) front of important system board components. The subsections that follow provide service-related information about the system board components. Figure 1-19 illustrates the location of system board Ultra2/LVD...(VGA) memory board connector (MEMORY_BD) 32-bit PCI connectors (PCI1 [top] through PCI3) 64-bit PCI connectors (PCI4 through PCI7) battery connector (BATTERY) 1-18 Dell PowerEdge 6350 Systems Service Manual
Dell PowerEdge Systems 6350 Service Manual
Page 28
Warning: Firmware is out-of-date, 1-20 Dell PowerEdge 6350 Systems Service Manual please update...
Warning: Firmware is out-of-date, 1-20 Dell PowerEdge 6350 Systems Service Manual please update...
Dell PowerEdge Systems 6350 Service Manual
Page 30
... port Used by the diskette drive controller Used by the primary parallel port Used by the RTC Used for power management functions Available Available 1-22 Dell PowerEdge 6350 Systems Service Manual Reserved for future microprocessor speed. PASSWD CARDBIOS ISA_CLR RSVD1 RSVD2 350MHZ 400MHZ 450MHZ 500MHZ Installed (default) to remove an existing password. Installed only if...
... port Used by the diskette drive controller Used by the primary parallel port Used by the RTC Used for power management functions Available Available 1-22 Dell PowerEdge 6350 Systems Service Manual Reserved for future microprocessor speed. PASSWD CARDBIOS ISA_CLR RSVD1 RSVD2 350MHZ 400MHZ 450MHZ 500MHZ Installed (default) to remove an existing password. Installed only if...
Dell PowerEdge Systems 6350 Service Manual
Page 32
... (16) 168-pin sockets 32-, 64 (when available), 128-, and 256-MB buffered EDO 128 MB (minimum) 4 GB F000:0000h-F000:FFFFh none 1-24 Dell PowerEdge 6350 Systems Service Manual higher internal speeds when available, all with 100-MHz external speeds 512-KB or 1-MB L2 cache; 2-MB L2 cache available for microprocessors with speeds...
... (16) 168-pin sockets 32-, 64 (when available), 128-, and 256-MB buffered EDO 128 MB (minimum) 4 GB F000:0000h-F000:FFFFh none 1-24 Dell PowerEdge 6350 Systems Service Manual higher internal speeds when available, all with 100-MHz external speeds 512-KB or 1-MB L2 cache; 2-MB L2 cache available for microprocessors with speeds...
Dell PowerEdge Systems 6350 Service Manual
Page 34
... connector 2 MB (not upgradable) DC power supply: Wattage Voltage Backup battery 275 W per supply 90-265 V at 47-63 Hz 3.0-V CR2032 lithium coin cell 1-26 Dell PowerEdge 6350 Systems Service Manual
... connector 2 MB (not upgradable) DC power supply: Wattage Voltage Backup battery 275 W per supply 90-265 V at 47-63 Hz 3.0-V CR2032 lithium coin cell 1-26 Dell PowerEdge 6350 Systems Service Manual
Dell PowerEdge Systems 6350 Service Manual
Page 38
... a video expansion card, and also to determine if he or she is making an error, such as to the appropriate user documentation for the monitor. 2-2 Dell PowerEdge 6350 Systems Service Manual
... a video expansion card, and also to determine if he or she is making an error, such as to the appropriate user documentation for the monitor. 2-2 Dell PowerEdge 6350 Systems Service Manual
Dell PowerEdge Systems 6350 Service Manual
Page 40
... a series of these indicators flash on and off within approximately 10 seconds after the boot routine starts? Proceed to the next section, "Internal Visual Inspection." 2-4 Dell PowerEdge 6350 Systems Service Manual Troubleshoot the system power supplies. System error messages: These messages can indicate problems or provide status information. No. Yes. Proceed to step 4. Watch the...
... a series of these indicators flash on and off within approximately 10 seconds after the boot routine starts? Proceed to the next section, "Internal Visual Inspection." 2-4 Dell PowerEdge 6350 Systems Service Manual Troubleshoot the system power supplies. System error messages: These messages can indicate problems or provide status information. No. Yes. Proceed to step 4. Watch the...
Dell PowerEdge Systems 6350 Service Manual
Page 42
...5, "Using the Resource Configuration Utility," in the User's Guide or "Interrupt Assignments" and "DMA Channel Assignments" in this manual. To start the Dell Diagnostics, turn off the system, insert a diagnostics diskette into drive A, and then turn them on the screen telling you ...must be resolved? No further steps are firmly attached to be allocated during installation of which DIMM has failed. 2-6 Dell PowerEdge 6350 Systems Service Manual Devices within the computer may be installed at different times, it is possible that aid in disorderly or erratic system ...
...5, "Using the Resource Configuration Utility," in the User's Guide or "Interrupt Assignments" and "DMA Channel Assignments" in this manual. To start the Dell Diagnostics, turn off the system, insert a diagnostics diskette into drive A, and then turn them on the screen telling you ...must be resolved? No further steps are firmly attached to be allocated during installation of which DIMM has failed. 2-6 Dell PowerEdge 6350 Systems Service Manual Devices within the computer may be installed at different times, it is possible that aid in disorderly or erratic system ...
Dell PowerEdge Systems 6350 Service Manual
Page 46
... 64 KB of main memory 1-4-2 Parity failure in the first 64 KB of main memory 2-1-1 Bit failure in the first 64 KB of main 2-4-4 memory 3-2 Dell PowerEdge 6350 Systems Service Manual No memory installed Remove and reseat the DIMMs. Reboot the system. 1-1-3 1-1-4 1-2-1 NVRAM write/read failure Main-memory refresh verification failure Remove and reseat the...
... 64 KB of main memory 1-4-2 Parity failure in the first 64 KB of main memory 2-1-1 Bit failure in the first 64 KB of main 2-4-4 memory 3-2 Dell PowerEdge 6350 Systems Service Manual No memory installed Remove and reseat the DIMMs. Reboot the system. 1-1-3 1-1-4 1-2-1 NVRAM write/read failure Main-memory refresh verification failure Remove and reseat the...
Dell PowerEdge Systems 6350 Service Manual
Page 48
4-3-3 4-3-4 4-4-1 4-4-2 4-4-3 4-4-4 Defective system board Time-of-day clock stopped Faulty I/O chip Super I/O controller failure Parallel-port test failure (defective system board) Math coprocessor failure (defective microprocessor) Cache test failure (defective microprocessor) Replace the system board. Replace the battery. Replace the microprocessor. 3-4 Dell PowerEdge 6350 Systems Service Manual If the problem persists, replace the system board. Replace the system board. Replace the microprocessor. Replace the system board.
4-3-3 4-3-4 4-4-1 4-4-2 4-4-3 4-4-4 Defective system board Time-of-day clock stopped Faulty I/O chip Super I/O controller failure Parallel-port test failure (defective system board) Math coprocessor failure (defective microprocessor) Cache test failure (defective microprocessor) Replace the system board. Replace the battery. Replace the microprocessor. 3-4 Dell PowerEdge 6350 Systems Service Manual If the problem persists, replace the system board. Replace the system board. Replace the microprocessor. Replace the system board.
Dell PowerEdge Systems 6350 Service Manual
Page 50
... does not resolve the problem, remove and reseat the DIMMs and then the memory module. If the problem still persists, replace the system board. 3-6 Dell PowerEdge 6350 Systems Service Manual Replace the system board. Move the write-protect tab on the diskette. If the problem persists, replace the DIMMs or the memory module. Reinsert or...
... does not resolve the problem, remove and reseat the DIMMs and then the memory module. If the problem still persists, replace the system board. 3-6 Dell PowerEdge 6350 Systems Service Manual Replace the system board. Move the write-protect tab on the diskette. If the problem persists, replace the DIMMs or the memory module. Reinsert or...
Dell PowerEdge Systems 6350 Service Manual
Page 52
...) Check the keyboard cable connection. If the problem persists, replace the expansion card. Replace the keyboard. If the problem persists, replace the system board. 3-8 Dell PowerEdge 6350 Systems Service Manual Replace the keyboard. I/O parity interrupt at address Keyboard clock line failure Keyboard failure Keyboard controller failure Keyboard data line failure Keyboard stuck key failure Expansion...
...) Check the keyboard cable connection. If the problem persists, replace the expansion card. Replace the keyboard. If the problem persists, replace the system board. 3-8 Dell PowerEdge 6350 Systems Service Manual Replace the keyboard. I/O parity interrupt at address Keyboard clock line failure Keyboard failure Keyboard controller failure Keyboard data line failure Keyboard stuck key failure Expansion...