Command Line Interface Guide
Page 1164
... port must be active and working in Privileged EXEC mode to display the estimated copper cable length attached to all ports. The full syntax is unit / port. console#show copper-ports cable-length [interface] • interface - Syntax show copper-ports cable-length Port Length [meters] ---- 1/g1 Example The following example displays the estimated copper...
... port must be active and working in Privileged EXEC mode to display the estimated copper cable length attached to all ports. The full syntax is unit / port. console#show copper-ports cable-length [interface] • interface - Syntax show copper-ports cable-length Port Length [meters] ---- 1/g1 Example The following example displays the estimated copper...
Command Line Interface Guide
Page 1165
The full syntax is 120 meters. Example The following example displays the last TDR tests on all ports. console#show copper-ports tdr [interface] • interface - Default Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines The ...copper-related commands do not apply to the stacking, CX-4, or 10GBaseT ports associated with these plug-in modules. The maximum length of the cable for the Time Domain Reflectometry (TDR) test is unit / port. Syntax show copper-ports tdr Port Result Length [meters] Date 1/g1 OK 1/g2 ...
The full syntax is 120 meters. Example The following example displays the last TDR tests on all ports. console#show copper-ports tdr [interface] • interface - Default Configuration This command has no default configuration. Command Mode Privileged EXEC mode User Guidelines The ...copper-related commands do not apply to the stacking, CX-4, or 10GBaseT ports associated with these plug-in modules. The maximum length of the cable for the Time Domain Reflectometry (TDR) test is unit / port. Syntax show copper-ports tdr Port Result Length [meters] Date 1/g1 OK 1/g2 ...
Command Line Interface Guide
Page 1167
... open at 64 meters PHY Diagnostics Commands 1167 Loss of a copper cable attached to port 1/g3. Measured TX output power in a report on the cable attached to a port. Default Configuration This command has no default configuration. console#test copper-port tdr 1/g3 Cable is 120 meters. The full syntax is a combo port with Time...
... open at 64 meters PHY Diagnostics Commands 1167 Loss of a copper cable attached to port 1/g3. Measured TX output power in a report on the cable attached to a port. Default Configuration This command has no default configuration. console#test copper-port tdr 1/g3 Cable is 120 meters. The full syntax is a combo port with Time...
Command Line Interface Guide
Page 1168
The following example results in a failure to report on fiber ports 1168 PHY Diagnostics Commands console#test copper-port tdr 2/g3 Can't perform the test on the cable attached to port 2/g3.
The following example results in a failure to report on fiber ports 1168 PHY Diagnostics Commands console#test copper-port tdr 2/g3 Can't perform the test on the cable attached to port 2/g3.
User's Guide
Page 4
Device Management Buttons 44 Check Boxes 45 Defining Fields 45 Accessing the Switch Through the CLI 45 Console Connection 46 Telnet Connection 46 Using the CLI 46 Command Mode Overview 46 User EXEC Mode 47 Privileged EXEC Mode 47 Global Configuration Mode 48 Interface Configuration Mode 48 3 Cable and Port Information Overview 49 Ethernet Interface 50 SFP Interfaces 51 Bay 1 and Bay 2 Interfaces 52 Serial Cable Connection 52 Connecting the Switch to a Terminal 52 4
Device Management Buttons 44 Check Boxes 45 Defining Fields 45 Accessing the Switch Through the CLI 45 Console Connection 46 Telnet Connection 46 Using the CLI 46 Command Mode Overview 46 User EXEC Mode 47 Privileged EXEC Mode 47 Global Configuration Mode 48 Interface Configuration Mode 48 3 Cable and Port Information Overview 49 Ethernet Interface 50 SFP Interfaces 51 Bay 1 and Bay 2 Interfaces 52 Serial Cable Connection 52 Connecting the Switch to a Terminal 52 4
User's Guide
Page 45
...2-4. Removes the selected item. All characters may be managed over a direct connection to the console port or through a Telnet connection, ensure the device has an IP address defined and that takes... you are managing a stack, ensure the serial interface cable is similar to the Master switch of log files, select match criteria for the ... prior to a configuration page. Using the CLI is attached to entering commands on the Dell OpenManage Switch Administrator Web page. Check Boxes Check Box Type Add Remove General selection Description ...
...2-4. Removes the selected item. All characters may be managed over a direct connection to the console port or through a Telnet connection, ensure the device has an IP address defined and that takes... you are managing a stack, ensure the serial interface cable is similar to the Master switch of log files, select match criteria for the ... prior to a configuration page. Using the CLI is attached to entering commands on the Dell OpenManage Switch Administrator Web page. Check Boxes Check Box Type Add Remove General selection Description ...
User's Guide
Page 46
...the enable password is the User EXEC mode. In each mode, a specific command is configured on page 52 for a description of the required console cable. 1. Only a limited subset of commands are installing a stack of commands available for more information on the switch (or stack) and wait until... the startup is powered up enable passwords. 46 Using Dell™ OpenManage™ Switch Administrator When a stack is complete. The console# prompt now displays. 5. All CLI commands can be used to navigate from one command mode to ...
...the enable password is the User EXEC mode. In each mode, a specific command is configured on page 52 for a description of the required console cable. 1. Only a limited subset of commands are installing a stack of commands available for more information on the switch (or stack) and wait until... the startup is powered up enable passwords. 46 Using Dell™ OpenManage™ Switch Administrator When a stack is complete. The console# prompt now displays. 5. All CLI commands can be used to navigate from one command mode to ...
User's Guide
Page 51
Figure 3-2 illustrates an SFP connector. Figure 3-2. SFP Interfaces SFP interfaces are on the console front. SFP Connector Cable and Port Information 51
Figure 3-2 illustrates an SFP connector. Figure 3-2. SFP Interfaces SFP interfaces are on the console front. SFP Connector Cable and Port Information 51
User's Guide
Page 52
... Connector to the switch's serial port. 3. Connect the serial cable to Console 52 Cable and Port Information If you are configuring a stack, connect the interface cable to a Terminal 1. Connecting the Switch to the serial port of the Master switch. Bay 1 and Bay 2 Interfaces The Dell™ PowerConnect™ 6200series switches support dual 10 Gb slot interfaces...
... Connector to the switch's serial port. 3. Connect the serial cable to Console 52 Cable and Port Information If you are configuring a stack, connect the interface cable to a Terminal 1. Connecting the Switch to the serial port of the Master switch. Bay 1 and Bay 2 Interfaces The Dell™ PowerConnect™ 6200series switches support dual 10 Gb slot interfaces...
User's Guide
Page 61
... is used only for the first time, the switches elect a Master Switch, which may occupy any location in the stack. NOTE: The console port supports asynchronous data of switches, you need to use the CLI. Connect the terminal to an EIA/TIA-232 port. Physical Dimensions The... H). The default baud rate is powered up and configuring it. Console (RS-232) Port The console (RS-232) port is used to access the CLI from a console terminal connected to the Master Switch. NOTE: If you will not be able to assemble and cable the stack before powering up for management through a serial interface...
... is used only for the first time, the switches elect a Master Switch, which may occupy any location in the stack. NOTE: The console port supports asynchronous data of switches, you need to use the CLI. Connect the terminal to an EIA/TIA-232 port. Physical Dimensions The... H). The default baud rate is powered up and configuring it. Console (RS-232) Port The console (RS-232) port is used to access the CLI from a console terminal connected to the Master Switch. NOTE: If you will not be able to assemble and cable the stack before powering up for management through a serial interface...
User's Guide
Page 74
...(or emulation) connected to the serial port (cross-cable) in the rear of the unit • Assigned IP address for the switch for changing the default baud rate using CLI commands: console#configure console(config)#line console console(config-line)#speed 115200 NOTE: Remember to set the ... Information The PowerConnect 6200 Series switches are used to define the relationship of the switch to its unique network topology. The configuration process consists of adjusting the ASCII configuration files so that are delivered with Telnet, SSH, and so forth 74 Configuring Dell PowerConnect
...(or emulation) connected to the serial port (cross-cable) in the rear of the unit • Assigned IP address for the switch for changing the default baud rate using CLI commands: console#configure console(config)#line console console(config-line)#speed 115200 NOTE: Remember to set the ... Information The PowerConnect 6200 Series switches are used to define the relationship of the switch to its unique network topology. The configuration process consists of adjusting the ASCII configuration files so that are delivered with Telnet, SSH, and so forth 74 Configuring Dell PowerConnect
User's Guide
Page 105
...and the switch rebooted. A browser application • One Null Modem F2F cable • Straight or cross UTP (category 5) cable(s) Initial Connection 1. which is the configuration of this example: • PowerConnect 6200 Series switch • A workstation with the switch. See "Device ...network management connection with the following settings and select the appropriate COM port. Set the serial console with the default configuration and definitions. Configuring Dell PowerConnect 105 This section does not explain the various configurations available on the switch or the relevant...
...and the switch rebooted. A browser application • One Null Modem F2F cable • Straight or cross UTP (category 5) cable(s) Initial Connection 1. which is the configuration of this example: • PowerConnect 6200 Series switch • A workstation with the switch. See "Device ...network management connection with the following settings and select the appropriate COM port. Set the serial console with the default configuration and definitions. Configuring Dell PowerConnect 105 This section does not explain the various configurations available on the switch or the relevant...
User's Guide
Page 111
...console# 01-Jan-2000 01:43:03 %LINK-I-Up: Vlan 1 01-Jan-2000 01:43:03 %LINK-I-Up: 1/xg1 01-Jan-2000 01:43:34 %STP-I-PORTSTATUS: Port 1/xg1: STP status Forwarding Configuring Dell PowerConnect... 111 Enter the enable command at the privileged mode prompt (#), and reboot the device. it is forwarding (after 30 seconds), as follows: console>enable console# 2. Enabling Remote Management 1. console> console>enable console#delete startup-config Startup file was deleted console.... Ensure (on the serial console) that the interface status changed to the switch, using a CAT5...
...console# 01-Jan-2000 01:43:03 %LINK-I-Up: Vlan 1 01-Jan-2000 01:43:03 %LINK-I-Up: 1/xg1 01-Jan-2000 01:43:34 %STP-I-PORTSTATUS: Port 1/xg1: STP status Forwarding Configuring Dell PowerConnect... 111 Enter the enable command at the privileged mode prompt (#), and reboot the device. it is forwarding (after 30 seconds), as follows: console>enable console# 2. Enabling Remote Management 1. console> console>enable console#delete startup-config Startup file was deleted console.... Ensure (on the serial console) that the interface status changed to the switch, using a CAT5...
Getting Started Guide
Page 12
... serial port (serial port 1 or serial port 2) to connect to assemble and cable the stack before proceeding. You can download the release notes from the Dell Support website at support.dell.com. Perform the following is required to use the console port on Windows 2000 service packs. 10 Getting Started Guide Connecting the Terminal...
... serial port (serial port 1 or serial port 2) to connect to assemble and cable the stack before proceeding. You can download the release notes from the Dell Support website at support.dell.com. Perform the following is required to use the console port on Windows 2000 service packs. 10 Getting Started Guide Connecting the Terminal...
Getting Started Guide
Page 13
... stack. If POST detects a critical problem, the program flow stops. POST messages are installing a stack of the RS-232 crossover cable directly to the switch console port, and tighten the captive retaining bolts. Figure 1-4. If you connect the terminal to a member switch, you are displayed on ... a power-on the rear panel as shown in the array on the terminal and indicate test success or failure. The PowerConnect 6200 series console ports are located on selftest (POST). When a stack is loaded into RAM. When the power is fully operational before completely booting.
... stack. If POST detects a critical problem, the program flow stops. POST messages are installing a stack of the RS-232 crossover cable directly to the switch console port, and tighten the captive retaining bolts. Figure 1-4. If you connect the terminal to a member switch, you are displayed on ... a power-on the rear panel as shown in the array on the terminal and indicate test success or failure. The PowerConnect 6200 series console ports are located on selftest (POST). When a stack is loaded into RAM. When the power is fully operational before completely booting.
Release Notes
Page 34
.... indicates the beginning of Release Notes 32 System Firmware Version 3.2.0.6 All characters following the '!' File Management Description Error displayed on console while applying configuration for a port to a 24 port switch. Cable Diagnostics Description Cable Length Diagnostic shows result as a comment. will be treated as 'Unknown' for a 48 port switch to which do not...
.... indicates the beginning of Release Notes 32 System Firmware Version 3.2.0.6 All characters following the '!' File Management Description Error displayed on console while applying configuration for a port to a 24 port switch. Cable Diagnostics Description Cable Length Diagnostic shows result as a comment. will be treated as 'Unknown' for a 48 port switch to which do not...
Configuration Guide
Page 26
... Ports console#test copper-port tdr 1/g1 Cable Status Short Cable Length 5m console#show copper-ports cable-length command in Privileged EXEC mode to display the estimated copper cable length attached to all ports. or (q)uit NOTE: You can also run a cable test using the Web Interface. Example #2: Show Copper Cable Length ... 1/g4 Test has not been performed 1/g5 Test has not been performed --More-- In the navigation tree, click System > Diagnostics. console#show copper-ports cable-length Port Length [meters] ---- 1/g1 The following example displays the estimated copper...
... Ports console#test copper-port tdr 1/g1 Cable Status Short Cable Length 5m console#show copper-ports cable-length command in Privileged EXEC mode to display the estimated copper cable length attached to all ports. or (q)uit NOTE: You can also run a cable test using the Web Interface. Example #2: Show Copper Cable Length ... 1/g4 Test has not been performed 1/g5 Test has not been performed --More-- In the navigation tree, click System > Diagnostics. console#show copper-ports cable-length Port Length [meters] ---- 1/g1 The following example displays the estimated copper...
Configuration Guide
Page 27
...show copper-ports tdr command in Privileged EXEC mode to display the optical transceiver diagnostics. The following example displays the optical transceiver diagnostics. console#show fiber-ports optical-transceiver Port Temp Voltage Current Output Input TX LOS Power Power Fault 1/g3 w OK E OK OK OK ...OK 1/g4 OK OK OK OK OK E OK 1/g1 Copper Temp - Fiber Port Cable Test Example #1: Show Optical Transceiver Diagnostics Use the show fiber ports command is only applicable to display the last Time Domain Reflectometry (TDR) ...
...show copper-ports tdr command in Privileged EXEC mode to display the optical transceiver diagnostics. The following example displays the optical transceiver diagnostics. console#show fiber-ports optical-transceiver Port Temp Voltage Current Output Input TX LOS Power Power Fault 1/g3 w OK E OK OK OK ...OK 1/g4 OK OK OK OK OK E OK 1/g1 Copper Temp - Fiber Port Cable Test Example #1: Show Optical Transceiver Diagnostics Use the show fiber ports command is only applicable to display the last Time Domain Reflectometry (TDR) ...