Command Line Interface Guide
Page 14
... access-class 274 21 PHY Diagnostics Commands 275 test copper-port tdr 275 show copper-ports tdr 275 show copper-ports cable-length 276 show fiber-ports optical-transceiver 277 22 Port Channel Commands 281 interface port-channel 281 interface range port-channel 281 channel-group 282 port-channel load-balance...
... access-class 274 21 PHY Diagnostics Commands 275 test copper-port tdr 275 show copper-ports tdr 275 show copper-ports cable-length 276 show fiber-ports optical-transceiver 277 22 Port Channel Commands 281 interface port-channel 281 interface range port-channel 281 channel-group 282 port-channel load-balance...
Command Line Interface Guide
Page 47
... with TDR (Time Domain Reflectometry) Privileged User technology the quality and characteristics of a copper cable EXEC attached to a port. deny (management) Defines a deny rule. show fiber-ports optical- transceiver Privileged User EXEC Port Channel Commands Command Group interface port-channel interface range portchannel channel-group port-channel loadbalance show copper-ports...
... with TDR (Time Domain Reflectometry) Privileged User technology the quality and characteristics of a copper cable EXEC attached to a port. deny (management) Defines a deny rule. show fiber-ports optical- transceiver Privileged User EXEC Port Channel Commands Command Group interface port-channel interface range portchannel channel-group port-channel loadbalance show copper-ports...
Command Line Interface Guide
Page 72
...-lists. show snmp Displays the SNMP status. show ports storm-control Displays the storm control configuration. show syslog-servers Displays the syslog servers settings. show fiber-ports opticaltransceiver Displays the optical transceiver diagnostics. show users accounts Displays information about the local user database. show tacacs Displays configuration and statistics for a port...
...-lists. show snmp Displays the SNMP status. show ports storm-control Displays the storm control configuration. show syslog-servers Displays the syslog servers settings. show fiber-ports opticaltransceiver Displays the optical transceiver diagnostics. show users accounts Displays information about the local user database. show tacacs Displays configuration and statistics for a port...
Command Line Interface Guide
Page 275
Default Configuration This command has no default configuration. User Guidelines • The port under test should be conducted when the fiber link is 120 meters. PHY Diagnostics Commands 275 NOTE: The maximum distance VCT can function is down. Examples The following example results in a report on ...
Default Configuration This command has no default configuration. User Guidelines • The port under test should be conducted when the fiber link is 120 meters. PHY Diagnostics Commands 275 NOTE: The maximum distance VCT can function is down. Examples The following example results in a report on ...
Command Line Interface Guide
Page 276
...) tests on all ports. Syntax • show copper-ports tdr Port Result ---g1 g2 g3 g4 g5 ------OK Short Test has not been performed Short Fiber Length [meters] -------- Date ----- 50 13:32:00 23 July 2003 128 13:32:00 23 July 2003 - - A valid Ethernet port. show copper-ports cable-length...
...) tests on all ports. Syntax • show copper-ports tdr Port Result ---g1 g2 g3 g4 g5 ------OK Short Test has not been performed Short Fiber Length [meters] -------- Date ----- 50 13:32:00 23 July 2003 128 13:32:00 23 July 2003 - - A valid Ethernet port. show copper-ports cable-length...
Command Line Interface Guide
Page 277
... copper-ports cable-length Port ---g1 g2 g3 Length [meters 50 Giga link not active 110-140 show fiber-ports optical-transceiver The show fiber-ports optical-transceiver [interface] [detailed] • interface - Default Configuration This command has no default configuration.... Ethernet port. • detailed - Command Mode Privileged EXEC mode. PHY Diagnostics Commands 277 Syntax • show fiber-ports optical-transceiver Privileged EXEC mode command displays the optical transceiver diagnostics. Detailed diagnostics. User Guidelines • To test optical transceivers...
... copper-ports cable-length Port ---g1 g2 g3 Length [meters 50 Giga link not active 110-140 show fiber-ports optical-transceiver The show fiber-ports optical-transceiver [interface] [detailed] • interface - Default Configuration This command has no default configuration.... Ethernet port. • detailed - Command Mode Privileged EXEC mode. PHY Diagnostics Commands 277 Syntax • show fiber-ports optical-transceiver Privileged EXEC mode command displays the optical transceiver diagnostics. Detailed diagnostics. User Guidelines • To test optical transceivers...
Command Line Interface Guide
Page 278
console# show fiber-ports optical-transceiver Port Temp Voltage g3 Copper g21 W OK g22 OK OK Current Power ------ Output Power ------ Internally measured supply voltage. Examples The following example displays the optical transceiver diagnostics. Measured TX bias current. Input LOS Power ------ --- Measured TX output power. Input Power - LOS - Current - Loss of signal 278 PHY Diagnostics Commands Voltage - E OK OK OK OK OK OK OK Temp - Internally measured transceiver temperature. Output Power - Measured RX received power.
console# show fiber-ports optical-transceiver Port Temp Voltage g3 Copper g21 W OK g22 OK OK Current Power ------ Output Power ------ Internally measured supply voltage. Examples The following example displays the optical transceiver diagnostics. Measured TX bias current. Input LOS Power ------ --- Measured TX output power. Input Power - LOS - Current - Loss of signal 278 PHY Diagnostics Commands Voltage - E OK OK OK OK OK OK OK Temp - Internally measured transceiver temperature. Output Power - Measured RX received power.
Command Line Interface Guide
Page 279
console# show fiber-ports optical-transceiver detailed Port Temp [C] --- ----g23 70 g21 70 Voltage Current Output Input LOS [Volt] [mA] Power Power [mWatt] [mWatt] --- 7.27 0.79 3.30 2.50 ...
console# show fiber-ports optical-transceiver detailed Port Temp [C] --- ----g23 70 g21 70 Voltage Current Output Input LOS [Volt] [mA] Power Power [mWatt] [mWatt] --- 7.27 0.79 3.30 2.50 ...
User's Guide
Page 13
...back panels. This User Guide contains the information needed for this product. PowerConnect 5448 Front Panel Figure 1-3. The release notes can be downloaded from support.dell.com. There are also four SFP fiber ports that are single ports with two physical connections. When one is connected... the other is disabled. Figure 1-1. PowerConnect 5424 Front Panel Figure 1-2. The combo ports are ...
...back panels. This User Guide contains the information needed for this product. PowerConnect 5448 Front Panel Figure 1-3. The release notes can be downloaded from support.dell.com. There are also four SFP fiber ports that are single ports with two physical connections. When one is connected... the other is disabled. Figure 1-1. PowerConnect 5424 Front Panel Figure 1-2. The combo ports are ...
User's Guide
Page 25
... series systems are configured with even numbers. RJ-45 ports designated as Gigabit ports • Terminal port - PowerConnect 5424 Front Panel The front panel contains ports1-24/48, which is used to an RJ-45 port is a single logical port with two physical ... as Combo ports 21-24/45-48. Designated as 10/100/1000 BaseT Gigabit Ethernet ports • 4 Fiber ports - There are four SFP fiber ports which are marked with the following figure illustrates the PowerConnect 54xx series systems front panel. The upper row of ports are marked by odd numbers and the lower...
... series systems are configured with even numbers. RJ-45 ports designated as Gigabit ports • Terminal port - PowerConnect 5424 Front Panel The front panel contains ports1-24/48, which is used to an RJ-45 port is a single logical port with two physical ... as Combo ports 21-24/45-48. Designated as 10/100/1000 BaseT Gigabit Ethernet ports • 4 Fiber ports - There are four SFP fiber ports which are marked with the following figure illustrates the PowerConnect 54xx series systems front panel. The upper row of ports are marked by odd numbers and the lower...
User's Guide
Page 26
..., software download, etc. The system automatically detects the media used . For general use there is an AC Power Supply connector which is used for various fiber-based modules Only one time. The DC Power Supply connector is connectable to 38400 bps. Device Back Panel On the device back panel are determined... Supply (RPS) to be configured from 2400 bps up to either 110V or 220V power supplies. Console Port Combo Ports A combo port is 9600 bps. PowerConnect Back Panel Port Description The device back panel contains connectors for power, as 1000Base-SX or LX. Figure 2-2.
..., software download, etc. The system automatically detects the media used . For general use there is an AC Power Supply connector which is used for various fiber-based modules Only one time. The DC Power Supply connector is connectable to 38400 bps. Device Back Panel On the device back panel are determined... Supply (RPS) to be configured from 2400 bps up to either 110V or 220V power supplies. Console Port Combo Ports A combo port is 9600 bps. PowerConnect Back Panel Port Description The device back panel contains connectors for power, as 1000Base-SX or LX. Figure 2-2.
User's Guide
Page 100
...-I-Up: g21 01-Jan-2000 01:11:49 :%2SWPHY-I-CHNGCOMBOMEDIA: Media changed from copper media to fiber media (1000BASE-SX) on port g21. 01-Jan-2000 01:11:48 :%2SWPHY-I-CHNGCOMBOMEDIA: Media changed from fiber media to copper media on port g21. 01-Jan-2000 01:11:48 :%LINK-W-Down: g21 01...
...-I-Up: g21 01-Jan-2000 01:11:49 :%2SWPHY-I-CHNGCOMBOMEDIA: Media changed from copper media to fiber media (1000BASE-SX) on port g21. 01-Jan-2000 01:11:48 :%2SWPHY-I-CHNGCOMBOMEDIA: Media changed from fiber media to copper media on port g21. 01-Jan-2000 01:11:48 :%LINK-W-Down: g21 01...
User's Guide
Page 142
... Test for Copper Cables page contains fields for performing virtual cable tests on copper cables. Cables up to pages for performing tests on copper and fiber optics cables. The following table summarizes the equivalent CLI commands for setting fields displayed in the tree view. Status ------ ARP Settings CLI Commands CLI Command...
... Test for Copper Cables page contains fields for performing virtual cable tests on copper cables. Cables up to pages for performing tests on copper and fiber optics cables. The following table summarizes the equivalent CLI commands for setting fields displayed in the tree view. Status ------ ARP Settings CLI Commands CLI Command...
User's Guide
Page 143
...the Integrated Cable Test for Copper Cables • Port - Possible values are: - A short has occurred in the tree view. A fiber cable is connected to which the cable is no cable connected to 20 meters. Configuring System Information 143 Integrated Cable Test for Copper Cables ...page, click System→ Diagnostics→ Integrated Cable Test in the cable. - Fiber Cable - exception of up to the port. - The port to the port. • Cable Fault Distance - The cable passed the test...
...the Integrated Cable Test for Copper Cables • Port - Possible values are: - A short has occurred in the tree view. A fiber cable is connected to which the cable is no cable connected to 20 meters. Configuring System Information 143 Integrated Cable Test for Copper Cables ...page, click System→ Diagnostics→ Integrated Cable Test in the cable. - Fiber Cable - exception of up to the port. - The port to the port. • Cable Fault Distance - The cable passed the test...
User's Guide
Page 145
... transmission. • Loss of Signal - Viewing Optical Transceiver Diagnostics The Optical Transceiver Diagnostics page contains fields for performing tests on Fiber Optic cables. The voltage at which the cable is transmitted. • Input Power - Optical Transceiver Diagnostics • Port - The rate... at which the fiber cable is operating. • Current - The temperature (in the cable. • Data Ready - Figure 6-48. To open the Optical...
... transmission. • Loss of Signal - Viewing Optical Transceiver Diagnostics The Optical Transceiver Diagnostics page contains fields for performing tests on Fiber Optic cables. The voltage at which the cable is transmitted. • Input Power - Optical Transceiver Diagnostics • Port - The rate... at which the fiber cable is operating. • Current - The temperature (in the cable. • Data Ready - Figure 6-48. To open the Optical...
User's Guide
Page 146
...supply voltage. • Current - Not Available, N/S - Performing Fiber Optic Cable Tests Using CLI Commands The following columns: • Temp - Fiber Optic Cable Test CLI Commands CLI Command show fiber-ports optical-transceiver [interface][detailed] Description Displays the optical transceiver ...the following table summarizes the equivalent CLI command for performing fiber optic cable tests. Loss of signal. • Data Ready - Internally measured transceiver temperature. • Voltage - Not Supported, W - Fiber Optic analysis feature works only on SFPs that support ...
...supply voltage. • Current - Not Available, N/S - Performing Fiber Optic Cable Tests Using CLI Commands The following columns: • Temp - Fiber Optic Cable Test CLI Commands CLI Command show fiber-ports optical-transceiver [interface][detailed] Description Displays the optical transceiver ...the following table summarizes the equivalent CLI command for performing fiber optic cable tests. Loss of signal. • Data Ready - Internally measured transceiver temperature. • Voltage - Not Supported, W - Fiber Optic analysis feature works only on SFPs that support ...
User's Guide
Page 147
... subnets. Measured TX output power. Measured RX received power. Internally measured transceiver temperature. Transmitter fault LOS - Loss of the CLI command: console> enable Console# show fiber-ports optical-transceiver Power Port Temp Voltage Current Output Input TX LOS (C) (Volt) (mA) (mWatt) (mWatt) Fault 21 W OK OK 22 OK OK OK 23...
... subnets. Measured TX output power. Measured RX received power. Internally measured transceiver temperature. Transmitter fault LOS - Loss of the CLI command: console> enable Console# show fiber-ports optical-transceiver Power Port Temp Voltage Current Output Input TX LOS (C) (Volt) (mA) (mWatt) (mWatt) Fault 21 W OK OK 22 OK OK OK 23...
User's Guide
Page 351
... same speed, set to full-duplex operations. Ports can be of a previously configured LAG. Aggregated Links are not part of different media types (UTP/Fiber, or different fiber types), provided they operate at the same speed. LACP LAG negotiate Aggregated Port links with other LACP ports located on both static LAGs and...
... same speed, set to full-duplex operations. Ports can be of a previously configured LAG. Aggregated Links are not part of different media types (UTP/Fiber, or different fiber types), provided they operate at the same speed. LACP LAG negotiate Aggregated Port links with other LACP ports located on both static LAGs and...